Passage Data · Cited limits by place · Use it from your AI

Copper limits and guidelines in Texas (US-TX)

2,402 cited rows from 24 instruments, Texas's own first. Not covered: a permit's own limits, or rules outside the 70 instruments we hold for Texas (US-TX) and United States. Everything held for Texas

Texas: surface water 5, groundwater 5, soil 16 · United States: drinking water 5, surface water 5, effluent 2,360, soil 6

Texas (US-TX): 26 rows

Surface water: 5 rows

Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022) · 2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with… · 5 guidelines
Every row: water: the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))
ValueStatisticApplies whenCite
0.960me(0.9422(ln(hardness))-1.6448) µg/Ldaily averagereceiving water: freshwater
hardness-dependent: the cell's equation of the receiving water's hardness (mg/L as input)
30 TAC §307.6(c) Table 1 · p. 37
0.960me(0.8545(ln(hardness))-1.6463) µg/Lweekly averageas aboveas above
13.5w µg/Ldaily averagereceiving water: marineas above
3.6w µg/Lweekly averageas aboveas above
3.6w µg/Ldaily averagereceiving water: marine
designated oyster waters, outside the mixing zone of permitted discharges (30 TAC §307.6 Table 1 note 1)
30 TAC §307.6(c) Table 1 · p. 40
1 In designated oyster waters, an acute saltwater copper criterion of 3.6w micrograms per liter applies outside of the mixing zone of permitted discharges and specified mixing zones for copper do not encompass oyster reefs containing live oysters.

Groundwater: 5 rows

Texas Risk Reduction Program (30 TAC Chapter 350) · TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version) · 5 thresholds
Every row: 1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.
ValueApplies whenCite
1.3E+00 mg/Lresidential land useTRRP Table 3, Groundwater, GWGWIng, Residential · p. 41
1.3E+02 mg/Las aboveTRRP Table 3, Groundwater, GWGWClass3, Residential · p. 41
1.3E+00 mg/Lcommercial/industrial land useTRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial · p. 41
1.3E+02 mg/Las aboveTRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial · p. 41
1.0E+00 mg/LTRRP Table 3, Groundwater, Secondary MCL · p. 41

Soil: 16 rows

Texas Risk Reduction Program (30 TAC Chapter 350) · TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version) · 16 thresholds, 5 shown
Every row: 1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.
ValueApplies whenCite
1.3E+03 mg/kgresidential land use, 0.5 acre source areaTRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area · p. 12
1.0E+03 mg/kgas aboveTRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area · p. 12
1.0E+05 mg/kgas aboveTRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area · p. 12
8.0E+02 mg/kgas aboveTRRP Table 1, Residential Soil, GWSoil for Secondary MCL, 0.5 acre source area · p. 12
1.3E+03 mg/kgresidential land use, 30 acre source areaTRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area · p. 12

All 16 rows from Texas Risk Reduction Program (30 TAC Chapter 350)

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

United States (US): 2,376 rows

Drinking water: 5 rows

40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01 · 2 rows
ValueKindApplies whenCite
1.3 mg/lguideline40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals.141.51
1.3 mg/Lthreshold40 CFR 141.2: Action level, for the purpose of subpart I of this part only, means the concentrations of lead or copper in water as specified in § 141.80(c) which determines requirements under subpart I of this part.
90th percentile concentration of copper as specified in paragraph (c)(3) of this section
(3) Community water systems and non-transient non-community water systems must comply with the requirements of this subpart no later than November 1, 2027
141.80(c)(2)
(2) The copper action level is exceeded if the 90th percentile concentration of copper as specified in paragraph (c)(3) of this section is greater than 1.3 mg/L.
40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01 · 1 guideline
ValueApplies whenCite
1.0 mg/l40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States.143.3
US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water · November 2024 · 2 guidelines
Every row: Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024
ParameterValueCite
Copper800 µg/Lsource
~Copper Cyanide100 µg/Las above

