NPDES permit NH0001473 · Major NON-POTW · administratively continued, expires 2023-06-30 · EPA's file as of 2026-09-19
Check this month's numbers before you fileSign-ups are not open yet. We counted that someone asked — not who, and not which permit — and we open them once enough people do. The check stays free.
This permit expired on 2023-06-30 and is administratively continued: its last limits keep applying until a new permit is issued, and EPA still expects the reports.
Last period with anything received: 2026-08-31.
Reports are due about 15 days after each monitoring period ends (the most common figure among NH permits in EPA's filings — check your permit).
| Outfall | Parameter | Statistic | Limit | Months |
|---|---|---|---|---|
| 001 | Temperature, water deg. fahrenheit | MO AVG | report only | all year |
| 001 | Temperature, water deg. fahrenheit | DAILY MX | <= 95 deg F | all year |
| 001 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 001 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 001 | Oxidants, total residual | INST MAX | <= .2 mg/L | all year |
| 001 | Flow, in conduit or thru treatment plant | MO AVG | <= 40 MGD | all year |
| 001 | Flow, in conduit or thru treatment plant | DAILY MX | <= 40 MGD | all year |
| 001 | Temp. diff. between intake and discharge | MO AVG | report only | all year |
| 001 | Temp. diff. between intake and discharge | DAILY MX | <= 25 deg F | all year |
| 002 | Temperature, water deg. fahrenheit | MO AVG | report only | all year |
| 002 | Temperature, water deg. fahrenheit | DAILY MX | <= 95 deg F | all year |
| 002 | Oxidants, total residual | INST MAX | <= .2 mg/L | all year |
| 002 | Flow, in conduit or thru treatment plant | MO AVG | <= 43.5 MGD | all year |
| 002 | Flow, in conduit or thru treatment plant | DAILY MX | <= 52.2 MGD | all year |
| 002 | Temp. diff. between intake and discharge | MO AVG | report only | all year |
| 002 | Temp. diff. between intake and discharge | DAILY MX | <= 25 deg F | all year |
| 003 | Temperature, water deg. fahrenheit | MO AVG | report only | all year |
| 003 | Temperature, water deg. fahrenheit | DAILY MX | <= 95 deg F | all year |
| 003 | Oxidants, total residual | INST MAX | <= .2 mg/L | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | <= 50.2 MGD | all year |
| 003 | Flow, in conduit or thru treatment plant | DAILY MX | <= 50.2 MGD | all year |
| 003 | Temp. diff. between intake and discharge | MO AVG | report only | all year |
| 003 | Temp. diff. between intake and discharge | DAILY MX | <= 25 deg F | all year |
| 004 | Temperature, water deg. fahrenheit | MO AVG | report only | all year |
| 004 | Temperature, water deg. fahrenheit | DAILY MX | <= 95 deg F | all year |
| 004 | Oxidants, total residual | INST MAX | <= .2 mg/L | all year |
| 004 | Flow, in conduit or thru treatment plant | MO AVG | <= 50.2 MGD | all year |
| 004 | Flow, in conduit or thru treatment plant | DAILY MX | <= 50.2 MGD | all year |
| 004 | Temp. diff. between intake and discharge | MO AVG | report only | all year |
| 004 | Temp. diff. between intake and discharge | DAILY MX | <= 25 deg F | all year |
| 006 | pH | MINIMUM | >= 6.5 SU | all year |
| 006 | pH | MAXIMUM | <= 8 SU | all year |
| 006 | Solids, total suspended | MO AVG | <= 30 mg/L | all year |
| 006 | Solids, total suspended | DAILY MX | <= 100 mg/L | all year |
| 006 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 006 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 006 | Flow, in conduit or thru treatment plant | DAILY MX | report only | all year |
| 011 | pH | MINIMUM | >= 6.5 SU | all year |
| 011 | pH | MAXIMUM | <= 8 SU | all year |
| 011 | Solids, total suspended | MO AVG | <= 30 mg/L | all year |
