Passage Data · Cited limits by place
1,790 numeric limits and guidelines for ph held for Utah and the place above it, from 49 instruments, each cited to its instrument, edition, section or page and quoted text. The register was built from 247 instruments. Everything held for Utah
The address to add: https://passage-data.com/mcp
https://passage-data.com/mcp.claude mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the ph limits in Utah? Cite each one.”
For programs: this page as JSON at /api/v1/limits?parameter=ph&place=US-UT; the same at https://passage-data.com/mcp, a remote MCP server (tool find_limits). llms.txt · OpenAPI
| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| pH | 6.5-9.0 | pH units | surface water · guideline | receiving water: freshwater water with the beneficial use Class 3A: cold water species of game fish and other cold water aquatic life (R317-2-6; uses by water in R317-2-13) | Utah Admin. Code R317-2-14 numeric criteria Utah Admin. Code R317-2-14 Table 2.14.2 · p. 39 pH (Range)(2a) 6.5-9.0 6.5-9.0 6.5-9.0 6.5-9.0 | |
| pH | 6.5-9.0 | pH units | surface water · guideline | receiving water: freshwater water with the beneficial use Class 3B: warm water species of game fish and other warm water aquatic life (R317-2-6; uses by water in R317-2-13) | Utah Admin. Code R317-2-14 numeric criteria Utah Admin. Code R317-2-14 Table 2.14.2 · p. 39 pH (Range)(2a) 6.5-9.0 6.5-9.0 6.5-9.0 6.5-9.0 | |
| pH | 6.5-9.0 | pH units | surface water · guideline | receiving water: freshwater water with the beneficial use Class 3C: nongame fish and other aquatic life (R317-2-6; uses by water in R317-2-13) | Utah Admin. Code R317-2-14 numeric criteria Utah Admin. Code R317-2-14 Table 2.14.2 · p. 39 pH (Range)(2a) 6.5-9.0 6.5-9.0 6.5-9.0 6.5-9.0 | |
| pH | 6.5-9.0 | pH units | surface water · guideline | receiving water: freshwater water with the beneficial use Class 3D: waterfowl, shore birds and other water-oriented wildlife (R317-2-6; uses by water in R317-2-13) | Utah Admin. Code R317-2-14 numeric criteria Utah Admin. Code R317-2-14 Table 2.14.2 · p. 39 pH (Range)(2a) 6.5-9.0 6.5-9.0 6.5-9.0 6.5-9.0 |
| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| pH | 6.0 to 9.0 | pH units | effluent · limit | stream: sanitary route: direct a publicly owned treatment works (POTW): the part sets the effluent quality attainable by secondary treatment, which NPDES permits for POTWs carry (40 CFR 133.100, 133.102) unless the POTW demonstrates that inorganic chemicals are not added as part of treatment and industrial contributions do not move the pH outside 6.0-9.0 (§ 133.102(c)) | 40 CFR Part 133 — Secondary Treatment Regulation 40 CFR 133.102 (secondary treatment) (c) pH. The effluent values for pH shall be maintained within the limits of 6.0 to 9.0 unless the publicly owned treatment works demonstrates that: (1) Inorganic chemicals are not added to the waste stream as part of the treatment process; and (2) contributions from industrial sources do not cause the pH of the effluent to be less than 6.0 or greater than 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart A—Receiving Stations Subcategory existing sources (BPT) (a) For receiving stations receiving more than 150,000 lb/day of milk equivalent (15,600 lb/day or more of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart A—Receiving Stations Subcategory existing sources (BPT) (b) For receiving stations receiving 150,000 lb/day or less of milk equivalent (under 15,600 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart A—Receiving Stations Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.15 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart B—Fluid Products Subcategory existing sources (BPT) (a) For fluid products plants receiving more than 250,000 lb/day of milk equivalent (more than 25,900 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart B—Fluid Products Subcategory existing sources (BPT) (b) For fluid products plants receiving 250,000 lb/day or less of milk equivalent (less than 25,900 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart B—Fluid Products Subcategory new sources (NSPS) | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.25 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart C—Cultured Products Subcategory existing sources (BPT) (a) For cultured products plants receiving more than 60,000 lb/day of milk equivalent (more than 6,200 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.32 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart C—Cultured Products Subcategory existing sources (BPT) (b) For cultured products plants receiving 60,000 lb/day or less of milk equivalent (less than 6,200 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.32 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart C—Cultured Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart D—Butter Subcategory existing sources (BPT) (a) For plants processing more than 175,000 lb/day of milk equivalent (more than 18,180 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart D—Butter Subcategory existing sources (BPT) (b) For plants processing 175,000 lb/day or less of milk equivalent (less than 18,180 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart D—Butter Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.45 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart E—Cottage Cheese and Cultured Cream Cheese Subcategory existing sources (BPT) (a) For plants processing more than 25,000 lb/day of milk equivalent (more than 2,600 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.52 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart E—Cottage Cheese and Cultured Cream Cheese Subcategory existing sources (BPT) (b) For plants processing 25,000 lb/day or less of milk equivalent (less than 2,600 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.52 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart E—Cottage Cheese and Cultured Cream Cheese Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.55 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart F—Natural and Processed Cheese Subcategory existing sources (BPT) (a) For plants processing more than 100,000 lb/day of milk equivalent (more than 10,390 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart F—Natural and Processed Cheese Subcategory existing sources (BPT) (b) For plants processing 100,000 lb/day or less of milk equivalent (less than 10,390 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart F—Natural and Processed Cheese Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart G—Fluid Mix for Ice Cream and Other Frozen Desserts Subcategory existing sources (BPT) (a) For plants with a dairy products input of more than 85,000 lb/day of milk equivalent (more than 8,830 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.72 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart G—Fluid Mix for Ice Cream and Other Frozen Desserts Subcategory existing sources (BPT) (b) For plants with a dairy products input of 85,000 lb/day or less of milk equivalent (less than 8.830 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.72 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart G—Fluid Mix for Ice Cream and Other Frozen Desserts Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.75 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart H—Ice Cream, Frozen Desserts, Novelties and Other Dairy Desserts Subcategory existing sources (BPT) (a) For plants with a dairy products input of more than 85,000 lb/day of milk equivalent (more than 8,830 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart H—Ice Cream, Frozen Desserts, Novelties and Other Dairy Desserts Subcategory existing sources (BPT) (b) For plants with a dairy products input of 85,000 lb/day or less of milk equivalent (less than 8,830 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart H—Ice Cream, Frozen Desserts, Novelties and Other Dairy Desserts Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.85 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart I—Condensed Milk Subcategory existing sources (BPT) (a) For plants condensing more than 100,000 lb/day of milk equivalent (more than 10,390 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart I—Condensed Milk Subcategory existing sources (BPT) (b) For plants condensing 100,000 lb/day or less of milk equivalent (less than 10,390 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart I—Condensed Milk Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.95 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart J—Dry Milk Subcategory existing sources (BPT) (a) For milk drying plants with an input equivalent to more than 145,000 lb/day of milk equivalent (more than 15,070 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.102 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart J—Dry Milk Subcategory existing sources (BPT) (b) For milk drying plants with an input equivalent to 145,000 lb/day or less of milk equivalent (less than 15,070 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.102 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart J—Dry Milk Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart. | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.105 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart K—Condensed Whey Subcategory existing sources (BPT) (a) For whey condensing plants with over 300,000 lb/day of fluid raw whey input (over 20,700 lb/day of solids or 14,160 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.112 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart K—Condensed Whey Subcategory existing sources (BPT) (b) For whey condensing plants with 300,000 lb/day or less of raw fluid whey input (less than 20,700 lb/day of solids or 14,160 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.112 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart K—Condensed Whey Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.115 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart L—Dry Whey Subcategory existing sources (BPT) (a) For whey drying plants with an input equivalent to more than 57,000 lb/day of 40 percent solids whey (22,800 lb/day of solids or 15,620 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.122 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart L—Dry Whey Subcategory existing sources (BPT) (b) For whey drying plants with an input equivalent to 57,000 lb/day or less of 40 percent solids whey (under 22,800 lb/day solids or 15,620 lb/day of BOD 5 input). | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.122 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 405 the discharge is of the Subpart L—Dry Whey Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 405 — PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY 40 CFR 405.125 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart A—Corn Wet Milling Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart A—Corn Wet Milling Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.15 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart A—Corn Wet Milling Subcategory existing sources (BCT) (a) Subject to the provisions in paragraph (b) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.17 (BCT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart B—Corn Dry Milling Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart B—Corn Dry Milling Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this part: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.25 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart D—Bulgur Wheat Flour Milling Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart D—Bulgur Wheat Flour Milling Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.45 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart F—Parboiled Rice Processing Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart F—Parboiled Rice Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart I—Ready-to-Eat Cereal Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart I—Ready-to-Eat Cereal Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.95 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart J—Wheat Starch and Gluten Subcategory existing sources (BPT) | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.102 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 406 the discharge is of the Subpart J—Wheat Starch and Gluten Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 406 — PART 406—GRAIN MILLS POINT SOURCE CATEGORY 40 CFR 406.105 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart A—Apple Juice Subcategory existing sources (BPT) | 40 CFR Part 407 40 CFR 407.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart A—Apple Juice Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 407 40 CFR 407.15 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart B—Apple Products Subcategory existing sources (BPT) | 40 CFR Part 407 40 CFR 407.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart B—Apple Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 407 40 CFR 407.25 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart C—Citrus Products Subcategory existing sources (BPT) | 40 CFR Part 407 40 CFR 407.32 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart C—Citrus Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 407 40 CFR 407.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart D—Frozen Potato Products Subcategory existing sources (BPT) | 40 CFR Part 407 40 CFR 407.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart D—Frozen Potato Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 407 40 CFR 407.45 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart E—Dehydrated Potato Products Subcategory existing sources (BPT) | 40 CFR Part 407 40 CFR 407.52 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart E—Dehydrated Potato Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 407 40 CFR 407.55 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.5 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart F—Canned and Preserved Fruits Subcategory existing sources (BPT) (c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. | 40 CFR Part 407 40 CFR 407.62 (BPT) pH At all times within the range 6.0 to 9.5. | |
