Copper in South Carolina (US-SC): 40 CFR Part 415 — Inorganic chemicals manufacturing point source category

30 rows for copper in this instrument. Every instrument for copper in South Carolina

United States (US): 30 rows

Effluent: 30 rows

40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01 · 30 limits
ParameterValueStatisticApplies whenCite
Copper (T)0.018 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (BPT)
table: Subpart F—Chlor-Alkali Diaphragm Cells
40 CFR 415.62 (BPT)
Copper (T) 0.018 0.0070
Copper (T)0.0070 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Copper (T)0.012 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (BAT)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.63 (BAT)
Copper (T) 0.012 0.0049
Copper (T)0.0049 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Copper (T)2.1 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
existing sources (PSES)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.64 (PSES)
Copper (T) 2.1 0.80
Copper (T)0.80 mg/Lmonthly averageas aboveas above
Copper (T)0.0030 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart AJ—Copper Salts Production Subcategory
existing sources (BPT)
table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate
40 CFR 415.362 (BPT)
Copper (T) 0.0030 0.0010
Copper (T)0.0010 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Copper (T)0.19 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart AJ—Copper Salts Production Subcategory
existing sources (BPT)
table: Subpart AJ—Copper Carbonate
40 CFR 415.362 (BPT)
Copper (T) 0.19 0.064
Copper (T)0.064 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Copper(T)3.2 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart AJ—Copper Salts Production Subcategory
existing sources (PSES)
table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate
40 CFR 415.364 (PSES)
Copper(T) 3.2 1.1
Copper(T)1.1 mg/Lmonthly averageas aboveas above
Copper (T)3.2 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart AJ—Copper Salts Production Subcategory
existing sources (PSES)
table: Subpart AJ—Copper Carbonate
40 CFR 415.364 (PSES)
Copper (T) 3.2 1.1
Copper (T)1.1 mg/Lmonthly averageas aboveas above
Copper (T)1.0 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart AL—Ferric Chloride Production Subcategory
existing sources (PSES)
table: Subpart AL—Ferric Chloride
40 CFR 415.384 (PSES)
Copper (T) 1.0 0.50
Copper (T)0.50 mg/Lmonthly averageas aboveas above
Copper (T)0.00074 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
existing sources (BAT)
table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate
40 CFR 415.473 (BAT)
Copper (T) 0.00074 0.00024
Copper (T)0.00024 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Copper (T)0.13 Kg/kkg (or pounds per/1,000 lb) or productdaily maximumdischarge to surface water
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
existing sources (BAT)
table: Subpart AU—Nickel Carbonate
40 CFR 415.473 (BAT)
Copper (T) 0.13 0.042
Copper (T)0.042 Kg/kkg (or pounds per/1,000 lb) or productmonthly averageas aboveas above
Copper(T)1.1 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
existing sources (PSES)
table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate
40 CFR 415.474 (PSES)
Copper(T) 1.1 0.36
Copper(T)0.36 mg/Lmonthly averageas aboveas above
Copper(T)1.1 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
existing sources (PSES)
table: Subpart AU—Nickel Carbonate
as above
Copper(T)0.36 mg/Lmonthly averageas aboveas above
Copper0.00074 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart and producing nickel sulfate, nickel chloride, nickel fluorobate or nickel nitrate must achieve the following new source performance standards (NSPS):
table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, and Nickel Fluoborate
40 CFR 415.475 (NSPS)
Copper 0.00074 0.00024
Copper0.00024 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Copper0.13 Kg/kkg (or pounds per/1,000 lb) or productdaily maximumdischarge to surface water
the discharge is of the Subpart AU—Nickel Salts Production Subcategory
new sources (NSPS)
(b) Any new source subject to this subpart and producing nickel carbonate must achieve the following new source performance standards (NSPS):
table: Subpart AU—Nickel Carbonate
40 CFR 415.475 (NSPS)
Copper 0.13 0.042
Copper0.042 Kg/kkg (or pounds per/1,000 lb) or productmonthly averageas aboveas above
Copper (T)3.3 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart BM—Cobalt Salts Production Subcategory
existing sources (PSES)
table: Subpart BM—Cobalt Salts
40 CFR 415.654 (PSES)
Copper (T) 3.3 1.0
Copper (T)1.0 mg/Lmonthly averageas aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.