Water Supply, Saint Marys, Pennsylvania. NPDES permit PA0034789, in force until Jan 31, 2031. Last 12 months: over a limit 5 times (last May 2026), 21 required values missing. Source: EPA ECHO, Oct 22, 2026.
| Period ending | Parameter | Reported | Limit | Over by |
|---|---|---|---|---|
| November 2025 | Manganese, total [as Mn], daily maximum | 3.4 mg/L | ≤ 2 mg/L | 70% |
| November 2025 | Manganese, total [as Mn], monthly average | 2.3 mg/L | ≤ 1 mg/L | 130% |
| March 2026 | Aluminum, total [as Al], monthly average | 1.2 | ≤ 1.1 lb/d | 9% |
| May 2026 | Manganese, total [as Mn], daily maximum | 2.6 mg/L | ≤ 2 mg/L | 30% |
| May 2026 | Manganese, total [as Mn], monthly average | 1.4 mg/L | ≤ 1 mg/L | 40% |
| Parameter | Statistic | Limit | Months |
|---|---|---|---|
| pH | instantaneous minimum | ≥ 6 SU | all year |
| pH | instantaneous maximum | ≤ 9 SU | all year |
| Solids, total suspended | monthly average | ≤ 30 mg/L | all year |
| Solids, total suspended | daily maximum | ≤ 60 mg/L | all year |
| Solids, total suspended | monthly average | report only (lb/d) | all year |
| Solids, total suspended | daily maximum | report only (lb/d) | all year |
| Iron, total [as Fe] | monthly average | ≤ 2 mg/L | all year |
| Iron, total [as Fe] | daily maximum | ≤ 4 mg/L | all year |
| Iron, total [as Fe] | monthly average | report only (lb/d) | all year |
| Iron, total [as Fe] | daily maximum | report only (lb/d) | all year |
| Manganese, total [as Mn] | monthly average | ≤ 1 mg/L | all year |
| Manganese, total [as Mn] | daily maximum | ≤ 2 mg/L | all year |
| Manganese, total [as Mn] | monthly average | report only (lb/d) | all year |
| Manganese, total [as Mn] | daily maximum | report only (lb/d) | all year |
| Aluminum, total [as Al] | monthly average | ≤ .95 mg/L | all year |
| Aluminum, total [as Al] | daily maximum | ≤ 1.8 mg/L | all year |
| Aluminum, total [as Al] | monthly average | ≤ 1.1 lb/d | all year |
| Aluminum, total [as Al] | daily maximum | ≤ 2.2 lb/d | all year |
| Flow, in conduit or thru treatment plant | monthly average | report only (MGD) | all year |
| Chlorine, total residual | monthly average | ≤ .2 mg/L | all year |
| Chlorine, total residual | daily maximum | ≤ 1 mg/L | all year |
Cited limits by parameter: Pennsylvania's rules and the federal ones.
Same industry: the 214 Water Supply permits in Pennsylvania.
· Save this facility as a site · Superfund sites nearby · Your permits on one board
On EPA ECHO: Facility report · DMR history
Your permit document is the final word. As JSON: /api/v1/permits/PA0034789 · MCP: https://passage-data.com/mcp