{"permit":"PR0025984","name":"ECOELECTRICA LNG & COGENERATIO","state":"PR","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/PR0025984"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Penuelas, Puerto Rico","href":"https://www.openstreetmap.org/?mlat=17.978333&mlon=-66.756944#map=14/17.978333/-66.756944"},{"label":"Last 12 months","text":"Over a limit once, last in November 2025 (Copper, total [as Cu])"},{"label":"Permit","text":"In force until Nov 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"PR","sic":"4911","permits":5,"list":"https://passage-data.com/api/v1/permits?state=PR&sic=4911","page":"https://passage-data.com/dmr/s/PR/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":1,"over_by":[["Copper, total [as Cu]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Temp. diff. between samp. & upstrm deg. C","parameter_code":"00016","statistic":"daily maximum","qualifier":"<=","value":"1.8","unit":"deg C","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"NTU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Color [PT-CO units]","parameter_code":"00080","statistic":"daily maximum","qualifier":null,"value":null,"unit":"col unit (pc)","report_only":true,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Oxygen, dissolved [DO]","parameter_code":"00300","statistic":"instantaneous minimum","qualifier":">=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"7.3","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated cooling tower blowdown"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"3.73","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated cooling tower blowdown"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"81","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated cooling tower blowdown"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"81007","unit":"m3/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"21.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Cyanide, free available","parameter_code":"51173","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatedd cooling tower blowdown."},{"outfall":"001","parameter":"Priority Pollutant Results","parameter_code":"51577","statistic":"daily maximum","qualifier":"<=","value":"0","unit":"abst=0;prst=1","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated cooling tower blowdown"},{"outfall":"001","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":".051","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated cooling tower blowdown"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"PR","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=PR&sic=4911","url":"https://passage-data.com/api/v1/permits?state=PR&sic=4911","page":"https://passage-data.com/dmr/s/PR/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"PR0025984"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=PR0025984"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"PR0025984"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=PR0025984"}]}