Passage Data · Cited limits by place · Use it from your AI

Nickel limits and guidelines in Washington (US-WA)

2,109 cited rows from 19 instruments, Washington's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Washington (US-WA) and United States. Everything held for Washington

Washington: surface water 6 · United States: drinking water 8, surface water 9, effluent 2,065, leachate 1, soil 19, product 1

Washington (US-WA): 6 rows

Surface water: 6 rows

Washington WAC 173-201A Water Quality Standards for Surface Waters · aquatic life: WAC 173-201A-240(5)(b) Table 240 as US EPA posts it in effect for CWA purposes (effective December 20, 2024; WAC print of 9/12/2023); human… · 6 guidelines
ValueStatisticApplies whenCite
(t,c,dd)1-hour averagereceiving water: freshwater
hardness-dependent: the criterion is the equation of note t, of the receiving water's hardness
WAC 173-201A-240(5)(b) Table 240 (aquatic life, in effect for CWA purposes) · p. 3
(u,d,dd)4-day averagereceiving water: freshwater
hardness-dependent: the criterion is the equation of note u, of the receiving water's hardness
as above
74.0 (c,ll,dd) µg/L1-hour averagereceiving water: marineas above
8.2 (d,ll,dd) µg/L4-day averageas aboveas above
80 µg/L—all surface waters of the state with fish harvesting, recreation or (water & organisms) domestic water supply uses; human health criteria apply in fresh and marine waters alike (WAC 173-201A-240(5)(b))WAC 173-201A-240(5)(b) Table 240 (human health)
Nickel 7440020 (a,f,v) (b,f,w) 74 (a,f,g) 8.2 (b,f,g) 80 100
100 µg/L—as aboveas above

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

United States (US): 2,103 rows

Drinking water: 8 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water · November 2024 · 8 guidelines
Every row: Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024
ParameterValueCite
Nickel Soluble Salts390 µg/Lsource
Nickel Acetate220 µg/Las above
Nickel Carbonate220 µg/Las above
Nickel Carbonyl0.022 µg/Las above
Nickel Hydroxide200 µg/Las above
Nickel Oxide200 µg/Las above
Nickel Refinery Dust220 µg/Las above
Nickel Subsulfide0.045 µg/Las above

Surface water: 9 rows

EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC) · EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year · 6 guidelines
Every row: EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
ValueApplies whenCite
470 µg/Lreceiving water: freshwater
Freshwater CMC (acute): criterion maximum concentration, acute
corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness)
National Recommended Aquatic Life Criteria table
Nickel (P) 7440020 470 52 74 8.2 1995
exp{0.8460 [ln(hardness)] + 2.255} × CF, CF = 0.998 µg/Lreceiving water: freshwater
Freshwater CMC (acute), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here
Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-Dependent
Nickel 0.8460 2.255 0.8460 0.0584 0.998 0.997
52 µg/Lreceiving water: freshwater
Freshwater CCC (chronic): criterion continuous concentration, chronic
corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness)
National Recommended Aquatic Life Criteria table
Nickel (P) 7440020 470 52 74 8.2 1995
exp{0.8460 [ln(hardness)] + 0.0584} × CF, CF = 0.997 µg/Lreceiving water: freshwater
Freshwater CCC (chronic), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here
Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-Dependent
Nickel 0.8460 2.255 0.8460 0.0584 0.998 0.997
74 µg/Lreceiving water: marine
Saltwater CMC (acute): criterion maximum concentration, acute
National Recommended Aquatic Life Criteria table
Nickel (P) 7440020 470 52 74 8.2 1995
8.2 µg/Lreceiving water: marine
Saltwater CCC (chronic): criterion continuous concentration, chronic
as above
EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only) · EPA web table (fetched 2026-10-09); each criterion carries its publication year · 3 guidelines
Every row: EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
ValueApplies whenCite
610 µg/Lreceiving water: freshwater
consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)
National Recommended Water Quality Criteria — Human Health Criteria Table
Nickel (P) 7440020 610 4,600 1998
4,600 µg/Lreceiving water: freshwater
consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt)
as above
4,600 µg/Lreceiving water: marine
consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt)
as above

