Jonesville Town of

Sewage treatment plant, Jonesville, South Carolina. NPDES permit SC0024988, in force until Nov 30, 2027. Last 12 months: no values over a limit. Source: EPA ECHO, Oct 22, 2026.

Reports due
About 29 days after each period: form 1 monthly (27 values)
Renewal application due
Jun 3, 2027 · 180 days before expiry; your permit may set another date
Last report on file
August 2026
Oct 2024 – Sep 2025
0 values over a limit, 0 required values missing, 0 of 12 reports late

Limits in force (31)

ParameterStatisticLimitMonths
Oxygen, dissolved [DO]minimum≥ 5 mg/Lall year
BOD, 5-day, 20 deg. Cmonthly average≤ 30 mg/Lall year
BOD, 5-day, 20 deg. Cweekly average≤ 45 mg/Lall year
BOD, 5-day, 20 deg. Cmonthly average≤ 63 lb/dall year
BOD, 5-day, 20 deg. Cweekly average≤ 95 lb/dall year
pHminimum≥ 6 SUall year
pHmaximum≤ 8.5 SUall year
Solids, total suspendedmonthly average≤ 90 mg/Lall year
Solids, total suspendedweekly average≤ 135 mg/Lall year
Solids, total suspendedmonthly average≤ 188 lb/dall year
Solids, total suspendedweekly average≤ 282 lb/dall year
Nitrogen, ammonia total [as N]monthly average≤ 2.73 mg/LMar–Oct
Nitrogen, ammonia total [as N]monthly average≤ 4.54 mg/LJan, Feb, Nov, Dec
Nitrogen, ammonia total [as N]weekly average≤ 4.1 mg/LMar–Oct
Nitrogen, ammonia total [as N]weekly average≤ 6.81 mg/LJan, Feb, Nov, Dec
Nitrogen, ammonia total [as N]monthly average≤ 6 lb/dMar–Oct
Nitrogen, ammonia total [as N]monthly average≤ 9 lb/dJan, Feb, Nov, Dec
Nitrogen, ammonia total [as N]weekly average≤ 9 lb/dMar–Oct
Nitrogen, ammonia total [as N]weekly average≤ 14 lb/dJan, Feb, Nov, Dec
Flow, in conduit or thru treatment plantmonthly averagereport only (MGD)all year
Flow, in conduit or thru treatment plantweekly averagereport only (MGD)all year
Chlorine, total residualmonthly average≤ .012 mg/Lall year
Chlorine, total residualdaily maximum≤ .021 mg/Lall year
Chlorine, total residualmonthly average≤ .03 lb/dall year
Chlorine, total residualdaily maximum≤ .04 lb/dall year
E. coli30-day geometric mean≤ 126 MPN/100mLall year
E. colidaily maximum≤ 349 MPN/100mLall year
E. coli30-day geometric mean≤ 126 MPN/100mLall year
E. colidaily maximum≤ 800 MPN/100mLall year
BOD, 5-day, percent removalmonthly average minimum≥ 65 %all year
Solids, suspended percent removalmonthly average minimum≥ 65 %all year

How strict are these limits?

Cited limits by parameter: South Carolina's rules and the federal ones.