Passage Data · Check a report · Use it from your AI
Electric Services, major discharger, Longview, Texas. NPDES permit TX0000540, in force until Jul 7, 2030. Last 12 months: no values over a limit. Source: EPA ECHO, Oct 22, 2026.
| Parameter | Statistic | Limit | Months | Outfall |
|---|---|---|---|---|
| Temperature, water deg. fahrenheit | daily average | ≤ 100 deg F | all year | 001 |
| Temperature, water deg. fahrenheit | daily maximum | ≤ 107 deg F | all year | 001 |
| Flow, in conduit or thru treatment plant | daily average | ≤ 740 MGD | all year | 001 |
| Flow, in conduit or thru treatment plant | daily maximum | ≤ 740 MGD | all year | 001 |
| Chlorine, total residual | daily maximum | ≤ .2 mg/L | all year | 001 |
| Chlorine, total residual | daily maximum | ≤ 63.7 lb/d | all year | 001 |
| pH | minimum | ≥ 6 SU | all year | 101 |
| pH | maximum | ≤ 9 SU | all year | 101 |
| Solids, total suspended | daily average | ≤ 30 mg/L | all year | 101 |
| Solids, total suspended | daily maximum | ≤ 100 mg/L | all year | 101 |
| Oil & Grease | daily average | ≤ 15 mg/L | all year | 101 |
| Oil & Grease | daily maximum | ≤ 20 mg/L | all year | 101 |
| Flow, in conduit or thru treatment plant | daily average | report only (MGD) | all year | 101 |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year | 101 |
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (pass=0;fail=1) | all year | TX1 |
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (pass=0;fail=1) | all year | TX1 |
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (%) | all year | TX1 |
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (%) | all year | TX1 |
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (%) | all year | TX1 |
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (%) | all year | TX1 |
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (pass=0;fail=1) | all year | TX1 |
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (pass=0;fail=1) | all year | TX1 |
| LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (%) | all year | TX1 |
| LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (%) | all year | TX1 |
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia | 7-day minimum | report only (%) | all year | TX1 |
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia | monthly average minimum | report only (%) | all year | TX1 |
| Whole effluent toxicity - retest #1 | single sample | report only (pass=0;fail=1) | all year | TXA |
| Whole effluent toxicity - retest #2 | single sample | report only (pass=0;fail=1) | all year | TXA |
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | single sample | report only (pass=0;fail=1) | all year | TXA |
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | single sample | report only (pass=0;fail=1) | all year | TXA |
Cited limits by parameter: Texas's rules and the federal ones.
Same industry: the 87 Electric Services permits in Texas.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/TX0000540 · MCP: https://passage-data.com/mcp