Effluent: 2,065 rows

40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05 · 28 limits, 10 shown
Every row: discharge to a sewer (pretreatment); existing sources (PSES)
ParameterValueStatisticApplies whenCite
Ni4.1 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
Ni 4.1 2.6
Ni2.6 mg/L—as aboveas above
Ni160 mg/sq m-Operationdaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.14 (PSES)
Ni 160 100
Ni100 mg/sq m-Operation—as aboveas above
Ni4.1 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.24 (PSES)
Ni 4.1 2.6
Ni2.6 mg/L—as aboveas above
Ni160 mg/sq m-Operationdaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.24 (PSES)
Ni 160 100
Ni100 mg/sq m-Operation—as aboveas above
Ni4.1 mg/Ldaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.44 (PSES)
Ni 4.1 2.6
Ni2.6 mg/L—as aboveas above

All 28 rows from 40 CFR Part 413 — Electroplating point source category

40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers · eCFR as of 2026-08-01 · 8 limits
Every row: (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i; discharge to surface water
ParameterValueStatisticApplies whenCite
Total Nickel3,980 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Nickel 3,980 1,690
Total Nickel3,980 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Nickel 3,980 1,690
Total Nickel1,690 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Nickel 3,980 1,690
Total Nickel1,690 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Nickel 3,980 1,690
Total Nickel3,980 µg/Ldaily maximumthe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Total Nickel 3,980 1,690
Total Nickel3,980 µg/Ldaily maximumthe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Total Nickel 3,980 1,690
Total Nickel1,690 µg/Lmonthly averagethe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Total Nickel 3,980 1,690
Total Nickel1,690 µg/Lmonthly averagethe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Total Nickel 3,980 1,690
40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01 · 59 limits, 10 shown
ParameterValueStatisticApplies whenCite
Nickel (T)0.014 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (BPT)
table: Subpart F—Chlor-Alkali Diaphragm Cells
40 CFR 415.62 (BPT)
Nickel (T) 0.014 0.0056
Nickel (T)0.0056 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Nickel (T)0.0097 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (BAT)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.63 (BAT)
Nickel (T) 0.0097 0.0037
Nickel (T)0.0037 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Nickel (T)1.6 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (PSES)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.64 (PSES)
Nickel (T) 1.6 0.64
Nickel (T)0.64 mg/Lmonthly averageas aboveas above
Nickel (T)0.011 Kg/kkg (or pounds per 1,000 lb) of productmonthly averagedischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
existing sources (BPT)
table: Subpart H—Hydrofluoric Acid
40 CFR 415.82 (BPT)
Nickel (T) k0.036 0.011
Nickel (T)0.020 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
existing sources (BAT)
table: Subpart H—Hydrofluoric Acid
40 CFR 415.83 (BAT)
Nickel (T) 0.020 0.0060
Nickel (T)0.0060 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Nickel (T)0.020 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
table: Subpart H—Hydrofluoric Acid
40 CFR 415.85 (NSPS)
Nickel (T) 0.020 0.0060

All 59 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category

40 CFR Part 420 — Iron and steel manufacturing point source category · eCFR as of 2026-10-05 · 190 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart H—Salt Bath Descaling Subcategory; existing sources (BPT); table: Subpart H
ValueStatisticApplies whenCite
0.00263 Kg/kkg (pounds per 1,000 lb) of productdaily maximum(a) Salt bath descaling, oxidizing —(1) Batch, sheet and plate.40 CFR 420.82 (BPT)
Nickel 0.00263 0.000876
0.000876 Kg/kkg (pounds per 1,000 lb) of productmonthly averageas aboveas above
0.00158 Kg/kkg (pounds per 1,000 lb) of productdaily maximum(2) Batch, rod and wire.40 CFR 420.82 (BPT)
Nickel 0.00158 0.000526
0.000526 Kg/kkg (pounds per 1,000 lb) of productmonthly averageas aboveas above
0.00638 Kg/kkg (pounds per 1,000 lb) of productdaily maximum(3) Batch, pipe and tube.40 CFR 420.82 (BPT)
Nickel 0.00638 0.00213
0.00213 Kg/kkg (pounds per 1,000 lb) of productmonthly averageas aboveas above
0.00124 Kg/kkg (pounds per 1,000 lb) of productdaily maximum(4) Continuous.40 CFR 420.82 (BPT)
Nickel 0.00124 0.000413
0.000413 Kg/kkg (pounds per 1,000 lb) of productmonthly averageas aboveas above
0.00122 Kg/kkg (pounds per 1,000 lb) of productdaily maximum(b) Salt bath descaling, reducing —(1) Batch.40 CFR 420.82 (BPT)
Nickel 0.00122 0.000407
0.000407 Kg/kkg (pounds per 1,000 lb) of productmonthly averageas aboveas above

All 190 rows from 40 CFR Part 420 — Iron and steel manufacturing point source category

