Passage Data · Cited limits by place · Use it from your AI

Fluoranthene limits and guidelines in Rhode Island (US-RI)

55 cited rows from 8 instruments, Rhode Island's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Rhode Island (US-RI) and United States. Everything held for Rhode Island

Rhode Island: surface water 5 · United States: drinking water 1, surface water 3, effluent 41, soil 3, product 2

Rhode Island (US-RI): 5 rows

Surface water: 5 rows

250-RICR-150-05-1 Water Quality Regulations (Rhode Island), § 1.26(J) acute and chronic aquatic life criteria for… · effective January 13, 2026, as US EPA posts it in effect for Clean Water Act purposes (the chronic mercury revisions and the freshwater xylene criteria still… · 5 guidelines
ValueStatisticApplies whenCite
199* µg/L1-hour averagereceiving water: freshwater
fresh waters (salinity 1 ppt or less; brackish 1-10 ppt takes the more stringent)
250-RICR-150-05-1 § 1.26(J) · p. 166
4.4* µg/L4-day averagereceiving water: freshwater
fresh waters (salinity 1 ppt or less)
as above
20 µg/L—receiving water: freshwater
waters whose designated route of exposure is drinking water and aquatic organisms
as above
20 µg/L—receiving water: freshwater
waters whose designated route of exposure is aquatic organisms only
as above
20 µg/L—receiving water: marine
waters whose designated route of exposure is aquatic organisms only
as above

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

United States (US): 50 rows

Drinking water: 1 row

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water · November 2024 · 1 guideline
ParameterValueApplies whenCite
~Fluoranthene800 µg/LTap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024source

Surface water: 3 rows

EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only) · EPA web table (fetched 2026-10-09); each criterion carries its publication year · 3 guidelines
Every row: EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
ValueApplies whenCite
20 µg/Lreceiving water: freshwater
consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)
National Recommended Water Quality Criteria — Human Health Criteria Table
Fluoranthene (P) 206440 20 20 2015
20 µg/Lreceiving water: freshwater
consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt)
as above
20 µg/Lreceiving water: marine
consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt)
as above

Effluent: 41 rows

40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers · eCFR as of 2026-08-01 · 10 limits
Every row: (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i
ValueStatisticApplies whenCite
68 µg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Fluoranthene 68 25
68 µg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Fluoranthene 68 25
25 µg/Lmonthly averagedischarge to surface water
the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Fluoranthene 68 25
25 µg/Lmonthly averagedischarge to surface water
the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Fluoranthene 68 25
54 µg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Fluoranthene 54 22
54 µg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Fluoranthene 54 22
22 µg/Lmonthly averagedischarge to surface water
the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Fluoranthene 54 22
22 µg/Lmonthly averagedischarge to surface water
the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (NSPS)
Fluoranthene 54 22
54 µg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart K—Indirect Discharge Point Sources
new sources (PSNS)
(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…
40 CFR 414.111 (PSNS)
Fluoranthene 54 22
22 µg/Lmonthly averageas aboveas above
40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05 · 28 limits, 10 shown
ValueStatisticApplies whenCite
0.0537 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.21 (BPT)
Fluoranthene 0.0537 0.0268
0.0268 mg/Lmonthly averageas aboveas above
0.787 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (PSES)
table: Pretreatment Standards (PSES)
40 CFR 437.25 (PSES)
Fluoranthene 0.787 0.393
0.393 mg/Lmonthly averageas aboveas above
0.0537 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
40 CFR 437.42 (BPT)
Fluoranthene 0.0537 0.0268
0.0268 mg/Lmonthly averageas aboveas above
0.0537 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
as above
0.0268 mg/Lmonthly averageas aboveas above
0.0537 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
as above
0.0268 mg/Lmonthly averageas aboveas above

All 28 rows from 40 CFR Part 437 — The centralized waste treatment point source category

40 CFR Part 442 — Transportation equipment cleaning point source category · eCFR as of 2026-10-05 · 3 limits
Every row: the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos
ValueStatisticApplies whenCite
0.076 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: Table—Effluent Limitations
40 CFR 442.21 (BPT)
Fluoranthene 0.076
0.076 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Table—Pretreatment Standards'
40 CFR 442.25 (PSES)
Fluoranthene 0.076
0.076 mg/Ldaily maximumdischarge to a sewer (pretreatment)
new sources (PSNS)
table: Table—Pretreatment Standards
40 CFR 442.26 (PSNS)
Fluoranthene 0.076

Soil: 3 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil · November 2024 · 3 guidelines
ParameterValueApplies whenCite
~Fluoranthene2400 mg/kgResident Soil (mg/kg)source
~Fluoranthene30000 mg/kgIndustrial Soil (mg/kg)as above
~Fluoranthene89 mg/kgProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above

Product: 2 rows

40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 2 limits
Every row: (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.
ValueStatisticCite
0.068 mg/Lcomposite sample40 CFR 268.48, Table UTS, Organic Constituents, wastewater standard
Fluoranthene 206-44-0 0.068 3.4
3.4 mg/kginstantaneous40 CFR 268.48, Table UTS, Organic Constituents, nonwastewater standard
Fluoranthene 206-44-0 0.068 3.4

This page shows 37 of 55 rows: every instrument, each with its first 10 rows or all of them. All 55 as JSON, 200 a page.

What was searched

69 instruments we hold for Rhode Island (US-RI) and United States, for 24 names matching “fluoranthene” (each in the JSON). 8 have a row, in the tables above; 61 have none.

