Passage Data · Cited limits by place · Use it from your AI

Fluoride limits and guidelines in Pennsylvania (US-PA)

1,583 cited rows from 17 instruments, Pennsylvania's own first. Not covered: a permit's own limits, or rules outside the 72 instruments we hold for Pennsylvania (US-PA) and United States. Everything held for Pennsylvania

Pennsylvania: surface water 1, groundwater 6, soil 15 · United States: drinking water 7, effluent 1,538, soil 14, air emission 1, product 1

Pennsylvania (US-PA): 22 rows

Surface water: 1 row

25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality… · Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page · 1 guideline · Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page.
ValueStatisticApplies whenCite
Daily average 2.0 mg/l. mg/Ldaily averagecritical use PWS (potable water supply): the designated or existing use the criterion protects (§93.7 Table 3)25 Pa. Code §93.7 Table 3 (F)
Fluoride F Daily average 2.0 mg/l. PWS

Groundwater: 6 rows

25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes… · the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs… · 6 guidelines
Every row: the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard
ValueApplies whenCite
4000 µg/Lgroundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, R) · p. 1
4000 µg/Lgroundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, NR) · p. 1
400000 µg/Lgroundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, R) · p. 1
400000 µg/Lgroundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, NR) · p. 1
4000000 µg/Lgroundwater: an aquifer not used or currently planned to be used (§250.304(d))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, R) · p. 1
4000000 µg/Lgroundwater: an aquifer not used or currently planned to be used (§250.304(d))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, NR) · p. 1

Soil: 15 rows

25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil… · the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B… · 15 guidelines
Every row: the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard
ValueApplies whenCite
8800 mg/kga direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))
residential, soil 0-15 feet from the existing ground surface (§250.305(c))
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (R) · p. 1
130000 mg/kga direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))
nonresidential, surface soil 0-2 feet (§250.305(d))
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 0-2 ft) · p. 1
190000 mg/kga direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))
nonresidential, subsurface soil 2-15 feet (§250.305(e))
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 2-15 ft) · p. 1
400 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, 100 X GW MSC) · p. 1
44 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, Generic Value) · p. 1
400 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, 100 X GW MSC) · p. 1
44 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, Generic Value) · p. 1
40000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, 100 X GW MSC) · p. 1
4400 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, Generic Value) · p. 1
40000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, 100 X GW MSC) · p. 1
4400 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, Generic Value) · p. 1
190000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer not used or currently planned to be used (§250.304(d))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, 100 X GW MSC) · p. 1
44000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer not used or currently planned to be used (§250.304(d))
residential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, Generic Value) · p. 1
190000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))
groundwater: an aquifer not used or currently planned to be used (§250.304(d))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, 100 X GW MSC) · p. 1
44000 mg/kga soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))
the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))
groundwater: an aquifer not used or currently planned to be used (§250.304(d))
nonresidential standard
25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, Generic Value) · p. 1

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

United States (US): 1,561 rows

Drinking water: 7 rows

40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01 · 2 rows
ValueKindApplies whenCite
4.0 mg/lguideline40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals.141.51, 141.62
4.0 mg/llimit40 CFR 141.2: Maximum contaminant level means the maximum permissible level of a contaminant in water which is delivered to any user of a public water system.as above
40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01 · 1 guideline
ValueApplies whenCite
2.0 mg/l40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States.143.3
US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water · November 2024 · 4 guidelines
Every row: Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024
ParameterValueCite
Fluoride800 µg/Lsource
Sodium Fluoride1000 µg/Las above
Fluorine (Soluble Fluoride)1200 µg/Las above
Hydrogen Fluoride28 µg/Las above

