NPDES permit FL0028061 · Major POTW · effective, expires 2030-02-09 · EPA's file as of 2026-09-19
Check this month's numbers before you fileSign-ups are not open yet. We counted that someone asked — not who, and not which permit — and we open them once enough people do. The check stays free.
Last period with anything received: 2026-07-31.
Reports are due about 28 days after each monitoring period ends (read off this permit's own late-day counts in EPA's filings).
| Outfall | Parameter | Statistic | Limit | Months |
|---|---|---|---|---|
| 003 | Turbidity | MAXIMUM | report only | all year |
| 003 | Plant capacity fact. percent of capacity | MO AVG | report only | all year |
| 003 | Oxygen, dissolved [DO] | MINIMUM | >= 4.1 mg/L | all year |
| 003 | pH | MINIMUM | >= 6.5 SU | all year |
| 003 | pH | MAXIMUM | <= 8.5 SU | all year |
| 003 | Solids, total suspended | WKLY AVG | <= 7.5 mg/L | all year |
| 003 | Solids, total suspended | MAXIMUM | <= 10 mg/L | all year |
| 003 | Solids, total suspended | MO AVG | <= 6.25 mg/L | all year |
| 003 | Solids, total suspended | MAXIMUM | <= 5 mg/L | all year |
| 003 | Solids, total suspended | MO AVG | report only | all year |
| 003 | Solids, total suspended | ANNL AVG | <= 5 mg/L | all year |
| 003 | Nitrogen, total [as N] | WKLY AVG | <= 4.5 mg/L | all year |
| 003 | Nitrogen, total [as N] | MAXIMUM | <= 6 mg/L | all year |
| 003 | Nitrogen, total [as N] | MO AVG | <= 3.75 mg/L | all year |
| 003 | Nitrogen, total [as N] | MO TOTAL | report only | all year |
| 003 | Nitrogen, total [as N] | ANNL TOT | report only | all year |
| 003 | Nitrogen, total [as N] | 5 YR AVG | report only | all year |
| 003 | Nitrogen, total [as N] | ANNL AVG | <= 3 mg/L | all year |
| 003 | Phosphorus, total [as P] | MO AVG | report only | all year |
| 003 | Phosphorus, total [as P] | MAXIMUM | report only | all year |
| 003 | Enterococci: group D, MF trans, M-E, EIA | MAXIMUM | <= 276 #/100mL | all year |
| 003 | Enterococci: group D, MF trans, M-E, EIA | MO GEOMN | <= 35 #/100mL | all year |
| 003 | Ultraviolet light intensity | MINIMUM | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | ANNL AVG | <= 10 MGD | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | ANNL AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | ANNL AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | ANNL AVG | <= 11 MGD | all year |
| 003 | Flow, in conduit or thru treatment plant | QTR ROLL | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 003 | Flow, in conduit or thru treatment plant | ANNL AVG | <= 10 MGD | all year |
| 003 | Chlorine, total residual | MAXIMUM | <= .01 mg/L | all year |
| 003 | Chlorine, total residual | MINIMUM | >= 1 mg/L | all year |
| 003 | % of fecal coliform samples < detectable | MO AVG | <= 75 % | all year |
| 003 | Ultraviolet light transmittance | MINIMUM | report only | all year |
| 003 | Ultraviolet light dosage | MINIMUM | >= 100 mW-sec/cm2 | all year |
| 003 | Mercury, total recoverable | MAXIMUM | <= .025 ug/L | all year |
| 003 | Coliform, fecal general | MAXIMUM | <= 25 #/100mL | all year |
| 003 | BOD, carbonaceous [5 day, 20 C] | WKLY AVG | <= 7.5 mg/L | all year |
| 003 | BOD, carbonaceous [5 day, 20 C] | MAXIMUM | <= 10 mg/L | all year |
| 003 | BOD, carbonaceous [5 day, 20 C] | MO AVG | <= 6.25 mg/L | all year |
| 003 | BOD, carbonaceous [5 day, 20 C] | MO AVG | report only | all year |
| 003 | BOD, carbonaceous [5 day, 20 C] | ANNL AVG | <= 5 mg/L | all year |
| 003 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 003 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 003 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 003 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
| 003 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
| 003 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
| 004 | Overflows | MO TOTAL | report only | all year |
| 004 | Duration of discharge | MO TOTAL | report only | all year |
| 005 | Overflows | MO TOTAL | report only | all year |
| 005 | Duration of discharge | MO TOTAL | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | ANNL AVG | <= 10 MGD | all year |
| 006 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | ANNL AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | ANNL AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | MO AVG | report only | all year |
| 006 | Flow, in conduit or thru treatment plant | ANNL AVG | <= 4 MGD | all year |
| 006 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 006 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 006 | LC50 Static Renewal 96Hr Acute Ceriodaphnia dubia | MINIMUM | >= 100 % | all year |
| 006 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
| 006 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
| 006 | LC50 Static Renewal 96Hr Acute Cyprinella leedsi | MINIMUM | >= 100 % | all year |
Built from EPA's ECHO bulk files. EPA's file, not the permit document, is the source: read your permit. Check a report before you file it · All states