61 instruments with no row for fluoranthene
  1. 40 CFR 52.21 — Prevention of significant deterioration of air quality · eCFR 2026-08-01
  2. 40 CFR 63.2 — Definitions (major source of hazardous air pollutants) · eCFR 2026-08-01
  3. 40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity… · eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)
  4. 40 CFR Part 50, National Primary and Secondary Ambient Air Quality Standards, §§ 50.4–50.21 (eCFR as of 2026-08-01) · 90 FR 4651, Jan. 16, 2025
  5. 40 CFR Part 133 — Secondary Treatment Regulation · eCFR as of 2026-10-05
  6. 40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01
  7. 40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01
  8. 40 CFR Part 405 — Dairy products processing point source category · eCFR as of 2026-10-05
  9. 40 CFR Part 406 — Grain mills point source category · eCFR as of 2026-10-05
  10. 40 CFR Part 407 — Canned and preserved fruits and vegetables processing point source category · eCFR as of 2026-10-05
  11. 40 CFR Part 408 — Canned and preserved seafood processing point source category · eCFR as of 2026-10-05
  12. 40 CFR Part 409 — Sugar processing point source category · eCFR as of 2026-10-05
  13. 40 CFR Part 410 — Textile mills point source category · eCFR as of 2026-10-05
  14. 40 CFR Part 411 — Cement manufacturing point source category · eCFR as of 2026-10-05
  15. 40 CFR Part 412 — Concentrated animal feeding operations (CAFO) point source category · eCFR as of 2026-10-05
  16. 40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05
  17. 40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01
  18. 40 CFR Part 417 — Soap and detergent manufacturing point source category · eCFR as of 2026-10-05
  19. 40 CFR Part 418 — Fertilizer manufacturing point source category · eCFR as of 2026-08-01
  20. 40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05
  21. 40 CFR Part 420 — Iron and steel manufacturing point source category · eCFR as of 2026-10-05
  22. 40 CFR Part 421 — Nonferrous metals manufacturing point source category · eCFR as of 2026-10-05
  23. 40 CFR Part 422 — Phosphate manufacturing point source category · eCFR as of 2026-08-01
  24. 40 CFR Part 423 — Steam electric power generating point source category · eCFR as of 2026-10-05
  25. 40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05
  26. 40 CFR Part 425 — Leather tanning and finishing point source category · eCFR as of 2026-10-05
  27. 40 CFR Part 426 — Glass manufacturing point source category · eCFR as of 2026-10-05
  28. 40 CFR Part 427 — Asbestos manufacturing point source category · eCFR as of 2026-10-05
  29. 40 CFR Part 428 — Rubber manufacturing point source category · eCFR as of 2026-10-05
  30. 40 CFR Part 429 — Timber products processing point source category · eCFR as of 2026-10-05
  31. 40 CFR Part 430 — The pulp, paper, and paperboard point source category · eCFR as of 2026-10-05
  32. 40 CFR Part 432 — Meat and poultry products point source category · eCFR as of 2026-10-05
  33. 40 CFR Part 433 — Metal finishing point source category · eCFR as of 2026-10-05
  34. 40 CFR Part 434 — Coal mining point source category BPT, BAT, BCT limitations and new source performance standards · eCFR as of 2026-10-05
  35. 40 CFR Part 435 — Oil and gas extraction point source category · eCFR as of 2026-10-05
  36. 40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05
  37. 40 CFR Part 438 — Metal products and machinery point source category · eCFR as of 2026-10-05
  38. 40 CFR Part 439 — Pharmaceutical manufacturing point source category · eCFR as of 2026-10-05
  39. 40 CFR Part 440 — Ore mining and dressing point source category · eCFR as of 2026-10-05
  40. 40 CFR Part 443 — Effluent limitations guidelines for existing sources and standards of performance and pretreatment… · eCFR as of 2026-10-05
  41. 40 CFR Part 444 — Waste combustors point source category · eCFR as of 2026-10-05
  42. 40 CFR Part 445 — Landfills point source category · eCFR as of 2026-10-05
  43. 40 CFR Part 446 — Paint formulating point source category · eCFR as of 2026-10-05
  44. 40 CFR Part 447 — Ink formulating point source category · eCFR as of 2026-10-05
  45. 40 CFR Part 449 — Airport deicing point source category · eCFR as of 2026-10-05
  46. 40 CFR Part 454 — Gum and wood chemicals manufacturing point source category · eCFR as of 2026-10-05
  47. 40 CFR Part 455 — Pesticide chemicals · eCFR as of 2026-10-05
  48. 40 CFR Part 457 — Explosives manufacturing point source category · eCFR as of 2026-10-05
  49. 40 CFR Part 458 — Carbon black manufacturing point source category · eCFR as of 2026-08-01
  50. 40 CFR Part 459 — Photographic point source category · eCFR as of 2026-10-05
  51. 40 CFR Part 460 — Hospital point source category · eCFR as of 2026-10-05
  52. 40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05
  53. 40 CFR Part 463 — Plastics molding and forming point source category · eCFR as of 2026-10-05
  54. 40 CFR Part 464 — Metal molding and casting point source category · eCFR as of 2026-10-05
  55. 40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05
  56. 40 CFR Part 466 — Porcelain enameling point source category · eCFR as of 2026-10-05
  57. 40 CFR Part 467 — Aluminum forming point source category · eCFR as of 2026-10-05
  58. 40 CFR Part 468 — Copper forming point source category · eCFR as of 2026-10-05
  59. 40 CFR Part 469 — Electrical and electronic components point source category · eCFR as of 2026-10-05
  60. 40 CFR Part 471 — Nonferrous metals forming and metal powders point source category · eCFR as of 2026-10-05
  61. EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC) · EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the fluoranthene limits in Rhode Island? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=fluoranthene&place=US-RI; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.