40 CFR Part 421 — Nonferrous metals manufacturing point source category · eCFR as of 2026-10-05 · 794 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory; existing sources (BAT); table: BAT Effluent Limitations
ValueStatisticApplies whenCite
.075 mg/kg (pounds per million pounds) of paste produceddaily maximum(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control40 CFR 421.23 (BAT)
Nickel .075 .050
.050 mg/kg (pounds per million pounds) of paste producedmonthly averageas aboveas above
.115 mg/kg (pounds per million pounds) of anodes castdaily maximum(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.40 CFR 421.23 (BAT)
Nickel .115 .077
.077 mg/kg (pounds per million pounds) of anodes castmonthly averageas aboveas above
2.378 mg/kg (pounds per million pounds) of anodes bakeddaily maximum(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).40 CFR 421.23 (BAT)
Nickel 2.378 1.600
1.600 mg/kg (pounds per million pounds) of anodes bakedmonthly averageas aboveas above
.028 mg/kg (pounds per million pounds) of anodes bakeddaily maximum(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).40 CFR 421.23 (BAT)
Nickel .028 .019
.019 mg/kg (pounds per million pounds) of anodes bakedmonthly averageas aboveas above
.402 mg/kg (pounds per million pounds) of anodes bakeddaily maximum(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).40 CFR 421.23 (BAT)
Nickel .402 .270
.270 mg/kg (pounds per million pounds) of anodes bakedmonthly averageas aboveas above

All 794 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category

40 CFR Part 433 — Metal finishing point source category · eCFR as of 2026-10-05 · 10 limits
Every row: the discharge is of the Subpart A—Metal Finishing Subcategory
ParameterValueStatisticApplies whenCite
Nickel (T)3.98 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: BPT Effluent Limitations
40 CFR 433.13 (BPT)
Nickel (T) 3.98 2.38
Nickel (T)2.38 mg/Lmonthly averageas aboveas above
Nickel (T)3.98 mg/Ldaily maximumdischarge to surface water
existing sources (BAT)
table: BAT Effluent Limitations
40 CFR 433.14 (BAT)
Nickel (T) 3.98 2.38
Nickel (T)2.38 mg/Lmonthly averageas aboveas above
Nickel (T)3.98 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers
40 CFR 433.15 (PSES)
Nickel (T) 3.98 2.38
Nickel (T)2.38 mg/Lmonthly averageas aboveas above
Nickel (T)3.98 mg/Ldaily maximumdischarge to surface water
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following performance standards:
table: NSPS
40 CFR 433.16 (NSPS)
Nickel (T) 3.98 2.38
Nickel (T)2.38 mg/Lmonthly averageas aboveas above
Nickel (T)3.98 mg/Ldaily maximumdischarge to a sewer (pretreatment)
new sources (PSNS)
table: PSNS
40 CFR 433.17 (PSNS)
Nickel (T) 3.98 2.38
Nickel (T)2.38 mg/Lmonthly averageas aboveas above
40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05 · 28 limits, 10 shown
Every row: discharge to surface water
ValueStatisticApplies whenCite
3.95 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.11 (BPT)
Nickel 3.95 1.45
1.45 mg/Lmonthly averageas aboveas above
0.794 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
new sources (NSPS)
table: Performance Standards
40 CFR 437.14 (NSPS)
Nickel 0.794 0.309
0.309 mg/Lmonthly averageas aboveas above
3.95 mg/Ldaily maximumthe discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
40 CFR 437.42 (BPT)
Nickel 3.95 1.45
1.45 mg/Lmonthly averageas aboveas above
3.95 mg/Ldaily maximumthe discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
as above
1.45 mg/Lmonthly averageas aboveas above
3.95 mg/Ldaily maximumthe discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
as above
1.45 mg/Lmonthly averageas aboveas above

All 28 rows from 40 CFR Part 437 — The centralized waste treatment point source category

