Passage Data · Check a report · Use it from your AI

Coleto Creek Power, LLC

Electric Services, major discharger, Fannin, Texas. NPDES permit TX0070068, in force until Nov 20, 2028. Last 12 months: no values over a limit, 2 required values missing, 2 of 37 reports late. Source: EPA ECHO, Oct 22, 2026.

Reports due
About 20 days after each period: outfall 001 form A monthly (17 values), outfall 201 form A monthly (12 values), outfall 301 form A monthly (8 values), outfall TX1 form S twice a year, outfall TX1 form Y yearly, outfall TXA form S twice a year
Last report on file
August 2026
Oct 2024 – Sep 2025
1 value over a limit, 0 required values missing, 0 of 41 reports late

Limits in force (69)

ParameterStatisticLimitMonthsOutfall
Temperature, water deg. fahrenheitdaily average≤ 108 deg Fall year001
Temperature, water deg. fahrenheitdaily maximum≤ 110 deg Fall year001
Temperature, water deg. fahrenheitdaily average≤ 106 deg Fall year001
Temperature, water deg. fahrenheitdaily maximum≤ 110 deg Fall year001
Copper, total [as Cu]daily maximumreport only (mg/L)all year001
Copper, total [as Cu]daily maximumreport only (lb/d)all year001
Flow, in conduit or thru treatment plantdaily average≤ 557 MGDall year001
Flow, in conduit or thru treatment plantdaily maximum≤ 560 MGDall year001
Chlorine, total residualdaily maximum≤ .2 mg/Lall year001
Chlorine, total residualdaily maximum≤ 77.4 lb/dall year001
Chlorine, free availabledaily average≤ .2 mg/Lall year001
Chlorine, free availabledaily maximum≤ .5 mg/Lall year001
Chlorine, free availabledaily average≤ 77.4 lb/dall year001
Chlorine, free availabledaily maximum≤ 193 lb/dall year001
Depth of pond or reservoir in feetmonthly minimumreport only (ft)all year001
Depth of pond or reservoir in feetmonthly averagereport only (ft)all year001
Depth of pond or reservoir in feetmonthly maximumreport only (ft)all year001
pHminimum≥ 6 SUall year201
pHmaximum≤ 9 SUall year201
Solids, total suspendeddaily average≤ 30 mg/Lall year201
Solids, total suspendeddaily maximum≤ 100 mg/Lall year201
Oil & Greasedaily average≤ 15 mg/Lall year201
Oil & Greasedaily maximum≤ 20 mg/Lall year201
Copper, total [as Cu]daily average≤ .5 mg/Lall year201
Copper, total [as Cu]daily maximum≤ 1 mg/Lall year201
Iron, total [as Fe]daily average≤ 1 mg/Lall year201
Iron, total [as Fe]daily maximum≤ 1 mg/Lall year201
Flow, in conduit or thru treatment plantdaily averagereport only (MGD)all year201
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year201
BOD, 5-day, 20 deg. Cdaily maximum≤ 45 mg/Lall year301
pHminimum≥ 6 SUall year301
pHmaximum≤ 9 SUall year301
Solids, total suspendeddaily maximum≤ 50 mg/Lall year301
Flow, in conduit or thru treatment plantdaily averagereport only (MGD)all year301
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year301
E. colidaily average≤ 126 CFU/100mLall year301
E. colidaily maximum≤ 399 CFU/100mLall year301
Whole effluent toxicity - retest #17-day minimumreport only (pass=0;fail=1)all yearTX1
Whole effluent toxicity - retest #1monthly average minimumreport only (pass=0;fail=1)all yearTX1
Whole effluent toxicity - retest #27-day minimumreport only (pass=0;fail=1)all yearTX1
Whole effluent toxicity - retest #2monthly average minimumreport only (pass=0;fail=1)all yearTX1
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (pass=0;fail=1)all yearTX1
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (pass=0;fail=1)all yearTX1
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas7-day minimumreport only (pass=0;fail=1)all yearTX1
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelasmonthly average minimumreport only (pass=0;fail=1)all yearTX1
NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (%)all yearTX1
NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (%)all yearTX1
NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas7-day minimumreport only (%)all yearTX1
NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelasmonthly average minimumreport only (%)all yearTX1
NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (%)all yearTX1
NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (%)all yearTX1
NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas7-day minimumreport only (%)all yearTX1
NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelasmonthly average minimumreport only (%)all yearTX1
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (pass=0;fail=1)all yearTX1
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (pass=0;fail=1)all yearTX1
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas7-day minimumreport only (pass=0;fail=1)all yearTX1
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelasmonthly average minimumreport only (pass=0;fail=1)all yearTX1
LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (%)all yearTX1
LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (%)all yearTX1
LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas7-day minimumreport only (%)all yearTX1
LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelasmonthly average minimumreport only (%)all yearTX1
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia7-day minimumreport only (%)all yearTX1
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubiamonthly average minimumreport only (%)all yearTX1
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas7-day minimumreport only (%)all yearTX1
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelasmonthly average minimumreport only (%)all yearTX1
Whole effluent toxicity - retest #1single samplereport only (pass=0;fail=1)all yearTXA
Whole effluent toxicity - retest #2single samplereport only (pass=0;fail=1)all yearTXA
LC50 Pass/Fail Static 24Hr Acute D. Pulexsingle samplereport only (pass=0;fail=1)all yearTXA
LC50 Pass/Fail Static 24Hr Acute Pimephales promelassingle samplereport only (pass=0;fail=1)all yearTXA

New limits from Nov 1, 2026

ParameterNew limitNew or tighterMedian, last 12 months× new limit
Copper, total [as Cu], daily average0.5 mg/Lnew——
Copper, total [as Cu], daily maximum1 mg/Lnew——
Iron, total [as Fe], daily average1 mg/Lnew——
Iron, total [as Fe], daily maximum1 mg/Lnew——
Oil & Grease, daily average15 mg/Lnew——
Oil & Grease, daily maximum20 mg/Lnew——
Solids, total suspended, daily average30 mg/Lnew——
Solids, total suspended, daily maximum100 mg/Lnew——
pH, maximum9 SUnew——

How strict are these limits?

Cited limits by parameter: Texas's rules and the federal ones.

Same industry: the 87 Electric Services permits in Texas.

Check this month's numbers Email me before each report is due

· Save this facility as a site · Superfund sites nearby · Your permits on one board

On EPA ECHO: Facility report · DMR history

Your permit document is the final word. As JSON: /api/v1/permits/TX0070068 · MCP: https://passage-data.com/mcp