Passage Data · Check a report · Use it from your AI
Electric Services, Summerville, West Virginia. NPDES permit WV0114847, in force until Oct 18, 2027. Last 12 months: over a limit 3 times (last June 2026), 12 required values missing, 9 of 37 reports late. Source: EPA ECHO, Oct 22, 2026.
| Period ending | Parameter | Reported | Limit | Over by |
|---|---|---|---|---|
| May 2026 | Zinc, total recoverable, monthly average | .104 mg/L | ≤ .044 mg/L | 136% |
| June 2026 | Copper, total recoverable, daily maximum | .031 mg/L | ≤ .014 mg/L | 121% |
| June 2026 | Copper, total recoverable, monthly average | .031 mg/L | ≤ .007 mg/L | 343% |
| Parameter | Statistic | Limit | Months | Outfall |
|---|---|---|---|---|
| Temperature, water deg. fahrenheit | monthly average | report only (deg F) | all year | 001 |
| Temperature, water deg. fahrenheit | daily maximum | report only (deg F) | all year | 001 |
| Temperature, water deg. fahrenheit | monthly average | report only (deg F) | all year | 001 |
| Temperature, water deg. fahrenheit | daily maximum | report only (deg F) | all year | 001 |
| Temp. diff. between samp. & upstrm deg. F | monthly average | report only (deg F) | all year | 001 |
| Temp. diff. between samp. & upstrm deg. F | daily maximum | report only (deg F) | all year | 001 |
| Flow, in conduit or thru treatment plant | monthly average | report only (MGD) | all year | 001 |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year | 001 |
| Temperature, water deg. fahrenheit | monthly average | report only (deg F) | all year | 002 |
| Temperature, water deg. fahrenheit | daily maximum | report only (deg F) | all year | 002 |
| Temperature, water deg. fahrenheit | monthly average | report only (deg F) | all year | 002 |
| Temperature, water deg. fahrenheit | daily maximum | report only (deg F) | all year | 002 |
| Temp. diff. between samp. & upstrm deg. F | monthly average | report only (deg F) | all year | 002 |
| Temp. diff. between samp. & upstrm deg. F | daily maximum | report only (deg F) | all year | 002 |
| Flow, in conduit or thru treatment plant | monthly average | report only (MGD) | all year | 002 |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year | 002 |
| pH | instantaneous minimum | ≥ 6 SU | all year | 003 |
| pH | instantaneous maximum | ≤ 9 SU | all year | 003 |
| Solids, total suspended | monthly average | ≤ 10 mg/L | all year | 003 |
| Solids, total suspended | monthly average | ≤ 10 mg/L | all year | 003 |
| Solids, total suspended | daily maximum | ≤ 22 mg/L | all year | 003 |
| Solids, total suspended | daily maximum | ≤ 22 mg/L | all year | 003 |
| Oil and grease, hexane extr method | monthly average | ≤ 3 mg/L | all year | 003 |
| Oil and grease, hexane extr method | monthly average | ≤ 3 mg/L | all year | 003 |
| Oil and grease, hexane extr method | daily maximum | ≤ 6 mg/L | all year | 003 |
| Oil and grease, hexane extr method | daily maximum | ≤ 6 mg/L | all year | 003 |
| Zinc, total recoverable | monthly average | ≤ .044 mg/L | all year | 003 |
| Zinc, total recoverable | daily maximum | ≤ .12 mg/L | all year | 003 |
| Lead, total recoverable | monthly average | report only (mg/L) | all year | 003 |
| Lead, total recoverable | daily maximum | report only (mg/L) | all year | 003 |
| Copper, total recoverable | monthly average | ≤ .007 mg/L | all year | 003 |
| Copper, total recoverable | daily maximum | ≤ .014 mg/L | all year | 003 |
| Flow, in conduit or thru treatment plant | monthly average | report only (MGD) | all year | 003 |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year | 003 |
Cited limits by parameter: West Virginia's rules and the federal ones.
Same industry: the 24 Electric Services permits in West Virginia.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/WV0114847 · MCP: https://passage-data.com/mcp