ValueStatisticApplies whenCite
6.9 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
40 CFR 419.12 (BPT)
Oil and grease 6.9 3.7
3.7 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.015 kilograms per cubic meter of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.12 (BPT)
Oil and grease 0.015 0.008
0.008 kilograms per cubic meter of flowmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.12 (BPT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
6.9 Kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
40 CFR 419.14 (BCT)
Oil and Grease 6.9 3.7
3.7 Kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.015 kilograms per m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best conventional pollutant control technology by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation allowed fo…
40 CFR 419.14 (BCT)
Oil and grease 0.015 0.008
0.008 kilograms per m³ of flowmonthly averageas aboveas above
15. kilograms per 1,000 (m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.14 (BCT)
Oil and grease 15. 8.
8. kilograms per 1,000 (m³ of flowmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Topping Subcategory
existing sources (PSES)
40 CFR 419.15 (PSES)
Oil and Grease 100
3.6 kilograms per cubic meter of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.16 (NSPS)
Oil and grease 3.6 1.9
1.9 kilograms per cubic meter of flowmonthly averageas aboveas above
0.015 kilograms per cubic meter of flowdaily maximumdischarge to surface water
the discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.16 (NSPS)
Oil and grease 0.015 0.008
0.008 kilograms per cubic meter of flowmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Topping Subcategory
new sources (PSNS)
(a) The following standards apply to the total refinery flow contribution to the POTW:
40 CFR 419.17 (PSNS)
Oil and grease 100
8.4 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
40 CFR 419.22 (BPT)
Oil and grease 8.4 4.5
4.5 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.22 (BPT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
8.4 kilograms per 1,000 (m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart B—Cracking Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.24 (BCT)
Oil and grease 8.4 4.5
4.5 kilograms per 1,000 (m³ of feedstockmonthly averageas aboveas above
15 kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart B—Cracking Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.24 (BCT)
Oil and grease 15 8
8 kilograms per 1,000 m³ of flowmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Cracking Subcategory
new sources (PSNS)
40 CFR 419.25 (PSNS)
Oil and grease 100
4.8 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart B—Cracking Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.26 (NSPS)
oil and grease 4.8 2.6
2.6 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Cracking Subcategory
new sources (PSNS)
(a) The following standards apply to the total refinery flow contribution to the POTW.
40 CFR 419.27 (PSNS)
Oil and grease 100
11.1 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
40 CFR 419.32 (BPT)
Oil and grease 11.1 5.9
5.9 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.32 (BPT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
11.1 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.34 (BCT)
Oil and grease 11.1 5.9
5.9 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.34 (BCT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Petrochemical Subcategory
existing sources (PSES)
40 CFR 419.35 (PSES)
Oil and grease 100
6.6 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart C—Petrochemical Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.36 (NSPS)
Oil and grease 6.6 3.5
3.5 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Petrochemical Subcategory
new sources (PSNS)
(a) The following standards apply to the total refinery flow contribution to the POTW:
40 CFR 419.37 (PSNS)
Oil and grease 100
16.2 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
40 CFR 419.42 (BPT)
Oil and grease 16.2 8.5
8.5 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.42 (BPT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
16.2 Metric units (kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart D—Lube Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.44 (BCT)
Oil and Grease 16.2 8.5
8.5 Metric units (kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. Metric unit (kilograms per 1,000 m³ of flow)daily maximumdischarge to surface water
the discharge is of the Subpart D—Lube Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.44 (BCT)
Oil and grease 15. 8.
8. Metric unit (kilograms per 1,000 m³ of flow)monthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Lube Subcategory
existing sources (PSES)
40 CFR 419.45 (PSES)
Oil and grease 100
10.5 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart D—Lube Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.46 (NSPS)
Oil and grease 10.5 5.6
5.6 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Lube Subcategory
new sources (PSNS)
(a) The following standards apply to the total refinery flow contribution to the POTW:
40 CFR 419.47 (PSNS)
Oil and grease 100
17.1 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
40 CFR 419.52 (BPT)
Oil and grease 17.1 9.1
9.1 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of flowdaily maximumdischarge to surface water
the discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.52 (BPT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
17.1 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart E—Integrated Subcategory
existing sources (BCT)
(a) Any existing point subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.54 (BCT)
Oil and grease 17.1 9.1
9.1 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
15. kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart E—Integrated Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.54 (BCT)
Oil and grease 15. 8.
8. kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart E—Integrated Subcategory
existing sources (PSES)
40 CFR 419.55 (PSES)
Oil and grease 100
12.6 kilograms per 1,000 m³ of feedstockdaily maximumdischarge to surface water
the discharge is of the Subpart E—Integrated Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.56 (NSPS)
Oil and grease 12.6 6.7
6.7 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart E—Integrated Subcategory
new sources (PSNS)
(a) The following standards apply to the total refinery flow contribution to the POTW:
40 CFR 419.57 (PSNS)
Oil and grease 100