Passage Data · Cited limits by place · Use it from your AI

pH in Pennsylvania (US-PA): 40 CFR Part 424 — Ferroalloy manufacturing point source category

10 rows for ph in this instrument. Every instrument for ph in Pennsylvania

United States (US): 10 rows

Effluent: 10 rows

40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05 · 10 limits
Every row: discharge to surface water
ValueApplies whenCite
6.0 to 9.0 pH unitsthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.12 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.15 (NSPS)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.22 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.25 (NSPS)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart C—Slag Processing Subcategory
existing sources (BPT)
40 CFR 424.32 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart C—Slag Processing Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
40 CFR 424.35 (NSPS)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart D—Covered Calcium Carbide Furnaces With Wet Air Pollution Control Devices Subcategory
existing sources (BPT)
40 CFR 424.42 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart F—Electrolytic Manganese Products Subcategory
existing sources (BPT)
(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best practicable control technology currently available:
40 CFR 424.62 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart F—Electrolytic Manganese Products Subcategory
existing sources (BPT)
(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best practicable control technology currently available:
as above
6.0 to 9.0 pH unitsthe discharge is of the Subpart G—Electrolytic Chromium Subcategory
existing sources (BPT)
40 CFR 424.72 (BPT)
pH ( 1 ) ( 1 )

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.