| pH | 6.0 to 9.5 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart G—Canned and Preserved Vegetables Subcategory existing sources (BPT) (c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. The effluent limitations do not apply to single-commodity 100 percent canned corn processing plants of all sizes, an… | 40 CFR Part 407 40 CFR 407.72 (BPT) pH At all times within the range 6.0 to 9.5. | |
| pH | 6.0 to 9.5 | pH units | effluent · limit | route: direct cites: 40 CFR 407 the discharge is of the Subpart H—Canned and Miscellaneous Specialties Subcategory existing sources (BPT) (c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. | 40 CFR Part 407 40 CFR 407.82 (BPT) pH At all times within the range 6.0 to 9.5 exceed 10 mg/l. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart A—Farm-Raised Catfish Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart A—Farm-Raised Catfish Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.15 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart B—Conventional Blue Crab Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart B—Conventional Blue Crab Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.25 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart C—Mechanized Blue Crab Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.32 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart C—Mechanized Blue Crab Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart D—Non-Remote Alaskan Crab Meat Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart D—Non-Remote Alaskan Crab Meat Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.45 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart F—Non-Remote Alaskan Whole Crab and Crab Section Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart F—Non-Remote Alaskan Whole Crab and Crab Section Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart H—Dungeness and Tanner Crab Processing in the Contiguous States Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart H—Dungeness and Tanner Crab Processing in the Contiguous States Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.85 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart I—Non-Remote Alaskan Shrimp Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart I—Non-Remote Alaskan Shrimp Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.95 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart K—Northern Shrimp Processing in the Contiguous States Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.112 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart K—Northern Shrimp Processing in the Contiguous States Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.115 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart L—Southern Non-Breaded Shrimp Processing in the Contiguous States Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.122 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart L—Southern Non-Breaded Shrimp Processing in the Contiguous States Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.125 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart M—Breaded Shrimp Processing in the Contiguous States Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.132 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart M—Breaded Shrimp Processing in the Contiguous States Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.135 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart N—Tuna Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.142 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart N—Tuna Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.145 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart O—Fish Meal Processing Subcategory existing sources (BPT) (a) Any menhaden or anchovy fish meal reduction facility which utilizes a solubles plant to process stick water or bail water shall meet the following limitations. | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.152 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart O—Fish Meal Processing Subcategory existing sources (BPT) (b) Any menhaden or anchovy fish meal reduction facility not covered under § 408.152(a) shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.152 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart O—Fish Meal Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.155 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart P—Alaskan Hand-Butchered Salmon Processing Subcategory existing sources (BPT) (a) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.162 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart P—Alaskan Hand-Butchered Salmon Processing Subcategory new sources (NSPS) (1) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.165 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Q—Alaskan Mechanized Salmon Processing Subcategory existing sources (BPT) (a) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.172 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Q—Alaskan Mechanized Salmon Processing Subcategory new sources (NSPS) (1) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.175 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart R—West Coast Hand-Butchered Salmon Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.182 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart R—West Coast Hand-Butchered Salmon Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.185 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart S—West Coast Mechanized Salmon Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.192 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart S—West Coast Mechanized Salmon Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.195 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart T—Alaskan Bottom Fish Processing Subcategory existing sources (BPT) (a) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.202 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart T—Alaskan Bottom Fish Processing Subcategory new sources (NSPS) (1) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.205 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart U—Non-Alaskan Conventional Bottom Fish Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.212 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart U—Non-Alaskan Conventional Bottom Fish Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.215 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart V—Non-Alaskan Mechanized Bottom Fish Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.222 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart V—Non-Alaskan Mechanized Bottom