Passage Data · Cited limits by place · Use it from your AI

Chromium (total) in Utah (US-UT): 40 CFR Part 424 — Ferroalloy manufacturing point source category

34 rows for chromium (total) in this instrument. Every instrument for chromium (total) in Utah

United States (US): 34 rows

Effluent: 34 rows

40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05 · 34 limits
Every row: discharge to surface water
ParameterValueStatisticApplies whenCite
Chromium0.106 kg/kkg of productdaily maximumthe discharge is of the Subpart G—Electrolytic Chromium Subcategory
existing sources (BPT)
40 CFR 424.72 (BPT)
Chromium 0.106 0.053
Chromium0.053 kg/kkg of productmonthly averageas aboveas above
Chromium.053 kg/kkg of productdaily maximumthe discharge is of the Subpart G—Electrolytic Chromium Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.73 (BAT)
Chromium .053 .027
Chromium.027 kg/kkg of productmonthly averageas aboveas above
Chromium total.006 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.12 (BPT)
Chromium total .006 .0032
Chromium total.0032 kg/Mwhmonthly averageas aboveas above
Chromium total0.0008 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.13 (BAT)
Chromium total 0.0008 0.0004
Chromium total0.0004 kg/Mwhmonthly averageas aboveas above
Chromium total.0008 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.15 (NSPS)
Chromium total .0008 .0004
Chromium total.0004 kg/Mwhmonthly averageas aboveas above
Chromium total.008 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.22 (BPT)
Chromium total .008 .004
Chromium total.004 kg/Mwhmonthly averageas aboveas above
Chromium total0.001 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.23 (BAT)
Chromium total 0.001 0.0005
Chromium total0.0005 kg/Mwhmonthly averageas aboveas above
Chromium total.001 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.25 (NSPS)
Chromium total .001 .0005
Chromium total.0005 kg/Mwhmonthly averageas aboveas above
Chromium total0.053 kg/kkg processeddaily maximumthe discharge is of the Subpart C—Slag Processing Subcategory
existing sources (BPT)
40 CFR 424.32 (BPT)
Chromium total 0.053 0.026
Chromium total0.026 kg/kkg processedmonthly averageas aboveas above
Chromium total0.0054 kg/kkg processeddaily maximumthe discharge is of the Subpart C—Slag Processing Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.33 (BAT)
Chromium total 0.0054 0.0027
Chromium total0.0027 kg/kkg processedmonthly averageas aboveas above
Chromium total.0054 kg/kkg processeddaily maximumthe discharge is of the Subpart C—Slag Processing Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.35 (NSPS)
Chromium total .0054 .0027
Chromium total.0027 kg/kkg processedmonthly averageas aboveas above
Chromium VI.0006 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.12 (BPT)
Chromium VI .0006 .0003
Chromium VI.0003 kg/Mwhmonthly averageas aboveas above
Chromium VI.00008 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.13 (BAT)
Chromium VI .00008 .00004
Chromium VI.00004 kg/Mwhmonthly averageas aboveas above
Chromium VI.00008 kg/Mwhdaily maximumthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.15 (NSPS)
Chromium VI .00008 .00004
Chromium VI.00004 kg/Mwhmonthly averageas aboveas above
Chromium VI.0008 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.22 (BPT)
Chromium VI .0008 .0004
Chromium VI.0004 kg/Mwhmonthly averageas aboveas above
Chromium VI.0001 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
40 CFR 424.23 (BAT)
Chromium VI .0001 .00005
Chromium VI.00005 kg/Mwhmonthly averageas aboveas above
Chromium VI.0001 kg/Mwhdaily maximumthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.25 (NSPS)
Chromium VI .0001 .00005
Chromium VI.00005 kg/Mwhmonthly averageas aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.