Surface water: 5 rows

EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC) · EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year · 4 guidelines
Every row: EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
ValueApplies whenCite
4.8 µg/Lreceiving water: marine
Saltwater CMC (acute): criterion maximum concentration, acute
National Recommended Aquatic Life Criteria table
Copper (P) 7440508 — — 4.8 3.1 2007
3.1 µg/Lreceiving water: marine
Saltwater CCC (chronic): criterion continuous concentration, chronic
as above
Freshwater criteria calculated using the Biotic Ligand Model.receiving water: freshwater
Freshwater CMC (acute): Freshwater criteria calculated using the Biotic Ligand Model; never evaluated here
as above
Freshwater criteria calculated using the Biotic Ligand Model.receiving water: freshwater
Freshwater CCC (chronic): Freshwater criteria calculated using the Biotic Ligand Model; never evaluated here
as above
EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only) · EPA web table (fetched 2026-10-09); each criterion carries its publication year · 1 guideline
ValueApplies whenCite
1,300 µg/LEPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
receiving water: freshwater
consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)
National Recommended Water Quality Criteria — Human Health Criteria Table
Copper (P) 7440508 1,300 — 1992

Effluent: 2,360 rows

40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05 · 28 limits, 5 shown
Every row: discharge to a sewer (pretreatment); existing sources (PSES)
ParameterValueStatisticApplies whenCite
Cu4.5 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
Cu 4.5 2.7
Cu2.7 mg/L—as aboveas above
Cu176 mg/sq m-Operationdaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.14 (PSES)
Cu 176 105
Cu105 mg/sq m-Operation—as aboveas above
Cu4.5 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.24 (PSES)
Cu 4.5 2.7

All 28 rows from 40 CFR Part 413 — Electroplating point source category

40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers · eCFR as of 2026-08-01 · 8 limits
Every row: (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i; discharge to surface water
ParameterValueStatisticApplies whenCite
Total Copper3,380 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Copper 3,380 1,450
Total Copper3,380 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Copper 3,380 1,450
Total Copper1,450 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Copper 3,380 1,450
Total Copper1,450 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Copper 3,380 1,450
Total Copper3,380 µg/Ldaily maximumthe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Total Copper 3,380 1,450
Total Copper3,380 µg/Ldaily maximumthe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Total Copper 3,380 1,450
Total Copper1,450 µg/Lmonthly averagethe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Total Copper 3,380 1,450
Total Copper1,450 µg/Lmonthly averagethe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Total Copper 3,380 1,450
40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01 · 30 limits, 5 shown
Every row: the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
ParameterValueStatisticApplies whenCite
Copper (T)0.018 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
existing sources (BPT)
table: Subpart F—Chlor-Alkali Diaphragm Cells
40 CFR 415.62 (BPT)
Copper (T) 0.018 0.0070
Copper (T)0.0070 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Copper (T)0.012 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
existing sources (BAT)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.63 (BAT)
Copper (T) 0.012 0.0049
Copper (T)0.0049 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Copper (T)2.1 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.64 (PSES)
Copper (T) 2.1 0.80

All 30 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category

40 CFR Part 421 — Nonferrous metals manufacturing point source category · eCFR as of 2026-10-05 · 725 limits, 5 shown
Every row: discharge to surface water
ValueStatisticApplies whenCite
0.003 kilograms per 1,000 kg of productmonthly averagethe discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory
existing sources (BPT)
(d) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart and which processes residues by wet methods, after application of the best practical control technology currently available:
table: Effluent Limitations
40 CFR 421.32 (BPT)
Copper 0.003
0.0017 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product)daily maximumthe discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory
existing sources (BPT)
table: Effluent Limitations
40 CFR 421.52 (BPT)
Copper 0.0017 0.0008
0.0008 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product)monthly averageas aboveas above
.638 mg/kg (pounds per million pounds) of copper castdaily maximumthe discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory
existing sources (BAT)
(a) Subpart E—Casting Contact Cooling.
table: BAT Effluent Limitations
40 CFR 421.53 (BAT)
Copper .638 .304
.304 mg/kg (pounds per million pounds) of copper castmonthly averageas aboveas above