40 CFR Part 440 — Ore mining and dressing point source category · eCFR as of 2026-10-05 · 4 limits
Every row: discharge to surface water; existing sources (BPT)
ParameterValueStatisticApplies whenCite
Ni.2 mg/Ldaily maximumthe discharge is of the Subpart D—Mercury Ore Subcategory
(a) The concentration of pollutants discharged in mine drainage from mines, either open-pit or underground, operated for the production of mercury ores shall not exceed the following limitations:
40 CFR 440.42 (BPT)
Ni .2 .1
Ni.1 mg/Lmonthly averageas aboveas above
Ni.2 mg/Ldaily maximumthe discharge is of the Subpart E—Titanium Ore Subcategory
(b) The concentration of pollutants discharged from mills beneficiating titanium ores by electrostatic methods, magnetic and physical methods, or flotation methods shall not exceed:
40 CFR 440.52 (BPT)
Ni .2 .1
Ni.1 mg/Lmonthly averageas aboveas above
40 CFR Part 442 — Transportation equipment cleaning point source category · eCFR as of 2026-10-05 · 2 limits
Every row: the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos
ValueStatisticApplies whenCite
0.58 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: Table—Effluent Limitations
40 CFR 442.31 (BPT)
Nickel 0.58
0.58 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Table—Pretreatment Standards
40 CFR 442.35 (PSES)
Nickel 0.58
40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05 · 112 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Cadmium Subcategory; existing sources (BPT); table: BPT Effluent Limitations
ValueStatisticApplies whenCite
5.18 mg/kg of cadmiumdaily maximum(1) Subpart A—Pasted and Pressed Powder Anodes.40 CFR 461.11 (BPT)
Nickel 5.18 3.43
3.43 mg/kg of cadmiummonthly averageas aboveas above
1,338.2 mg/kg of cadmiumdaily maximum(2) Subpart A—Electrodeposited Anodes.40 CFR 461.11 (BPT)
Nickel 1,338.2 885.2
885.2 mg/kg of cadmiummonthly averageas aboveas above
1,916.2 mg/kg of cadmiumdaily maximum(3) Subpart A—Impregnated Anodes.40 CFR 461.11 (BPT)
Nickel 1,916.2 1,267.5
1,267.5 mg/kg of cadmiummonthly averageas aboveas above
1,092.5 mg/kg of nickel applieddaily maximum(4) Subpart A—Nickel Electrodeposited Cathodes.40 CFR 461.11 (BPT)
Nickel 1,092.5 722.6
722.6 mg/kg of nickel appliedmonthly averageas aboveas above
3,148.8 mg/kg of nickel applieddaily maximum(5) Subpart A—Nickel Impregnated Cathodes.40 CFR 461.11 (BPT)
Nickel 3,148.8 2,082.8
2,082.8 mg/kg of nickel appliedmonthly averageas aboveas above

All 112 rows from 40 CFR Part 461 — Battery manufacturing point source category

40 CFR Part 466 — Porcelain enameling point source category · eCFR as of 2026-10-05 · 62 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Steel Basis Material Subcategory
ValueStatisticApplies whenCite
56.46 mg/m² of area processed or coateddaily maximumexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
40 CFR 466.11 (BPT)
Nickel 56.46 11.43 40.05 8.11
11.43 mg/m² of area processed or coateddaily maximumexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
40.05 mg/m² of area processed or coatedmonthly averageexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
as above
8.11 mg/m² of area processed or coatedmonthly averageexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
56.50 mg/m² of area processed or coateddaily maximumexisting sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Metal preparation
40 CFR 466.12 (BAT)
Nickel 56.50 1.78 40.05 1.26
1.78 mg/m² of area processed or coateddaily maximumexisting sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Coating operation
as above
40.05 mg/m² of area processed or coatedmonthly averageexisting sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Metal preparation
as above
1.26 mg/m² of area processed or coatedmonthly averageexisting sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Coating operation
as above
12.0 mg/m² of area processed or coateddaily maximumnew sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Metal preparation
40 CFR 466.13 (NSPS)
Nickel 12.0 1.51 6.3 0.79
1.51 mg/m² of area processed or coateddaily maximumnew sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Coating operation
as above

All 62 rows from 40 CFR Part 466 — Porcelain enameling point source category

40 CFR Part 468 — Copper forming point source category · eCFR as of 2026-10-05 · 170 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Copper Forming Subcategory; existing sources (BPT)
ValueStatisticApplies whenCite
0.197 mg/off-kg of copper or copper alloy hot rolleddaily maximum(a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Nickel 0.197 0.130
0.130 mg/off-kg of copper or copper alloy hot rolledmonthly averageas aboveas above
0.727 mg/off-kg of copper or copper alloy cold rolleddaily maximum(b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Nickel 0.727 0.481
0.481 mg/off-kg of copper or copper alloy cold rolledmonthly averageas aboveas above
0.163 mg/off-kg of copper or copper alloy drawndaily maximum(c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Nickel 0.163 0.107
0.107 mg/off-kg of copper or copper alloy drawnmonthly averageas aboveas above
4.878 mg/off-kg of copper or copper alloy heat treateddaily maximum(d) Subpart A—Solution Heat Treatment BPT Effluent Limitations.40 CFR 468.11 (BPT)
Nickel 4.878 3.227
3.227 mg/off-kg of copper or copper alloy heat treatedmonthly averageas aboveas above
0.003 mg/off-kg of copper or copper alloy heat treated on an extrusion pressdaily maximum(e) Subpart A—Extrusion Heat Treatment BPT Effluent Limitations.40 CFR 468.11 (BPT)
Nickel 0.003 0.002
0.002 mg/off-kg of copper or copper alloy heat treated on an extrusion pressmonthly averageas aboveas above