Fish Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.225 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart W—Hand-Shucked Clam Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.232 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart W—Hand-Shucked Clam Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.235 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart X—Mechanized Clam Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.242 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart X—Mechanized Clam Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.245 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.252 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.255 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory existing sources (BCT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.257 (BCT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.262 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.265 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory existing sources (BCT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.267 (BCT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AA—Steamed and Canned Oyster Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.272 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AA—Steamed and Canned Oyster Processing Subcategory new sources (NSPS) Except for those steamed and canned oyster processing facilities which utilize air flotation treatment systems to meet the shrimp processing standards of performance for new sources under § 408.115, § 408.125, or § 408.135 and for which standards of performance should be derived on a case-by-case basis, the following standards of performance establish the quantity or quality of pollutants or po… | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.275 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AB—Sardine Processing Subcategory existing sources (BPT) (a) Any sardine processing facility which utilizes dry transportation systems from the fish storage area to the fish processing area shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.282 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AB—Sardine Processing Subcategory existing sources (BPT) (b) Any sardine processing facility not covered under § 408.282(a) shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.282 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AB—Sardine Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.285 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AC—Alaskan Scallop Processing Subcategory existing sources (BPT) (a) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.292 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AC—Alaskan Scallop Processing Subcategory new sources (NSPS) (1) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.295 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AD—Non-Alaskan Scallop Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.302 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AD—Non-Alaskan Scallop Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.305 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AD—Non-Alaskan Scallop Processing Subcategory existing sources (BCT) column: Efflluent limitations | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.307 (BCT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AE—Alaskan Herring Fillet Processing Subcategory existing sources (BPT) (a) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.312 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AE—Alaskan Herring Fillet Processing Subcategory new sources (NSPS) (1) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.315 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.322 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.325 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AG—Abalone Processing Subcategory existing sources (BPT) | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.332 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AG—Abalone Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.335 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 408 the discharge is of the Subpart AG—Abalone Processing Subcategory existing sources (BCT) column: Efflluent limitations | 40 CFR Part 408 — PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY 40 CFR 408.337 (BCT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart A—Beet Sugar Processing Subcategory existing sources (BPT) (a) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results from barometric condensing operations only. | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart A—Beet Sugar Processing Subcategory existing sources (BPT) (b) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results, in whole or in part, from barometric condensing operations and any other beet sugar processing operation. | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart B—Crystalline Cane Sugar Refining Subcategory existing sources (BPT) (a) Any crystalline cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributed to the barometric condenser cooling water to that amount of BOD 5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to t… | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart B—Crystalline Cane Sugar Refining Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.25 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart C—Liquid Cane Sugar Refining Subcategory existing sources (BPT) (a) Any liquid cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributed to the barometric condenser cooling water to that amount of BOD 5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to the tr… | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.32 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart C—Liquid Cane Sugar Refining Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart D—Louisiana Raw Cane Sugar Processing Subcategory existing sources (BPT) (a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributable to the barometric condenser cooling water to that amount of BOD 5 attributable to the treated process waste water. The TSS limitation is that amount of TSS… | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart D—Louisiana Raw Cane Sugar Processing Subcategory existing sources (BPT) (b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributable to the barometric condenser cooling water to that amount of BOD 5 attributable to the treated process waste water. The TSS limit… column: Effluent limitations, the total of the daily values for the entire discharge period shall not exceed— | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.42 (BPT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart H—Puerto Rican Raw Cane Sugar Processing Subcategory existing sources (BPT) (a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributable to the barometric condenser cooling water to that amount of BOD 5 attributable to the treated process waste water. The TSS limitation is that amount of TSS… | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 409 the discharge is of the Subpart H—Puerto Rican Raw Cane Sugar Processing Subcategory existing sources (BPT) (b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributable to the barometric condenser cooling water to that amount of BOD 5 attributable to the treated process waste water. The TSS limit… column: Effluent limitations, the total of the daily values for the entire discharge period shall not exceed— | 40 CFR Part 409 — PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY 40 CFR 409.82 (BPT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart A—Wool Scouring Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart A—Wool Scouring Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.15 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart B—Wool Finishing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart B—Wool Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.25 (NSPS) pH ( 1 ) ( 1 ) | |