All 725 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category

40 CFR Part 423 — Steam electric power generating point source category · eCFR as of 2026-10-05 · 11 limits, 5 shown
Every row: discharge to surface water
ParameterValueStatisticApplies whenCite
Copper, total1.0 mg/Ldaily maximumexisting sources (BPT)
(5) The quantity of pollutants discharged in metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of metal cleaning wastes times the concentration listed in the following table:
40 CFR 423.12 (BPT)
Copper, total 1.0 1.0
Copper, total1.0 mg/Lmonthly averageas aboveas above
Copper, total1.0 mg/Ldaily maximumexisting sources (BAT)
(e) The quantity of pollutants discharged in chemical metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of chemical metal cleaning wastes times the concentration listed in the following table:
40 CFR 423.13 (BAT)
Copper, total 1.0 1.0
Copper, total1.0 mg/Lmonthly averageas aboveas above
Copper, total1.0 mg/Ldaily maximumnew sources (NSPS)
(4) Chemical metal cleaning wastes. The quantity of pollutants discharged in chemical metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of chemical metal cleaning wastes times the concentration listed in the following table:
40 CFR 423.15 (NSPS)
Copper, total 1.0 1.0

All 11 rows from 40 CFR Part 423 — Steam electric power generating point source category

40 CFR Part 429 — Timber products processing point source category · eCFR as of 2026-10-05 · 4 limits
Every row: discharge to a sewer (pretreatment); existing sources (PSES)
ValueStatisticApplies whenCite
5 mg/Ldaily maximumthe discharge is of the Subpart G—Wood Preserving Steam Subcategory
table: Subpart G [PSES Effluent Limitations]
40 CFR 429.85 (PSES)
Copper 5
.62daily maximumthe discharge is of the Subpart G—Wood Preserving Steam Subcategory
table: [Grams per cubic meter of production]
40 CFR 429.85 (PSES)
Copper .62
5 mg/Ldaily maximumthe discharge is of the Subpart H—Wood Preserving—Boulton Subcategory
table: Subpart H [PSES Effluent Limitations]
40 CFR 429.95 (PSES)
Copper 5
.62daily maximumthe discharge is of the Subpart H—Wood Preserving—Boulton Subcategory
table: Subpart H [PSES Effluent Limitations; grams per cu m of production]
40 CFR 429.95 (PSES)
Copper .62
40 CFR Part 433 — Metal finishing point source category · eCFR as of 2026-10-05 · 10 limits, 5 shown
Every row: the discharge is of the Subpart A—Metal Finishing Subcategory
ParameterValueStatisticApplies whenCite
Copper (T)3.38 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: BPT Effluent Limitations
40 CFR 433.13 (BPT)
Copper (T) 3.38 2.07
Copper (T)2.07 mg/Lmonthly averageas aboveas above
Copper (T)3.38 mg/Ldaily maximumdischarge to surface water
existing sources (BAT)
table: BAT Effluent Limitations
40 CFR 433.14 (BAT)
Copper (T) 3.38 2.07
Copper (T)2.07 mg/Lmonthly averageas aboveas above
Copper (T)3.38 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers
40 CFR 433.15 (PSES)
Copper (T) 3.38 2.07

All 10 rows from 40 CFR Part 433 — Metal finishing point source category

40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05 · 42 limits, 5 shown
Every row: discharge to surface water
ValueStatisticApplies whenCite
4.14 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.11 (BPT)
Copper 4.14 1.06
1.06 mg/Lmonthly averageas aboveas above
0.659 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
new sources (NSPS)
table: Performance Standards
40 CFR 437.14 (NSPS)
Copper 0.659 0.216
0.216 mg/Lmonthly averageas aboveas above
0.500 mg/Ldaily maximumthe discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.21 (BPT)
Copper 0.500 0.242

All 42 rows from 40 CFR Part 437 — The centralized waste treatment point source category

