Passage Data · Check a report · Use it from your AI
Steel Pipe And Tubes, Conroe, Texas. NPDES permit TX0034681, in force until Sep 6, 2029. Last 12 months: no values over a limit, 4 of 22 reports late. Source: EPA ECHO, Oct 22, 2026.
| Parameter | Statistic | Limit | Months | Outfall |
|---|---|---|---|---|
| Temperature, water deg. fahrenheit | daily maximum | ≤ 95 deg F | all year | 001 |
| Oxygen demand, chem. [high level] [COD] | daily average | ≤ 467 lb/d | all year | 001 |
| Oxygen demand, chem. [high level] [COD] | daily maximum | ≤ 584 lb/d | all year | 001 |
| pH | minimum | ≥ 6 SU | all year | 001 |
| pH | maximum | ≤ 9 SU | all year | 001 |
| Oil & Grease | daily average | ≤ 35 lb/d | all year | 001 |
| Oil & Grease | daily maximum | ≤ 46.7 lb/d | all year | 001 |
| Chloride [as Cl] | daily average | ≤ 235 mg/L | all year | 001 |
| Chloride [as Cl] | daily maximum | ≤ 498 mg/L | all year | 001 |
| Copper, total [as Cu] | daily average | ≤ .0226 lb/d | all year | 001 |
| Copper, total [as Cu] | daily maximum | ≤ .0478 lb/d | all year | 001 |
| Flow, in conduit or thru treatment plant | daily average | ≤ .28 MGD | all year | 001 |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year | 001 |
| Solids, total dissolved | daily average | ≤ 886 mg/L | all year | 001 |
| Solids, total dissolved | daily maximum | ≤ 1875 mg/L | all year | 001 |
| pH | minimum | ≥ 6 SU | all year | 101 |
| pH | maximum | ≤ 9 SU | all year | 101 |
| Solids, total suspended | daily average | report only (lb/d) | all year | 101 |
| Solids, total suspended | daily maximum | ≤ 1.44 lb/d | all year | 101 |
| Oil & Grease | daily average | report only (lb/d) | all year | 101 |
| Oil & Grease | daily maximum | ≤ .602 lb/d | all year | 101 |
| Chromium, total [as Cr] | daily average | report only (lb/d) | all year | 101 |
| Chromium, total [as Cr] | daily maximum | ≤ .024 lb/d | all year | 101 |
| Lead, total [as Pb] | daily average | report only (lb/d) | all year | 101 |
| Lead, total [as Pb] | daily maximum | ≤ .0108 lb/d | all year | 101 |
| Nickel, total [as Ni] | daily average | report only (lb/d) | all year | 101 |
| Nickel, total [as Ni] | daily maximum | ≤ .022 lb/d | all year | 101 |
| Zinc, total [as Zn] | daily average | report only (lb/d) | all year | 101 |
| Zinc, total [as Zn] | daily maximum | ≤ .0073 lb/d | all year | 101 |
| Flow, in conduit or thru treatment plant | daily average | report only (MGD) | all year | 101 |
| Flow, in conduit or thru treatment plant | daily maximum | ≤ .004 MGD | all year | 101 |
Cited limits by parameter: Texas's rules and the federal ones.
Same industry: the 13 Primary Metal Industries permits in Texas.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/TX0034681 · MCP: https://passage-data.com/mcp