| ph | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart C—Low Water Use Processing Subcategory existing sources (BPT) table: General Processing | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.32 (BPT) ph ( 1 ) ( 1 ) | |
| ph | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart C—Low Water Use Processing Subcategory existing sources (BPT) table: Water Jet Weaving | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.32 (BPT) ph ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart C—Low Water Use Processing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: General Processing | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart C—Low Water Use Processing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Water Jet Weaving | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.35 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart D—Woven Fabric Finishing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart D—Woven Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Simple Manufacturing Operations | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.45 (NSPS) pH 1 ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart D—Woven Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Complex Manufacturing Operations | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.45 (NSPS) pH 1 ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart D—Woven Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Desizing | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.45 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart E—Knit Fabric Finishing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.52 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart E—Knit Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Simple Manufacturing Operations | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.55 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart E—Knit Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Complex Manufacturing Operations | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.55 (NSPS) pH ( 1 −) ( 1 −) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart E—Knit Fabric Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Hosiery Products | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.55 (NSPS) pH ( 1 −) ( 1 −) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart F—Carpet Finishing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart F—Carpet Finishing Subcategory new sources (NSPS) Any new source subject to this subject must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart G—Stock and Yarn Finishing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.72 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart G—Stock and Yarn Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.75 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart H—Nonwoven Manufacturing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart H—Nonwoven Manufacturing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.85 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart I—Felted Fabric Processing Subcategory existing sources (BPT) | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 410 the discharge is of the Subpart I—Felted Fabric Processing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR Part 410 — PART 410—TEXTILE MILLS POINT SOURCE CATEGORY 40 CFR 410.95 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart A—Nonleaching Subcategory existing sources (BPT) | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.12 (BPT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart A—Nonleaching Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.15 (NSPS) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart A—Nonleaching Subcategory existing sources (BCT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology. | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.17 (BCT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart B—Leaching Subcategory existing sources (BPT) | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.22 (BPT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart B—Leaching Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.25 (NSPS) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory existing sources (BPT) | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.32 (BPT) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory new sources (NSPS) (a) Subject to the provisions of paragraph (b) of this section the following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.35 (NSPS) pH Within the range 6.0 to 9.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 411 the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory existing sources (BCT) (a) Subject to the provisions of paragraph (b) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology. | 40 CFR Part 411 — PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 411.37 (BCT) pH Within the range 6.0 to 9.0. | |
| pH | 1 | mg/L | daily maximum | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart A—Electroplating of Common Metals Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.14 (PSES) pH 1 1 |
| pH | 1 | mg/L | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart A—Electroplating of Common Metals Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.14 (PSES) pH 1 1 | |
| pH | 1 | mg/L | daily maximum | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.24 (PSES) pH 1 1 |
| pH | 1 | mg/L | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.24 (PSES) pH 1 1 | |
| pH | 7.5 to 10.000 | pH units | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart D—Anodizing Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.44 (PSES) pH ( 1 ) ( 1 ) | |
| pH | 7.5 to 10.0 | pH units | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart E—Coatings Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.54 (PSES) pH ( 1 ) ( 1 ) | |