40 CFR Part 440 — Ore mining and dressing point source category · eCFR as of 2026-10-05 · 46 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart F—Tungsten Ore Subcategory; existing sources (BPT)
ParameterValueStatisticApplies whenCite
Cu.3 mg/Ldaily maximum(a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed:40 CFR 440.62 (BPT)
Cu .3 .15
Cu.15 mg/Lmonthly averageas aboveas above
Cu.30 mg/Ldaily maximum(c) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by purely physical methods including ore crushing, washing, jigging, heavy media separation, and magnetic and electrostatic separation shall not exceed:40 CFR 440.62 (BPT)
Cu .30 .15
Cu.15 mg/Lmonthly averageas aboveas above
Cu.30 mg/Ldaily maximum(d) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by froth flotation methods shall not exceed:as above

All 46 rows from 40 CFR Part 440 — Ore mining and dressing point source category

40 CFR Part 442 — Transportation equipment cleaning point source category · eCFR as of 2026-10-05 · 5 limits
ValueStatisticApplies whenCite
0.84 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos
existing sources (BPT)
(a) Effluent Limitations
40 CFR 442.11 (BPT)
Copper 0.84
0.84 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos
existing sources (PSES)
table: Table—Pretreatment Standards
40 CFR 442.15 (PSES)
Copper 0.84
0.84 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos
new sources (PSNS)
table: Table—Pretreatment Standards
40 CFR 442.16 (PSNS)
Copper 0.84
0.10 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos
existing sources (BPT)
table: Table—Effluent Limitations
40 CFR 442.31 (BPT)
Copper 0.10
0.10 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos
existing sources (PSES)
table: Table—Pretreatment Standards
40 CFR 442.35 (PSES)
Copper 0.10
40 CFR Part 444 — Waste combustors point source category · eCFR as of 2026-10-05 · 4 limits
Every row: the discharge is of the Subpart A—Commercial Hazardous Waste Combustor Subcategory
ValueStatisticApplies whenCite
23 µg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: Effluent Limitations 1
40 CFR 444.13 (BPT)
Copper 23 14
14 µg/Lmonthly averageas aboveas above
23 µg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Pretreatment Standards 1
40 CFR 444.16 (PSES)
Copper 23 14
14 µg/Lmonthly averageas aboveas above
40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05 · 94 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart C—Lead Subcategory; existing sources (BPT); table: BPT Effluent Limitations
ValueStatisticApplies whenCite
0.86 mg/kg of lead useddaily maximum(1) Subpart C—Closed Formation—Double Fill, or Fill and Dump.40 CFR 461.31 (BPT)
Copper 0.86 0.45
0.45 mg/kg of lead usedmonthly averageas aboveas above
20.99 mg/kg of lead useddaily maximum(2) Subpart C—Open Formation—Dehydrated.40 CFR 461.31 (BPT)
Copper 20.99 11.05
11.05 mg/kg of lead usedmonthly averageas aboveas above
0.10 mg/kg of lead useddaily maximum(3) Subpart C—Open Formation—Wet.40 CFR 461.31 (BPT)
Copper 0.10 0.05

All 94 rows from 40 CFR Part 461 — Battery manufacturing point source category

40 CFR Part 464 — Metal molding and casting point source category · eCFR as of 2026-10-05 · 587 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Aluminum Casting Subcategory; existing sources (BPT); (a) Casting Cleaning Operations.
ParameterValueStatisticApplies whenCite
Copper (T)0.0771 kg/1,000 kkg (pounds per million pounds) of metal poureddaily maximumtable: BPT Effluent Limitations40 CFR 464.12 (BPT)
Copper (T) 0.0771 0.0421
Copper (T)0.0421 kg/1,000 kkg (pounds per million pounds) of metal pouredmonthly averageas aboveas above
Copper (T)0.77 mg/Ldaily maximum40 CFR 464.12 (BPT)
Copper (T) 0.77 0.42 0.017
Copper (T)0.42 mg/Lmonthly averageas above
Copper (T)0.017 kg/1,000 kkg (pounds per million pounds) of metal pouredannual averageas above

All 587 rows from 40 CFR Part 464 — Metal molding and casting point source category

