Passage Data · Cited limits by place · Use it from your AI

Chromium in West Virginia (US-WV): West Virginia 47CSR2 Requirements Governing Water Quality Standards

9 rows for chromium in this instrument. Every instrument for chromium in West Virginia

West Virginia (US-WV): 9 rows

Surface water: 9 rows

West Virginia 47CSR2 Requirements Governing Water Quality Standards · the rule effective July 1, 2026 (authorized by SB256, passed 2/23/2026; Secretary of State final filing 3/4/2026). US EPA's posting in effect for CWA purposes… · 9 guidelines
Every row: receiving water: freshwater
ParameterValueStatisticApplies whenCite
Chromium III (dissolved)CrIII = e(0.8190[ln(hardness)]+3.7256) x CF5 µg/L1-hour averageCategory B1 (warm water fishery streams) and B4 (wetlands) waters (47CSR2 §6.3)47CSR2 Appendix E Table 1, 8.9.2 · p. 39
Chromium III (dissolved)CrIII = e(0.8190[ln(hardness)]+3.7256) x CF5 µg/L1-hour averageCategory B2 (trout waters) (47CSR2 §6.3)as above
Chromium III (dissolved)CrIII = e(0.8190[ln(hardness)]+0.6848) x CF5 µg/L4-day averageCategory B1 (warm water fishery streams) and B4 (wetlands) waters (47CSR2 §6.3)47CSR2 Appendix E Table 1, 8.9.3 · p. 39
Chromium III (dissolved)CrIII = e(0.8190[ln(hardness)]+0.6848) x CF5 µg/L4-day averageCategory B2 (trout waters) (47CSR2 §6.3)as above
Chromium VI (dissolved)16 µg/L1-hour averageCategory B1 (warm water fishery streams) and B4 (wetlands) waters (47CSR2 §6.3)47CSR2 Appendix E Table 1, 8.9.1 · p. 39
Chromium VI (dissolved)11 µg/L4-day averageas aboveas above
Chromium VI (dissolved)16 µg/L1-hour averageCategory B2 (trout waters) (47CSR2 §6.3)as above
Chromium VI (dissolved)7.2 µg/L4-day averageas aboveas above
Chromium VI (dissolved)50 µg/Lannual averageCategory A waters, public water supply (human health through drinking water and fish consumption; 47CSR2 §6.2)as above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.