Blast Furnaces And Steel Mills, major discharger, Seguin, Texas. NPDES permit TX0083178, in force until Sep 11, 2031. Last 12 months: no values over a limit, 1 of 19 reports late. Source: EPA ECHO, Oct 22, 2026.
| Parameter | Statistic | Limit | Months | Outfall |
|---|---|---|---|---|
| Temperature, water deg. fahrenheit | daily maximum | ≤ 105 deg F | all year | 001 |
| Oxygen, dissolved [DO] | monthly minimum | ≥ 4 mg/L | all year | 001 |
| BOD, 5-day, 20 deg. C | daily average | ≤ 10 mg/L | all year | 001 |
| BOD, 5-day, 20 deg. C | daily maximum | ≤ 25 mg/L | all year | 001 |
| pH | minimum | ≥ 6 SU | all year | 001 |
| pH | maximum | ≤ 9 SU | all year | 001 |
| Solids, total suspended | daily average | ≤ 30 lb/d | all year | 001 |
| Solids, total suspended | daily maximum | ≤ 45 lb/d | all year | 001 |
| Oil & Grease | daily average | ≤ 10 lb/d | all year | 001 |
| Oil & Grease | daily maximum | ≤ 15 lb/d | all year | 001 |
| Chloride [as Cl] | daily average | ≤ 430 lb/d | all year | 001 |
| Chloride [as Cl] | daily maximum | ≤ 500 lb/d | all year | 001 |
| Sulfate, total [as SO4] | daily average | ≤ 500 lb/d | all year | 001 |
| Sulfate, total [as SO4] | daily maximum | ≤ 650 lb/d | all year | 001 |
| Cadmium, total [as Cd] | daily maximum | ≤ .05 mg/L | all year | 001 |
| Chromium, total [as Cr] | daily average | ≤ .1 lb/d | all year | 001 |
| Chromium, total [as Cr] | daily maximum | ≤ .2 lb/d | all year | 001 |
| Copper, total [as Cu] | daily average | ≤ .2 lb/d | all year | 001 |
| Copper, total [as Cu] | daily maximum | ≤ .5 lb/d | all year | 001 |
| Lead, total [as Pb] | daily average | ≤ .165 lb/d | all year | 001 |
| Lead, total [as Pb] | daily maximum | ≤ .495 lb/d | all year | 001 |
| Zinc, total [as Zn] | daily average | ≤ .247 lb/d | all year | 001 |
| Zinc, total [as Zn] | daily maximum | ≤ .74 lb/d | all year | 001 |
| Flow, in conduit or thru treatment plant | daily average | ≤ .12 MGD | all year | 001 |
| Flow, in conduit or thru treatment plant | daily maximum | ≤ .18 MGD | all year | 001 |
| Chlorine, total residual | monthly minimum | ≥ 1 mg/L | all year | 001 |
| Chlorine, total residual | monthly maximum | ≤ 4 mg/L | all year | 001 |
| E. coli | daily average | ≤ 126 CFU/100mL | all year | 001 |
| E. coli | daily maximum | ≤ 399 CFU/100mL | all year | 001 |
| Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex | 48-hour minimum | report only (pass=0;fail=1) | all year | TX1 |
| Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex | monthly average minimum | report only (pass=0;fail=1) | all year | TX1 |
| LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas | 48-hour minimum | report only (pass=0;fail=1) | all year | TX1 |
| LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas | monthly average minimum | report only (pass=0;fail=1) | all year | TX1 |
| NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex | 48-hour minimum | report only (%) | all year | TX1 |
| NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex | monthly average minimum | report only (%) | all year | TX1 |
| NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas | 48-hour minimum | report only (%) | all year | TX1 |
| NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas | monthly average minimum | report only (%) | all year | TX1 |
| LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex | 48-hour minimum | report only (%) | all year | TX1 |
| LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex | monthly average minimum | report only (%) | all year | TX1 |
| LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas | 48-hour minimum | report only (%) | all year | TX1 |
| LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas | monthly average minimum | report only (%) | all year | TX1 |
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | single sample | report only (pass=0;fail=1) | all year | TXA |
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | single sample | report only (pass=0;fail=1) | all year | TXA |
Cited limits by parameter: Texas's rules and the federal ones.
Same industry: the 13 Primary Metal Industries permits in Texas.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/TX0083178 · MCP: https://passage-data.com/mcp