Ecoelectrica LNG & Cogeneratio

Electric Services, major discharger, Penuelas, Puerto Rico. NPDES permit PR0025984, in force until Nov 30, 2030. Last 12 months: over a limit once (last November 2025). Source: EPA ECHO, Oct 22, 2026.

Reports due
About 28 days after each period: form 1 monthly (20 values), form Q quarterly, form Y yearly
Last report on file
September 2026
Oct 2024 – Sep 2025
0 values over a limit, 0 required values missing, 0 of 13 reports late

Last 12 months (Oct 1, 2025 – Sep 30, 2026)

Period endingParameterReportedLimitOver by
November 2025Copper, total [as Cu], daily maximum4 ug/L≤ 3.73 ug/L7%

Limits in force (26)

ParameterStatisticLimitMonths
Temperature, water deg. centigradedaily maximumreport only (deg C)all year
Temp. diff. between samp. & upstrm deg. Cdaily maximum≤ 1.8 deg Call year
Turbiditydaily maximum≤ 10 NTUall year
Color [PT-CO units]daily maximumreport only (col unit (pc))all year
Oxygen, dissolved [DO]instantaneous minimum≥ 5 mg/Lall year
BOD, 5-day, 20 deg. Cmonthly average≤ 30 mg/Lall year
pHminimum≥ 7.3 SUall year
pHmaximum≤ 8.5 SUall year
Solids, total suspendedmonthly average≤ 30 mg/Lall year
Solids, total suspendeddaily maximum≤ 100 mg/Lall year
Solids, settleabledaily maximumreport only (mg/L)all year
Oil & Greasemonthly average≤ 15 mg/Lall year
Oil & Greasedaily maximum≤ 20 mg/Lall year
Arsenic, total [as As]daily maximumreport only (ug/L)all year
Chromium, total [as Cr]monthly average≤ .2 mg/Lall year
Chromium, total [as Cr]daily maximum≤ .2 mg/Lall year
Copper, total [as Cu]daily maximum≤ 3.73 ug/Lall year
Zinc, total [as Zn]daily maximum≤ 81 ug/Lall year
Flow, in conduit or thru treatment plantdaily maximum≤ 81007 m3/dall year
Flow, in conduit or thru treatment plantdaily maximum≤ 21.4 MGDall year
Chlorine, total residualdaily maximum≤ 20 ug/Lall year
Chlorine, free availablemonthly average≤ .2 mg/Lall year
Chlorine, free availabledaily maximum≤ .5 mg/Lall year
Cyanide, free availabledaily maximum≤ 1 ug/Lall year
Priority Pollutant Resultsdaily maximum≤ 0 abst=0;prst=1all year
Mercury, total [as Hg]daily maximum≤ .051 ug/Lall year

How strict are these limits?

Cited limits by parameter: we hold no rule of Puerto Rico's own; the federal ones.

Same industry: the 5 Electric Services permits in Puerto Rico.

Check this month's numbers Email me before each report is due

· Save this facility as a site · Superfund sites nearby · Your permits on one board

On EPA ECHO: Facility report · DMR history

Your permit document is the final word. As JSON: /api/v1/permits/PR0025984 · MCP: https://passage-data.com/mcp