| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| Plomb | 0,25 | µg/m³ | ambient air · guideline | Code de l'environnement, partie réglementaire, Livre II Titre II (Air et atmosphère), article R. 22… Article R. 221-1 du code de l’environnement 3. Plomb : a) Objectif de qualité : 0,25 µg/m³ en concentration moyenne annuelle civile | ||
| Plomb | 0,5 | µg/m³ | ambient air · limit | Code de l'environnement, partie réglementaire, Livre II Titre II (Air et atmosphère), article R. 22… Article R. 221-1 du code de l’environnement b) Valeur limite : 0,5 µg/m³ en moyenne annuelle civile | ||
| Plomb et ses composés (en Pb) | 0,1 mg/l | mg/l | effluent · limit | route: direct installations classées soumises à autorisation (ICPE) si le rejet dépasse 5 g/j | Arrêté du 2 février 1998, article 32 — valeurs limites de concentration des rejets au milieu naturel art. 32, 3° |
| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| Lead | 0,5 | µg/m³ | ambient air · limit | Directive 2008/50/EC on ambient air quality and cleaner air for Europe, Annexes VII, XI, XII, XIII … ANNEX XI LIMIT VALUES FOR THE PROTECTION OF HUMAN HEALTH Lead Calendar year 0,5 μg/m 3 ( 3 ) | ||
| Lead | 5 μg/l | μg/l | drinking water · limit | Directive (EU) 2020/2184 of the European Parliament and of the Council of 16 December 2020 on the q… |
Every instrument we hold for France (FR) and the place above it, European Union (EU): 10 instruments, for every parameter name matching “lead”: lead, lead total, lead acetate, triethyl lead, lead phosphate, lead ii acetate, lead subacetate, tetraethyl lead, tetramethyl lead, lead ii phosphate, total lead marine, total lead freshwater, and 5 more (in the JSON).
39c4a65fee1dfe9eecfdc1ba3f67d9dcbce681c4698a3b3dda2e9e9bb4fb0177 — 1 row here898303d53c64d79cf240e8612ecb369c3ed21a05bab2ef3da3adacbbd2b33751 — no row here8b4b75b107b98ad0f4dae8e0cd7143c2c76250665e49bbbd335b0321fdf5257e — no row here2c5b4219c78ca8f253d0846b7e843bbc6946f79d418ed6a4fbaa409fa7df6fcc — no row here1a752d504bcfdbf68ca521d73ab48fa511de01b750923089f1591f95dfa06699 — no row here0b2b3f907f291ea946596a35c6b93b20ad38834ffbec6a1cc463fef3706078f7 — no row here30803597c6139c5d630bc45b79be2f99d377ec4cbc60878ee62991252944fb3a — no row hereRead from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.