Passage Data · Check a report · Use it from your AI

Falcon Development LLC

Electric Services, Fairfield, Texas. NPDES permit TX0030180 expired May 7, 2026; its limits still apply. Last 12 months: no values over a limit, 10 of 34 reports late. Source: EPA ECHO, Oct 22, 2026.

Reports due
About 25 days after each period: outfall 001 form A monthly (2 values), outfall 002 form A monthly (10 values), outfall 101 form A monthly (14 values), outfall 002 form Y yearly
Last report on file
August 2026
Oct 2024 – Sep 2025
0 values over a limit, 0 required values missing, 0 of 37 reports late

Limits in force (27)

ParameterStatisticLimitMonthsOutfall
Flow, in conduit or thru treatment plantdaily averagereport only (MGD)all year001
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year001
pHminimum≥ 6 SUall year002
pHmaximum≤ 9 SUall year002
Solids, total suspendeddaily average≤ 30 mg/Lall year002
Solids, total suspendeddaily maximum≤ 50 mg/Lall year002
Oil & Greasedaily average≤ 15 mg/Lall year002
Oil & Greasedaily maximum≤ 20 mg/Lall year002
Iron, total [as Fe]daily average≤ 3.5 mg/Lall year002
Iron, total [as Fe]daily maximum≤ 7 mg/Lall year002
Selenium, total [as Se]daily maximum≤ .033 mg/Lall year002
Flow, in conduit or thru treatment plantdaily averagereport only (MGD)all year002
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year002
pHminimum≥ 6 SUall year101
pHmaximum≤ 9 SUall year101
Solids, total suspendeddaily average≤ 30 mg/Lall year101
Solids, total suspendeddaily maximum≤ 100 mg/Lall year101
Oil & Greasedaily average≤ 15 mg/Lall year101
Oil & Greasedaily maximum≤ 20 mg/Lall year101
Copper, total [as Cu]daily average≤ .5 mg/Lall year101
Copper, total [as Cu]daily maximum≤ 1 mg/Lall year101
Iron, total [as Fe]daily average≤ 1 mg/Lall year101
Iron, total [as Fe]daily maximum≤ 1 mg/Lall year101
Selenium, total [as Se]daily average≤ .05 mg/Lall year101
Selenium, total [as Se]daily maximum≤ .1 mg/Lall year101
Flow, in conduit or thru treatment plantdaily averagereport only (MGD)all year101
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year101

How strict are these limits?

Cited limits by parameter: Texas's rules and the federal ones.

Same industry: the 87 Electric Services permits in Texas.

Check this month's numbers Email me before each report is due

· Save this facility as a site · Superfund sites nearby · Your permits on one board

On EPA ECHO: Facility report · DMR history

Your permit document is the final word. As JSON: /api/v1/permits/TX0030180 · MCP: https://passage-data.com/mcp