| pH | 7.5 to 10.0 | pH units | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart F—Chemical Etching and Milling Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.64 (PSES) pH ( 1 ) ( 1 ) | |
| pH | 7.5 to 10.00 | pH units | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart G—Electroless Plating Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.74 (PSES) pH ( 1 ) ( 1 ) | |
| pH | 7.5 to 10.0 | pH units | effluent · limit | route: sewer cites: 40 CFR 413 the discharge is of the Subpart H—Printed Circuit Board Subcategory existing sources (PSES) (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY 40 CFR 413.84 (PSES) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart B—Rayon Fibers existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.21 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart B—Rayon Fibers new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.24 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart C—Other Fibers existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.31 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart C—Other Fibers new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.34 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart D—Thermoplastic Resins existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.41 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart D—Thermoplastic Resins new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.44 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart E—Thermosetting Resins existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.51 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart E—Thermosetting Resins new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.54 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart F—Commodity Organic Chemicals existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.61 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart F—Commodity Organic Chemicals new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.64 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart G—Bulk Organic Chemicals existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.71 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart G—Bulk Organic Chemicals new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.74 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart H—Specialty Organic Chemicals existing sources (BPT) | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.81 (BPT) pH ( 2 ) ( 2 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i route: direct cites: 40 CFR 414 the discharge is of the Subpart H—Specialty Organic Chemicals new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS 40 CFR 414.84 (NSPS) pH ( 2 ) ( 2 ) | |
| pH | 5.0 to 10.0 | pH units | effluent · limit | route: sewer cites: 40 CFR 415 the discharge is of the Subpart A—Aluminum Chloride Production Subcategory existing sources (PSES) table: Subpart A—Aluminum Chloride | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.14 (PSES) pH Within the range 5.0 to 10.0. | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart B—Aluminum Sulfate Production Subcategory existing sources (BPT) (d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements: table: Subpart B—Aluminum Sulfate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.22 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart D—Calcium Chloride Production Subcategory existing sources (BPT) table: Subpart D—Calcium Chloride | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.42 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart E—Calcium Oxide Production Subcategory existing sources (BPT) (d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements: table: Subpart E—Calcium Oxide | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.52 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production) existing sources (BPT) table: Subpart F—Chlor-Alkali Mercury Cells | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production) existing sources (BPT) table: Subpart F—Chlor-Alkali Diaphragm Cells | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.62 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production) new sources (NSPS) (a) Any new source subject to this subpart and using the mercury cell process must achieve the following new source performance standards (NSPS): table: Subpart F—Chlor-Alkali-Mercury Cells | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production) new sources (NSPS) (b) Any new source subject to this subpart and using the diaphragm cell process must achieve the following new source performance standards (NSPS): table: Subpart F—Chlor-Alkali-Diaphragm Cells | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.65 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory existing sources (BPT) table: Subpart H—Hydrofluoric Acid | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.82 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart H—Hydrofluoric Acid | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.85 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart I—Hydrogen Peroxide Production Subcategory existing sources (BPT) table: Subpart I—Hydrogen Peroxide Organic Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.92 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart I—Hydrogen Peroxide Production Subcategory existing sources (BPT) table: Subpart I—Hydrogen Peroxide Electrolyte Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.92 (BPT) pH ( 1 ) ( 1 ) | |
| ph | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart M—Potassium Sulfate Production Subcategory existing sources (BPT) (d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements: table: Subpart M—Potassium Sulfate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.132 (BPT) ph ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart P—Sodium Chloride Production Subcategory existing sources (BPT) table: Subpart P—Sodium Chloride Brine Mining Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.162 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory existing sources (BPT) table: Subpart Q—Sodium Dichromate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.172 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart T—Sodium Sulfite Production Subcategory existing sources (BPT) table: Subpart T—Sodium Sulfite | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.202 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart T—Sodium Sulfite Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart T—Sodium Sulfite | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.205 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory existing sources (BPT) table: Subpart V—Titanium Dioxide-Sulfate Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.222 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory existing sources (BPT) table: Subpart V—Titanium Dioxide-Chloride Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.222 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory existing sources (BPT) table: Subpart V—Titanium Dioxide-Chloride-Ilmenite Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.222 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory new sources (NSPS) (a) Any new source subject to this subpart producing titanium dioxide by the sulfate process must achieve the following new source performance standards (NSPS): table: Subpart V—Titanium Dioxide-Sulfate Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.225 (NSPS) pH ( 1 ) ( 1 ) | |