All 170 rows from 40 CFR Part 468 — Copper forming point source category

40 CFR Part 471 — Nonferrous metals forming and metal powders point source category · eCFR as of 2026-10-05 · 598 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart C—Nickel-Cobalt Forming Subcategory; existing sources (BPT); table: Subpart C—BPT
ValueStatisticApplies whenCite
0.327 mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsionsdaily maximum(b) Rolling spent emulsions.40 CFR 471.31 (BPT)
Nickel 0.327 0.216
0.216 mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsionsmonthly averageas aboveas above
7.24 mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with waterdaily maximum(c) Rolling contact cooling water.40 CFR 471.31 (BPT)
Nickel 7.24 4.79
4.79 mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with watermonthly averageas aboveas above
0.183 mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsionsdaily maximum(f) Drawing spent emulsions.40 CFR 471.31 (BPT)
Nickel 0.183 0.121
0.121 mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsionsmonthly averageas aboveas above
0.160 mg/off-kg (pounds per million off-pounds) of nickel-cobalt heat treateddaily maximum(h) Extrusion press or solution heat treatment contact cooling water.40 CFR 471.31 (BPT)
Nickel 0.160 0.106
0.106 mg/off-kg (pounds per million off-pounds) of nickel-cobalt heat treatedmonthly averageas aboveas above
0.446 mg/off-kg (pounds per million off-pounds) of nickel-cobalt extrudeddaily maximum(i) Extrusion press hydraulic fluid leakage.40 CFR 471.31 (BPT)
Nickel 0.446 0.295
0.295 mg/off-kg (pounds per million off-pounds) of nickel-cobalt extrudedmonthly averageas aboveas above

All 598 rows from 40 CFR Part 471 — Nonferrous metals forming and metal powders point source category

Leachate: 1 row

40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 1 limit
ValueStatisticApplies whenCite
11 mg/L TCLPinstantaneous(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard
Nickel 7440-02-0 3.98 11 mg/l TCLP

Soil: 19 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil · November 2024 · 19 guidelines, 10 shown
ParameterValueApplies whenCite
Nickel Soluble Salts1400 mg/kgResident Soil (mg/kg)source
Nickel Soluble Salts17000 mg/kgIndustrial Soil (mg/kg)as above
Nickel Soluble Salts26 mg/kgProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Nickel Acetate670 mg/kgResident Soil (mg/kg)as above
Nickel Acetate8100 mg/kgIndustrial Soil (mg/kg)as above
Nickel Acetate0.045 mg/kgProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Nickel Carbonate670 mg/kgResident Soil (mg/kg)as above
Nickel Carbonate8100 mg/kgIndustrial Soil (mg/kg)as above
Nickel Carbonyl820 mg/kgResident Soil (mg/kg)as above
Nickel Carbonyl11000 mg/kgIndustrial Soil (mg/kg)as above

All 19 rows from US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil

Product: 1 row

40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 1 limit
ValueStatisticApplies whenCite
3.98 mg/Lcomposite sample(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard
Nickel 7440-02-0 3.98 11 mg/l TCLP

This page shows 149 of 2,109 rows: every instrument, each with its first 10 rows or all of them. All 2,109 as JSON, 200 a page.

What was searched

69 instruments we hold for Washington (US-WA) and United States, for 19 names matching “nickel” (each in the JSON). 19 have a row, in the tables above; 50 have none.