40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05 · 10 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart B—Galvanized Basis Material Subcategory; table: Subpart B
ValueStatisticApplies whenCite
4.96 mg/m (pounds per 1 million ft ) of area processeddaily maximumexisting sources (BPT)40 CFR 465.21 (BPT)
Copper 4.96 (1.02) 2.61 (0.54)
2.61 mg/m (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
1.71 mg/m (pounds per 1 million ft ) of area processeddaily maximumexisting sources (BAT)40 CFR 465.22 (BAT)
Copper 1.71 (0.35) 0.90 (0.19)
0.90 mg/m (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
0.44 mg/m (pounds per 1 million ft ) of area processeddaily maximumnew sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 465.23 (NSPS)
Copper 0.44 (0.090) 0.21 (0.043)

All 10 rows from 40 CFR Part 465 — Coil coating point source category

40 CFR Part 468 — Copper forming point source category · eCFR as of 2026-10-05 · 170 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Copper Forming Subcategory; existing sources (BPT)
ValueStatisticApplies whenCite
0.195 mg/off-kg of copper or copper alloy hot rolleddaily maximum(a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Copper 0.195 0.103
0.103 mg/off-kg of copper or copper alloy hot rolledmonthly averageas aboveas above
0.720 mg/off-kg of copper or copper alloy cold rolleddaily maximum(b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Copper 0.720 0.379
0.379 mg/off-kg of copper or copper alloy cold rolledmonthly averageas aboveas above
0.161 mg/off-kg of copper or copper alloy drawndaily maximum(c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Copper 0.161 0.085

All 170 rows from 40 CFR Part 468 — Copper forming point source category

40 CFR Part 471 — Nonferrous metals forming and metal powders point source category · eCFR as of 2026-10-05 · 586 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart D—Precious Metals Forming Subcategory; existing sources (BPT); table: Subpart D—BPT
ValueStatisticApplies whenCite
0.147 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsionsdaily maximum(b) Rolling spent emulsions.40 CFR 471.41 (BPT)
Copper 0.147 0.077
0.077 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsionsmonthly averageas aboveas above
0.091 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsionsdaily maximum(d) Drawing spent emulsions.40 CFR 471.41 (BPT)
Copper 0.091 0.048
0.048 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsionsmonthly averageas aboveas above
0.006 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutionsdaily maximum(e) Drawing spent soap solutions.40 CFR 471.41 (BPT)
Copper 0.006 0.003

All 586 rows from 40 CFR Part 471 — Nonferrous metals forming and metal powders point source category

Soil: 6 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil · November 2024 · 6 rows
ParameterValueKindApplies whenCite
Copper3100 mg/kgguidelineResident Soil (mg/kg)source
Copper47000 mg/kgguidelineIndustrial Soil (mg/kg)as above
Copper28 mg/kgguidelineProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Copper46 mg/kgreference value (not a limit)Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1as above
~Copper Cyanide390 mg/kgguidelineResident Soil (mg/kg)as above
~Copper Cyanide5800 mg/kgguidelineIndustrial Soil (mg/kg)as above

This page shows 112 of 2,402 rows: every instrument, each with its first 5 rows or all of them. All 2,402 as JSON, 200 a page.

33 NPDES permits in Texas went over a copper limit in their last 12 months of reports: the list as JSON.

What was searched

70 instruments we hold for Texas (US-TX) and United States, for 19 names matching “copper” (each in the JSON). 24 have a row, in the tables above; 46 have none.