| ph | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory new sources (NSPS) (b) Any new source subject to this subpart producing titanium dioxide by the chloride process must achieve the following new source performance standards (NSPS): table: Subpart V—Titanium Dioxide-Chloride Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.225 (NSPS) ph ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart V—Titanium Dioxide Production Subcategory new sources (NSPS) (c) Any new source subject to this subpart producing titanium dioxide by the simultaneous beneficiation-chlorination (chloride-ilmenite) process must achieve the following new source performance standards (NSPS): table: Subpart V—Titanium Dioxide-Chloride-Ilmenite Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.225 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory existing sources (BPT) table: Subpart W—Aluminum Fluoride column: Pollutant or pollutant property | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.232 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart X—Ammonium Chloride Production Subcategory existing sources (BPT) table: Subpart X—Ammonium Chloride Solvay Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.242 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AB—Boric Acid Production Subcategory existing sources (BPT) table: Subpart AB—Boric Acid Mined Borax Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.282 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AD—Calcium Carbonate Production Subcategory existing sources (BPT) table: Subpart AD—Calcium Carbonate Milk of Lime Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.302 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AD—Calcium Carbonate Production Subcategory existing sources (BPT) table: Subpart AD—Calcium Carbonate Solvay Recovery Process | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.302 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AG—Carbon Monoxide and By-Product Hydrogen Production Subcategory existing sources (BPT) table: Subpart AG—Carbon Monoxide | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.332 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AH—Chrome Pigments Production Subcategory existing sources (BPT) table: Subpart AH—Chrome Pigments | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.342 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AJ—Copper Salts Production Subcategory existing sources (BPT) table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.362 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AJ—Copper Salts Production Subcategory existing sources (BPT) table: Subpart AJ—Copper Carbonate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.362 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 10.5 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AP—Hydrogen Cyanide Production Subcategory existing sources (BPT) table: Subpart AP—Hydrogen Cyanide | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.422 (BPT) pH ( 1 ) ( 1 ) | |
| Ph | 6.0 to 10.5 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AP—Hydrogen Cyanide Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart AP—Hydrogen Cyanide | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.425 (NSPS) Ph ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AU—Nickel Salts Production Subcategory existing sources (BPT) table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.472 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AU—Nickel Salts Production Subcategory existing sources (BPT) table: Subpart AU—Nickel Carbonate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.472 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AU—Nickel Salts Production Subcategory new sources (NSPS) (a) Any new source subject to this subpart and producing nickel sulfate, nickel chloride, nickel fluorobate or nickel nitrate must achieve the following new source performance standards (NSPS): table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, and Nickel Fluoborate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.475 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AU—Nickel Salts Production Subcategory new sources (NSPS) (b) Any new source subject to this subpart and producing nickel carbonate must achieve the following new source performance standards (NSPS): table: Subpart AU—Nickel Carbonate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.475 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AW—Oxygen and Nitrogen Production Subcategory existing sources (BPT) table: Subpart AW—Oxygen and Nitrogen | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.492 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart AY—Potassium Iodide Production Subcategory existing sources (BPT) table: Subpart AY—Potassium Iodide | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.512 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BA—Silver Nitrate Production Subcategory existing sources (BPT) table: Subpart BA—Silver Nitrate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.532 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BB—Sodium Bisulfite Production Subcategory existing sources (BPT) table: Subpart BB—Sodium Bisulfite | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.542 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory existing sources (BPT) table: Subpart BL—Cadmium Pigments | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.642 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory existing sources (BPT) table: Subpart BL—Cadmium Salts | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.642 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BM—Cobalt Salts Production Subcategory existing sources (BPT) table: Subpart BM—Cobalt Salts | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.652 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory existing sources (BPT) table: Subpart BN—Sodium Chlorate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.662 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart BN—Sodium Chlorate | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.665 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 10.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BO—Zinc Chloride Production Subcategory existing sources (BPT) table: Subpart BO—Zinc Chloride | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.672 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 10.0 | pH units | effluent · limit | route: direct cites: 40 CFR 415 the discharge is of the Subpart BO—Zinc Chloride Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart BO—Zinc Chloride | 40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY 40 CFR 415.675 (NSPS) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 417 the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory existing sources (BPT) | 40 CFR Part 417 — PART 417—SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 417.12 (BPT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 417 the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR Part 417 — PART 417—SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 417.13 (BAT) pH ( 1 ) ( 1 ) | |