| 011 | Solids, total suspended | DAILY MX | <= 100 mg/L | all year |
| 011 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 011 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 011 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 011 | Flow, in conduit or thru treatment plant | DAILY MX | report only | all year |
| 015 | pH | MINIMUM | >= 6.5 SU | all year |
| 015 | pH | MAXIMUM | <= 8 SU | all year |
| 015 | Solids, total suspended | MO AVG | <= 30 mg/L | all year |
| 015 | Solids, total suspended | DAILY MX | <= 100 mg/L | all year |
| 015 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 015 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 015 | Flow, in conduit or thru treatment plant | MO AVG | <= 61800 gal/d | all year |
| 015 | Flow, in conduit or thru treatment plant | DAILY MX | <= 85300 gal/d | all year |
| 016 | pH | MINIMUM | >= 6 SU | all year |
| 016 | pH | MAXIMUM | <= 9 SU | all year |
| 016 | Solids, total suspended | MO AVG | <= 30 mg/L | all year |
| 016 | Solids, total suspended | DAILY MX | <= 100 mg/L | all year |
| 016 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 016 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 016 | Copper, total [as Cu] | MO AVG | <= 1 mg/L | all year |
| 016 | Copper, total [as Cu] | DAILY MX | <= 1 mg/L | all year |
| 016 | Iron, total [as Fe] | MO AVG | <= 1 mg/L | all year |
| 016 | Iron, total [as Fe] | DAILY MX | <= 1 mg/L | all year |
| 016 | Flow, in conduit or thru treatment plant | MO AVG | <= 216000 gal/d | all year |
| 016 | Flow, in conduit or thru treatment plant | DAILY MX | <= 360000 gal/d | all year |
| 016 | Nitrogen, Total | DAILY MX | report only | all year |
| 017 | pH | MINIMUM | >= 6 SU | all year |
| 017 | pH | MAXIMUM | <= 9 SU | all year |
| 017 | Solids, total suspended | MO AVG | <= 30 mg/L | all year |
| 017 | Solids, total suspended | DAILY MX | <= 100 mg/L | all year |
| 017 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 017 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 017 | Copper, total [as Cu] | MO AVG | <= 1 mg/L | all year |
| 017 | Copper, total [as Cu] | DAILY MX | <= 1 mg/L | all year |
| 017 | Iron, total [as Fe] | MO AVG | <= 1 mg/L | all year |
| 017 | Iron, total [as Fe] | DAILY MX | <= 1 mg/L | all year |
| 017 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 017 | Flow, in conduit or thru treatment plant | DAILY MX | <= 360000 gal/d | all year |
| 017 | Nitrogen, Total | DAILY MN | report only | all year |
| 018 | pH | MINIMUM | >= 6.5 SU | all year |
| 018 | pH | MAXIMUM | <= 8 SU | all year |
| 018 | Solids, total suspended | MO AVG | <= 15 mg/L | all year |
| 018 | Solids, total suspended | DAILY MX | <= 20 mg/L | all year |
| 018 | Oil & Grease | MO AVG | <= 15 mg/L | all year |
| 018 | Oil & Grease | DAILY MX | <= 20 mg/L | all year |
| 018 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 018 | Flow, in conduit or thru treatment plant | DAILY MX | report only | all year |
| 020 | Flow, in conduit or thru treatment plant | DAILY MX | <= 108000 gal/d | all year |
| 021 | Flow, in conduit or thru treatment plant | DAILY MX | <= 108000 gal/d | all year |
| SUM | Flow rate | MO AVG | <= 41.8 MGD | Apr, May, Jun, Jul, Aug, Sep, Oct |
| SUM | Flow rate | MO AVG | <= 83.6 MGD | Jan, Feb, Mar, Nov, Dec |
| SUM | Flow rate | DAILY MX | <= 125.8 MGD | Apr, May, Jun, Jul, Aug, Sep, Oct |
| SUM | Flow rate | DAILY MX | <= 125.8 MGD | Jan, Feb, Mar, Nov, Dec |
| SUM | Flow rate | ROLL AVG | <= 30.19 MGD | all year |
| SUM | Screen Efficiency | ROLL AVG | <= 24 % | all year |
Built from EPA's ECHO bulk files. EPA's file, not the permit document, is the source: read your permit. Check a report before you file it · All states