Passage Data · Cited limits by place · Use it from your AI

Cadmium in Virginia (US-VA): 40 CFR Part 413 — Electroplating point source category

56 rows for cadmium in this instrument. Every instrument for cadmium in Virginia

United States (US): 56 rows

Effluent: 56 rows

40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05 · 56 limits
Every row: discharge to a sewer (pretreatment); existing sources (PSES)
ParameterValueStatisticApplies whenCite
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
Cd 1.2 .7
Cd.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd.7 mg/L—as aboveas above
Cd47 mg/sq m-Operationdaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.14 (PSES)
Cd 47 29
Cd29 mg/sq m-Operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart A—Electroplating of Common Metals Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
Cd 1.2 .7
Cd.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.24 (PSES)
Cd 1.2 .7
Cd.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd.7 mg/L—as aboveas above
Cd47 mg/sq m-Operationdaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.24 (PSES)
Cd 47 29
Cd29 mg/sq m-Operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart B—Electroplating of Precious Metals Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.24 (PSES)
Cd 1.2 .7
Cd.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.44 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd0.7 mg/L—as aboveas above
Cd47 mg/sq m-operationdaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)
40 CFR 413.44 (PSES)
Cd 47 29
Cd29 mg/sq m-operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart D—Anodizing Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.44 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart E—Coatings Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart E—Coatings Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.54 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart E—Coatings Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd0.7 mg/L—as aboveas above
Cd47 mg/sq m-operationdaily maximumthe discharge is of the Subpart E—Coatings Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)
40 CFR 413.54 (PSES)
Cd 47 29
Cd29 mg/sq m-operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart E—Coatings Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.54 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart F—Chemical Etching and Milling Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart F—Chemical Etching and Milling Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.64 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart F—Chemical Etching and Milling Subcategory
(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd0.7 mg/L—as aboveas above
Cd47 mg/sq m-operationdaily maximumthe discharge is of the Subpart F—Chemical Etching and Milling Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)
40 CFR 413.64 (PSES)
Cd 47 29
Cd29 mg/sq m-operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart F—Chemical Etching and Milling Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.64 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart G—Electroless Plating Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart G—Electroless Plating Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.74 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart G—Electroless Plating Subcategory
(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd0.7 mg/L—as aboveas above
Cd47 mg/sq m-operationdaily maximumthe discharge is of the Subpart G—Electroless Plating Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)
40 CFR 413.74 (PSES)
Cd 47 29
Cd29 mg/sq m-operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart G—Electroless Plating Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.74 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart H—Printed Circuit Board Subcategory
(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart H—Printed Circuit Board Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.84 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart H—Printed Circuit Board Subcategory
(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Cd0.7 mg/L—as aboveas above
Cd107 mg/sq m-operationdaily maximumthe discharge is of the Subpart H—Printed Circuit Board Subcategory
(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)
40 CFR 413.84 (PSES)
Cd 107 65
Cd65 mg/sq m-operation—as aboveas above
Cd1.2 mg/Ldaily maximumthe discharge is of the Subpart H—Printed Circuit Board Subcategory
(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…
table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
40 CFR 413.84 (PSES)
Cd 1.2 0.7
Cd0.7 mg/L—as aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.