Sewerage Systems, Johnson County, Texas. NPDES permit TX0113573, in force until Oct 12, 2027. Last 12 months: over a limit 11 times (last August 2026). Source: EPA ECHO, Oct 22, 2026.
| Period ending | Parameter | Reported | Limit | Over by |
|---|---|---|---|---|
| November 2025 | Solids, total suspended, daily average | 17 mg/L | ≤ 15 mg/L | 13% |
| February 2026 | Solids, total suspended, daily average | 29.25 mg/L | ≤ 15 mg/L | 95% |
| March 2026 | Solids, total suspended, daily average | 41.4 mg/L | ≤ 15 mg/L | 176% |
| March 2026 | Solids, total suspended, single grab sample | 67 mg/L | ≤ 60 mg/L | 12% |
| April 2026 | Solids, total suspended, daily average | 23.5 mg/L | ≤ 15 mg/L | 57% |
| May 2026 | Solids, total suspended, daily average | 25 mg/L | ≤ 15 mg/L | 67% |
| June 2026 | Solids, total suspended, daily average | 19.6 mg/L | ≤ 15 mg/L | 31% |
| July 2026 | Solids, total suspended, daily average | 51.5 mg/L | ≤ 15 mg/L | 243% |
| July 2026 | Solids, total suspended, single grab sample | 67 mg/L | ≤ 60 mg/L | 12% |
| August 2026 | Solids, total suspended, daily average | 46.75 mg/L | ≤ 15 mg/L | 212% |
| August 2026 | Solids, total suspended, single grab sample | 82 mg/L | ≤ 60 mg/L | 37% |
| Parameter | Statistic | Limit | Months |
|---|---|---|---|
| Oxygen, dissolved [DO] | monthly minimum | ≥ 4 mg/L | all year |
| BOD, 5-day, 20 deg. C | daily average | ≤ 10 mg/L | all year |
| BOD, 5-day, 20 deg. C | single grab sample | ≤ 35 mg/L | all year |
| BOD, 5-day, 20 deg. C | daily average | ≤ 3.5 lb/d | all year |
| pH | minimum | ≥ 6 SU | all year |
| pH | maximum | ≤ 9 SU | all year |
| Solids, total suspended | daily average | ≤ 15 mg/L | all year |
| Solids, total suspended | single grab sample | ≤ 60 mg/L | all year |
| Solids, total suspended | daily average | ≤ 5.2 lb/d | all year |
| Flow, in conduit or thru treatment plant | daily average | ≤ .042 MGD | all year |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year |
| Chlorine, total residual | monthly minimum | ≥ 1 mg/L | all year |
| Chlorine, total residual | monthly maximum | ≤ 4 mg/L | all year |
| E. coli | daily average | ≤ 126 CFU/100mL | all year |
| E. coli | single grab sample | ≤ 399 CFU/100mL | all year |
Cited limits by parameter: Texas's rules and the federal ones.