| pH | 6.0 to 9.0 | pH units | effluent · limit | route: direct cites: 40 CFR 417 the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR Part 417 — PART 417—SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY 40 CFR 417.15 (NSPS) pH ( 1 ) ( 1 ) |
This page shows the first 250 of 1,790 rows, Utah's own first. All of them, as JSON 200 at a time: 1–200 · 201–400 · 401–600 · 601–800 · 801–1,000 · 1,001–1,200 · 1,201–1,400 · 1,401–1,600 · 1,601–1,790
Every instrument we hold for Utah (US-UT) and the place above it, United States (US): 67 instruments, for every parameter name matching “ph”: ph, ph wert, ph change ph, siloxanes and silicones me ph, aluminum dissolved ph 6 5 9 0 only, aluminum dissolved ph 6 5 to 9 0 only, parathion pentachlorophenol e 1 005 ph 4 869, polysiloxanes di me di ph hydroxy terminated, 1 4 benzenediamine n n mixed ph and tolyl derivs, siloxanes and silicones di me di ph hydroxy terminated, siloxanes and silicones di ph me ph polymers with me ph silsesquioxanes, siloxanes and silicones di me me methoxy methoxy ph polymers with me ph silsesquioxanes, and 2 more (in the JSON).
d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf — 433 rows here2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea — 268 rows here15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898 — 143 rows here940c0585603141d76af0790879f64c667489809aac317d090485198f492a1311 — 111 rows here6ee241b7ee9a78250fccd4d4134366c8ccc74eceba4512675bc5db8a5be24cc5 — 83 rows here4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925 — 76 rows here4b5bd5a797a31a077d5a797de292aab3ed4938bf350995c3877c393d3c1f8428 — 69 rows here39a50407f4cd89036e245861437f7961e58a8451efaa9fd6330ff45d381fa205 — 66 rows heree9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50 — 52 rows hereebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23 — 49 rows hereaa9ac14c0ef8e5cffe6bfb5a5368ab853aa9128404ac004a3de7bc0bab0c24bd — 36 rows hereaea3b68c1fc9aac4ea3fa56240df79cf606e97c278fd0b499c3ec190dad2ee9a — 36 rows here3a0399ddea806eb34f0fe9b3c15efa97679757f340a125b4af5fdc234a93fe6c — 33 rows herecb5058a08c9472074411dfb00b10ae90efb4763be56c41b6c33d5fec477a555b — 30 rows here3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849 — 28 rows here02c53988595c9f2911727f635f59f6a2af0c1d50ce06550c150a706321a505b3 — 24 rows here9984c22aee31f14ac6cc89b6895db16ce8ed6cdc39abf66752529e44a86fda45 — 22 rows herea824cc1c96559e03e9d0013c6dc961092352baafce6b5daec6be1d3c9ef96c4f — 21 rows here5b10885a56878a0a10277b8fdf945441e570a9316098995bb3f948e5bc5a52d9 — 15 rows here8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608 — 14 rows here28dbdea077be653555fa562c999b78c741237e57d5b8efc8606d183ce33279da — 13 rows here56de9012822853c75f8513babf1c1440ff957ff2145a12ec8ef5c1906da02f2d — 13 rows here59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19 — 13 rows here2aa1dbe8158371fa4360d0df2412ad8b47c124aab4173316b854dc9c06d9161a — 12 rows here8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01 — 11 rows here69910d7277f8067273b796c1905c6283621bc7c72723b388bab9b5c8f7983742 — 10 rows hereb9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed — 10 rows here699f842280ca1f65a56712a21ad9906bb9d709f20624757e72df02c7f695e73e — 10 rows here9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9 — 9 rows here4f4bb5077485ea6f8a27e678219c7400c18be7ca7824e5b21d1996399098cbc4 — 9 rows here14a34390b41a1060c6d5d7ede5e6018f118680d1cb54643b81fa9b50abea37c4 — 8 rows here8ffc3a5ae0e6c7d8e929b9201225a003c95d5c0e6a73ed549ae0ef4bb94b22ed — 8 rows here817c320835fb2f9cbb5e6218efb2f5cdcb0b0527933ae87d5a3976f0981127fd — 8 rows here4fcd842aa8d4463c015d5dc67a32412a7c554ad425715bb2375e64800bf4e7bd — 8 rows here83f54e1a9420fdb3abe9a4e4e8edd2060bbc0c5e0067824488d3f0f1cc50d328 — 7 rows here4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b — 7 rows hereca4f7d499465d74e9f9e97bbad32419b9e4d71c107bd17c21ec9348b86c19167 — 5 rows hereecd9919716fba76ef049e55c942f1387f9a8ec133cd140000105b0554af46a38 — 4 rows here881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda — 3 rows here0d9785d9dc37e256a6ea799566e33681f123b092975ccaaa01967665080b1598 — 2 rows here5903548fcfa58a4b6152d41cd1399b4c82e3684e69d5ea20a0fb89c1b71e4329 — 2 rows herebe6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec — 2 rows here9f178f66686e289aea4d4961eee13479c15774e48d25aea14710655d2aeb18f7 — 1 row hereb8df51b8c9ab0f6d765b07cb267f1aead5f9a257b5d9d914fb34511c1433a9bd — 1 row here36066b7d5702811c70e1498b6ff9647599f1a883a18bd95449abc5900832e375 — 1 row here465264d203dabbec52b8a9e5afc03c9b9140c4f1758d0f5cf422a0df03d3cce3 — 1 row heree78d4825199d5ba2cf468f744603f403b7dbddbe3321955e6a0b1e344de50d7f — 1 row herea0229d5a613672b46a000c5b9925dd3a23c3e05914bb020b7f739c69cecbb5fe — 1 row herea98e8b66948f546c71e119055eff012e6380857a255ec216a4247b658bcf040d — 1 row here2b162dead6acf77f69bd8a2a79a6195c30a6f7a6c82e29ec4754657603f1202d — no row here60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64 — no row here3b1a8b869cb040029bdcb18f0ff232995cfc9774f16112f5700bb1f5cb31daa4 — no row heree30d763aa2bf49914b8b02364329ed662c0af2bc1ac6ee13233ee65c1499a94e — no row heree485b5e90afd26961e2964355f78ce1d1a1781ac67e588a9f2ea6fd1ad913db2 — no row here23be7bb993614d9248cff594a196b782587671393fc7b4f445eab69876b224d8 — no row here109ea8c5ee22a37622c2aa91dd21d79e528a5f9f3e9d01ecc8dc18c25b6afd9e — no row here9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded — no row hereb5d02b5c87984639aaff6e500a6930c9e7b478cec825c013f26c72f715e32a0e — no row here07ce62c90f736e9aacb3b93854b6861d2d14ec3c7ed85146da489eb46ca5ebca — no row here6abcaec659f7bd98f5861813fc76e8a2f027753ba5488ec0da9540b3dff013a2 — no row here904434c6e85600060669580acf042d53f5e711e3313e8aef038d9c60b244a740 — no row here857e290109cd8028b70b239ab2b16e9c5d068a71e557a7c419ebba4dee2c40b4 — no row herec69109252c9521cd31b45755731369a860bb1282c273dea5fd6903836effa7c7 — no row herebd534eb2d8af38e141e1cd6236134a638298fbf14791b30279eeb47d815d7767 — no row here0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7 — no row here0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7 — no row hereRead from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.