Passage Data · Cited limits by place · Use it from your AI

TSS in West Virginia (US-WV): 40 CFR Part 413 — Electroplating point source category

14 rows for tss in this instrument. Every instrument for tss in West Virginia

United States (US): 14 rows

Effluent: 14 rows

40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05 · 14 limits
Every row: discharge to a sewer (pretreatment); existing sources (PSES); (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
ValueStatisticApplies whenCite
20.0 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.24 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.44 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart E—Coatings Subcategory
table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.54 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart F—Chemical Etching and Milling Subcategory
table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.64 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart G—Electroless Plating Subcategory
table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.74 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above
20.0 mg/Ldaily maximumthe discharge is of the Subpart H—Printed Circuit Board Subcategory
table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.84 (PSES)
TSS 20.0 13.4
13.4 mg/L—as aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.