46 instruments with no row for copper
  1. 40 CFR 52.21 — Prevention of significant deterioration of air quality · eCFR 2026-08-01
  2. 40 CFR 63.2 — Definitions (major source of hazardous air pollutants) · eCFR 2026-08-01
  3. 40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity… · eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)
  4. 40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,…
  5. 40 CFR Part 50, National Primary and Secondary Ambient Air Quality Standards, §§ 50.4–50.21 (eCFR as of 2026-08-01) · 90 FR 4651, Jan. 16, 2025
  6. 40 CFR Part 133 — Secondary Treatment Regulation · eCFR as of 2026-10-05
  7. 40 CFR Part 405 — Dairy products processing point source category · eCFR as of 2026-10-05
  8. 40 CFR Part 406 — Grain mills point source category · eCFR as of 2026-10-05
  9. 40 CFR Part 407 — Canned and preserved fruits and vegetables processing point source category · eCFR as of 2026-10-05
  10. 40 CFR Part 408 — Canned and preserved seafood processing point source category · eCFR as of 2026-10-05
  11. 40 CFR Part 409 — Sugar processing point source category · eCFR as of 2026-10-05
  12. 40 CFR Part 410 — Textile mills point source category · eCFR as of 2026-10-05
  13. 40 CFR Part 411 — Cement manufacturing point source category · eCFR as of 2026-10-05
  14. 40 CFR Part 412 — Concentrated animal feeding operations (CAFO) point source category · eCFR as of 2026-10-05
  15. 40 CFR Part 417 — Soap and detergent manufacturing point source category · eCFR as of 2026-10-05
  16. 40 CFR Part 418 — Fertilizer manufacturing point source category · eCFR as of 2026-08-01
  17. 40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05
  18. 40 CFR Part 420 — Iron and steel manufacturing point source category · eCFR as of 2026-10-05
  19. 40 CFR Part 422 — Phosphate manufacturing point source category · eCFR as of 2026-08-01
  20. 40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05
  21. 40 CFR Part 425 — Leather tanning and finishing point source category · eCFR as of 2026-10-05
  22. 40 CFR Part 426 — Glass manufacturing point source category · eCFR as of 2026-10-05
  23. 40 CFR Part 427 — Asbestos manufacturing point source category · eCFR as of 2026-10-05
  24. 40 CFR Part 428 — Rubber manufacturing point source category · eCFR as of 2026-10-05
  25. 40 CFR Part 430 — The pulp, paper, and paperboard point source category · eCFR as of 2026-10-05
  26. 40 CFR Part 432 — Meat and poultry products point source category · eCFR as of 2026-10-05
  27. 40 CFR Part 434 — Coal mining point source category BPT, BAT, BCT limitations and new source performance standards · eCFR as of 2026-10-05
  28. 40 CFR Part 435 — Oil and gas extraction point source category · eCFR as of 2026-10-05
  29. 40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05
  30. 40 CFR Part 438 — Metal products and machinery point source category · eCFR as of 2026-10-05
  31. 40 CFR Part 439 — Pharmaceutical manufacturing point source category · eCFR as of 2026-10-05
  32. 40 CFR Part 443 — Effluent limitations guidelines for existing sources and standards of performance and pretreatment… · eCFR as of 2026-10-05
  33. 40 CFR Part 445 — Landfills point source category · eCFR as of 2026-10-05
  34. 40 CFR Part 446 — Paint formulating point source category · eCFR as of 2026-10-05
  35. 40 CFR Part 447 — Ink formulating point source category · eCFR as of 2026-10-05
  36. 40 CFR Part 449 — Airport deicing point source category · eCFR as of 2026-10-05
  37. 40 CFR Part 454 — Gum and wood chemicals manufacturing point source category · eCFR as of 2026-10-05
  38. 40 CFR Part 455 — Pesticide chemicals · eCFR as of 2026-10-05
  39. 40 CFR Part 457 — Explosives manufacturing point source category · eCFR as of 2026-10-05
  40. 40 CFR Part 458 — Carbon black manufacturing point source category · eCFR as of 2026-08-01
  41. 40 CFR Part 459 — Photographic point source category · eCFR as of 2026-10-05
  42. 40 CFR Part 460 — Hospital point source category · eCFR as of 2026-10-05
  43. 40 CFR Part 463 — Plastics molding and forming point source category · eCFR as of 2026-10-05
  44. 40 CFR Part 466 — Porcelain enameling point source category · eCFR as of 2026-10-05
  45. 40 CFR Part 467 — Aluminum forming point source category · eCFR as of 2026-10-05
  46. 40 CFR Part 469 — Electrical and electronic components point source category · eCFR as of 2026-10-05
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the copper limits in Texas? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=copper&place=US-TX; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.