50 instruments with no row for nickel
  1. 40 CFR 52.21 — Prevention of significant deterioration of air quality · eCFR 2026-08-01
  2. 40 CFR 63.2 — Definitions (major source of hazardous air pollutants) · eCFR 2026-08-01
  3. 40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity… · eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)
  4. 40 CFR Part 50, National Primary and Secondary Ambient Air Quality Standards, §§ 50.4–50.21 (eCFR as of 2026-08-01) · 90 FR 4651, Jan. 16, 2025
  5. 40 CFR Part 133 — Secondary Treatment Regulation · eCFR as of 2026-10-05
  6. 40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01
  7. 40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01
  8. 40 CFR Part 405 — Dairy products processing point source category · eCFR as of 2026-10-05
  9. 40 CFR Part 406 — Grain mills point source category · eCFR as of 2026-10-05
  10. 40 CFR Part 407 — Canned and preserved fruits and vegetables processing point source category · eCFR as of 2026-10-05
  11. 40 CFR Part 408 — Canned and preserved seafood processing point source category · eCFR as of 2026-10-05
  12. 40 CFR Part 409 — Sugar processing point source category · eCFR as of 2026-10-05
  13. 40 CFR Part 410 — Textile mills point source category · eCFR as of 2026-10-05
  14. 40 CFR Part 411 — Cement manufacturing point source category · eCFR as of 2026-10-05
  15. 40 CFR Part 412 — Concentrated animal feeding operations (CAFO) point source category · eCFR as of 2026-10-05
  16. 40 CFR Part 417 — Soap and detergent manufacturing point source category · eCFR as of 2026-10-05
  17. 40 CFR Part 418 — Fertilizer manufacturing point source category · eCFR as of 2026-08-01
  18. 40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05
  19. 40 CFR Part 422 — Phosphate manufacturing point source category · eCFR as of 2026-08-01
  20. 40 CFR Part 423 — Steam electric power generating point source category · eCFR as of 2026-10-05
  21. 40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05
  22. 40 CFR Part 425 — Leather tanning and finishing point source category · eCFR as of 2026-10-05
  23. 40 CFR Part 426 — Glass manufacturing point source category · eCFR as of 2026-10-05
  24. 40 CFR Part 427 — Asbestos manufacturing point source category · eCFR as of 2026-10-05
  25. 40 CFR Part 428 — Rubber manufacturing point source category · eCFR as of 2026-10-05
  26. 40 CFR Part 429 — Timber products processing point source category · eCFR as of 2026-10-05
  27. 40 CFR Part 430 — The pulp, paper, and paperboard point source category · eCFR as of 2026-10-05
  28. 40 CFR Part 432 — Meat and poultry products point source category · eCFR as of 2026-10-05
  29. 40 CFR Part 434 — Coal mining point source category BPT, BAT, BCT limitations and new source performance standards · eCFR as of 2026-10-05
  30. 40 CFR Part 435 — Oil and gas extraction point source category · eCFR as of 2026-10-05
  31. 40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05
  32. 40 CFR Part 438 — Metal products and machinery point source category · eCFR as of 2026-10-05
  33. 40 CFR Part 439 — Pharmaceutical manufacturing point source category · eCFR as of 2026-10-05
  34. 40 CFR Part 443 — Effluent limitations guidelines for existing sources and standards of performance and pretreatment… · eCFR as of 2026-10-05
  35. 40 CFR Part 444 — Waste combustors point source category · eCFR as of 2026-10-05
  36. 40 CFR Part 445 — Landfills point source category · eCFR as of 2026-10-05
  37. 40 CFR Part 446 — Paint formulating point source category · eCFR as of 2026-10-05
  38. 40 CFR Part 447 — Ink formulating point source category · eCFR as of 2026-10-05
  39. 40 CFR Part 449 — Airport deicing point source category · eCFR as of 2026-10-05
  40. 40 CFR Part 454 — Gum and wood chemicals manufacturing point source category · eCFR as of 2026-10-05
  41. 40 CFR Part 455 — Pesticide chemicals · eCFR as of 2026-10-05
  42. 40 CFR Part 457 — Explosives manufacturing point source category · eCFR as of 2026-10-05
  43. 40 CFR Part 458 — Carbon black manufacturing point source category · eCFR as of 2026-08-01
  44. 40 CFR Part 459 — Photographic point source category · eCFR as of 2026-10-05
  45. 40 CFR Part 460 — Hospital point source category · eCFR as of 2026-10-05
  46. 40 CFR Part 463 — Plastics molding and forming point source category · eCFR as of 2026-10-05
  47. 40 CFR Part 464 — Metal molding and casting point source category · eCFR as of 2026-10-05
  48. 40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05
  49. 40 CFR Part 467 — Aluminum forming point source category · eCFR as of 2026-10-05
  50. 40 CFR Part 469 — Electrical and electronic components point source category · eCFR as of 2026-10-05
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the nickel limits in Washington? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=nickel&place=US-WA; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI