Passage Data · Check a report · Use it from your AI

Component Intertechnologies Inc

Semiconductors And Related Devices, Hadley, Pennsylvania. NPDES permit PA0103926, in force until Jun 30, 2030. Last 12 months: over a limit once (last March 2026), 25 required values missing. Source: EPA ECHO, Oct 22, 2026.

Reports due
About 28 days after each period: outfall 001 form A monthly (3 values), outfall 101 form A monthly (9 values), outfall 201 form A monthly (9 values), outfall 501 form A monthly (4 values), outfall 001 form Y yearly
Last report on file
June 2026
Oct 2024 – Sep 2025
0 values over a limit, 0 required values missing, 8 of 30 reports late

Last 12 months (Oct 1, 2025 – Sep 30, 2026)

Period endingParameterReportedLimitOver by
March 2026Coliform, fecal general, geometric mean494 #/100mL≤ 200 #/100mL147%

Limits in force (31)

ParameterStatisticLimitMonthsOutfall
pHminimum≥ 6 SUall year001
pHmaximum≤ 9 SUall year001
Flow, in conduit or thru treatment plantmonthly averagereport only (MGD)all year001
Perfluorooctanoic acid (PFOA)instantaneous maximumreport only (ng/L)all year001
Perfluorooctanesulfonateinstantaneous maximumreport only (ng/L)all year001
Perfluorobutanesulfonic acid (PFBS)instantaneous maximumreport only (ng/L)all year001
Hexafluoropropylene oxide dimer acid (HFPO-DA)instantaneous maximumreport only (ng/L)all year001
pHinstantaneous minimum≥ 6 SUall year101
pHinstantaneous maximum≤ 9 SUall year101
Iron, dissolved [as Fe]monthly averagereport only (ug/L)all year101
Iron, dissolved [as Fe]daily maximumreport only (ug/L)all year101
Trichloroethylenemonthly average≤ 12.1 ug/Lall year101
Trichloroethylenedaily maximum≤ 18.9 ug/Lall year101
Trichloroethylenemonthly average≤ .003 lb/dall year101
Trichloroethylenedaily maximum≤ .004 lb/dall year101
Flow, in conduit or thru treatment plantmonthly averagereport only (MGD)all year101
pHinstantaneous minimum≥ 6 SUall year201
pHinstantaneous maximum≤ 9 SUall year201
Solids, total suspendedmonthly average≤ 30 mg/Lall year201
Solids, total suspendedinstantaneous maximum≤ 60 mg/Lall year201
Flow, in conduit or thru treatment plantmonthly averagereport only (MGD)all year201
Coliform, fecal generalgeometric mean≤ 200 #/100mLall year201
Coliform, fecal generalinstantaneous maximum≤ 2000 #/100mLall year201
BOD, carbonaceous [5 day, 20 C]monthly average≤ 25 mg/Lall year201
BOD, carbonaceous [5 day, 20 C]instantaneous maximum≤ 50 mg/Lall year201
Temperature, water deg. fahrenheitinstantaneous maximum≤ 110 deg FJan, Feb, Mar, Apr, May, Jun, Aug, Sep, Oct, Nov501
Temperature, water deg. fahrenheitinstantaneous maximum≤ 105.8 deg FDec501
Temperature, water deg. fahrenheitinstantaneous maximum≤ 81.5 deg FJul501
pHinstantaneous minimum≥ 6 SUall year501
pHinstantaneous maximum≤ 9 SUall year501
Flow, in conduit or thru treatment plantmonthly averagereport only (MGD)all year501

How strict are these limits?

Cited limits by parameter: Pennsylvania's rules and the federal ones.

Same industry: the 15 Electronic and Other Electrical Equipment permits in Pennsylvania.

Check this month's numbers Email me before each report is due

· Save this facility as a site · Superfund sites nearby · Your permits on one board

On EPA ECHO: Facility report · DMR history

Your permit document is the final word. As JSON: /api/v1/permits/PA0103926 · MCP: https://passage-data.com/mcp