Rogers, City of

Sewage treatment plant, Rogers, Texas. NPDES permit TX0027103, in force until May 15, 2029. Last 12 months: over a limit 17 times (last August 2026), 2 of 11 reports late. Source: EPA ECHO, Oct 22, 2026.

Reports due
About 20 days after each period: form A monthly (14 values)
Last report on file
August 2026
Oct 2024 – Sep 2025
10 values over a limit, 0 required values missing, 1 of 12 reports late

Last 12 months (Oct 1, 2025 – Sep 30, 2026)

All 17 values over a limit
Period endingParameterReportedLimitOver by
October 2025BOD, 5-day, 20 deg. C, daily average31 mg/L≤ 30 mg/L3%
November 2025BOD, 5-day, 20 deg. C, daily average35 mg/L≤ 30 mg/L17%
November 2025E. coli, single grab sample2420 CFU/100mL≤ 399 CFU/100mL507%
December 2025BOD, 5-day, 20 deg. C, daily average31 mg/L≤ 30 mg/L3%
January 2026BOD, 5-day, 20 deg. C, daily average40 mg/L≤ 30 mg/L33%
January 2026E. coli, single grab sample1730 CFU/100mL≤ 399 CFU/100mL334%
February 2026BOD, 5-day, 20 deg. C, daily average37 mg/L≤ 30 mg/L23%
February 2026pH, maximum9.2 SU≤ 9 SU—
March 2026BOD, 5-day, 20 deg. C, daily average36 mg/L≤ 30 mg/L20%
April 2026Oxygen, dissolved [DO], monthly minimum3.1 mg/L≥ 4 mg/L23%
May 2026BOD, 5-day, 20 deg. C, daily average38 mg/L≤ 30 mg/L27%
May 2026E. coli, single grab sample2420 CFU/100mL≤ 399 CFU/100mL507%
May 2026pH, maximum9.1 SU≤ 9 SU—
June 2026BOD, 5-day, 20 deg. C, daily average32 mg/L≤ 30 mg/L7%
June 2026E. coli, daily average165 CFU/100mL≤ 126 CFU/100mL31%
June 2026E. coli, single grab sample2420 CFU/100mL≤ 399 CFU/100mL507%
August 2026pH, maximum9.4 SU≤ 9 SU—

Limits in force (14)

ParameterStatisticLimitMonths
Oxygen, dissolved [DO]monthly minimum≥ 4 mg/Lall year
BOD, 5-day, 20 deg. Cdaily average≤ 30 mg/Lall year
BOD, 5-day, 20 deg. Csingle grab sample≤ 100 mg/Lall year
BOD, 5-day, 20 deg. Cdaily average≤ 40 lb/dall year
pHminimum≥ 6 SUall year
pHmaximum≤ 9 SUall year
Solids, total suspendeddaily average≤ 90 mg/Lall year
Solids, total suspendeddaily average≤ 121 lb/dall year
Flow, in conduit or thru treatment plantdaily average≤ .161 MGDall year
Flow, in conduit or thru treatment plantdaily maximumreport only (MGD)all year
Chlorine, total residualmonthly minimum≥ 1 mg/Lall year
Chlorine, total residualmonthly maximum≤ 4 mg/Lall year
E. colidaily average≤ 126 CFU/100mLall year
E. colisingle grab sample≤ 399 CFU/100mLall year

How strict are these limits?

Cited limits by parameter: Texas's rules and the federal ones.