Passage Data · Check a report · Use it from your AI
Sewerage Systems, Sumter, South Carolina. NPDES permit SC0030724 expired Jul 31, 2021; its limits still apply. Last 12 months: no values over a limit. Source: EPA ECHO, Oct 22, 2026.
| Parameter | Statistic | Limit | Months |
|---|---|---|---|
| Oxygen, dissolved [DO] | minimum | ≥ 6 mg/L | all year |
| BOD, 5-day, 20 deg. C | monthly average | ≤ 10 mg/L | all year |
| BOD, 5-day, 20 deg. C | daily maximum | ≤ 20 mg/L | all year |
| BOD, 5-day, 20 deg. C | monthly average | ≤ 9 lb/d | all year |
| BOD, 5-day, 20 deg. C | daily maximum | ≤ 18 lb/d | all year |
| pH | minimum | ≥ 6 SU | all year |
| pH | maximum | ≤ 8.5 SU | all year |
| Solids, total suspended | monthly average | ≤ 90 mg/L | all year |
| Solids, total suspended | daily maximum | ≤ 180 mg/L | all year |
| Solids, total suspended | monthly average | ≤ 78 lb/d | all year |
| Solids, total suspended | daily maximum | ≤ 156 lb/d | all year |
| Nitrogen, ammonia total [as N] | monthly average | ≤ 2 mg/L | Jan, Feb, Nov, Dec |
| Nitrogen, ammonia total [as N] | monthly average | ≤ 1 mg/L | Mar–Oct |
| Nitrogen, ammonia total [as N] | daily maximum | ≤ 4 mg/L | Jan, Feb, Nov, Dec |
| Nitrogen, ammonia total [as N] | daily maximum | ≤ 2 mg/L | Mar–Oct |
| Nitrogen, ammonia total [as N] | monthly average | ≤ 2 lb/d | Jan, Feb, Nov, Dec |
| Nitrogen, ammonia total [as N] | monthly average | ≤ 1 lb/d | Mar–Oct |
| Nitrogen, ammonia total [as N] | daily maximum | ≤ 4 lb/d | Jan, Feb, Nov, Dec |
| Nitrogen, ammonia total [as N] | daily maximum | ≤ 2 lb/d | Mar–Oct |
| Flow, in conduit or thru treatment plant | monthly average | report only (MGD) | all year |
| Flow, in conduit or thru treatment plant | daily maximum | report only (MGD) | all year |
| Chlorine, total residual | monthly average | ≤ .1 mg/L | all year |
| Chlorine, total residual | daily maximum | ≤ .13 mg/L | all year |
| Chlorine, total residual | monthly average | ≤ .09 lb/d | all year |
| Chlorine, total residual | daily maximum | ≤ .11 lb/d | all year |
| E. coli | 30-day geometric mean | ≤ 126 MPN/100mL | all year |
| E. coli | daily maximum | ≤ 349 MPN/100mL | all year |
| E. coli | 30-day geometric mean | ≤ 126 MPN/100mL | all year |
| E. coli | daily maximum | ≤ 800 MPN/100mL | all year |
Cited limits by parameter: South Carolina's rules and the federal ones.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/SC0030724 · MCP: https://passage-data.com/mcp