Effluent: 1,538 rows

40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01 · 12 limits
ParameterValueStatisticApplies whenCite
Fluoride (T)6.1 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
existing sources (BPT)
table: Subpart H—Hydrofluoric Acid
40 CFR 415.82 (BPT)
Fluoride (T) 6.1 2.9
Fluoride (T)2.9 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Fluoride (T)3.4 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
existing sources (BAT)
table: Subpart H—Hydrofluoric Acid
40 CFR 415.83 (BAT)
Fluoride (T) 3.4 1.6
Fluoride (T)1.6 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Fluoride (T)3.4 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
table: Subpart H—Hydrofluoric Acid
40 CFR 415.85 (NSPS)
Fluoride (T) 3.4 1.6
Fluoride (T)1.6 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Fluoride (T)100 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory
new sources (PSNS)
table: Subpart H—Hydrofluoric Acid
40 CFR 415.86 (PSNS)
Fluoride (T) 100 50
Fluoride (T)50 mg/Lmonthly averageas aboveas above
Fluoride (T)1.3 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory
existing sources (BPT)
table: Subpart W—Aluminum Fluoride
column: Pollutant or pollutant property
40 CFR 415.232 (BPT)
Fluoride (T) 1.3 0.63
Fluoride (T)0.63 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Fluoride50 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart BC—Sodium Fluoride Production Subcategory
existing sources (PSES)
table: Subpart BC—Sodium Fluoride
40 CFR 415.554 (PSES)
Fluoride 50 25
Fluoride25 mg/Lmonthly averageas aboveas above
40 CFR Part 418 — Fertilizer manufacturing point source category · eCFR as of 2026-08-01 · 12 limits
Every row: discharge to surface water; the discharge is of the Subpart A—Phosphate Subcategory
ValueStatisticApplies whenCite
75 mg/Ldaily maximumexisting sources (BPT)
(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:
40 CFR 418.12 (BPT)
Fluoride 75 25
25 mg/Lmonthly averageas aboveas above
75 mg/Ldaily maximumexisting sources (BPT)
(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:
as above
25 mg/Lmonthly averageas aboveas above
75 mg/Ldaily maximumexisting sources (BAT)
(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:
40 CFR 418.13 (BAT)
Fluoride 75 25
25 mg/Lmonthly averageas aboveas above
75 mg/Ldaily maximumexisting sources (BAT)
(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:
as above
25 mg/Lmonthly averageas aboveas above
75 mg/Ldaily maximumnew sources (NSPS)
(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:
40 CFR 418.15 (NSPS)
Fluoride 75 25
25 mg/Lmonthly averageas aboveas above
75 mg/Ldaily maximumnew sources (NSPS)
(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:
as above
25 mg/Lmonthly averageas aboveas above
40 CFR Part 421 — Nonferrous metals manufacturing point source category · eCFR as of 2026-10-05 · 591 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory
ValueStatisticApplies whenCite
2.0 kg/kkg of productdaily maximumexisting sources (BPT)40 CFR 421.22 (BPT)
Fluoride 2.0 1.0
1.0 kg/kkg of productmonthly averageas aboveas above
8.092 mg/kg (pounds per million pounds) of paste produceddaily maximumexisting sources (BAT)
(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control
table: BAT Effluent Limitations
40 CFR 421.23 (BAT)
Fluoride 8.092 3.591
3.591 mg/kg (pounds per million pounds) of paste producedmonthly averageas aboveas above
12.440 mg/kg (pounds per million pounds) of anodes castdaily maximumexisting sources (BAT)
(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.
table: BAT Effluent Limitations
40 CFR 421.23 (BAT)
Fluoride 12.440 5.518
5.518 mg/kg (pounds per million pounds) of anodes castmonthly averageas aboveas above
257.300 mg/kg (pounds per million pounds) of anodes bakeddaily maximumexisting sources (BAT)
(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).
table: BAT Effluent Limitations
40 CFR 421.23 (BAT)
Fluoride 257.300 114.200
114.200 mg/kg (pounds per million pounds) of anodes bakedmonthly averageas aboveas above
2.975 mg/kg (pounds per million pounds) of anodes bakeddaily maximumexisting sources (BAT)
(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).
table: BAT Effluent Limitations
40 CFR 421.23 (BAT)
Fluoride 2.975 1.320
1.320 mg/kg (pounds per million pounds) of anodes bakedmonthly averageas aboveas above

All 591 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category

40 CFR Part 422 — Phosphate manufacturing point source category · eCFR as of 2026-08-01 · 30 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart D—Defluorinated Phosphate Rock Subcategory; table: [Milligrams per liter]
ParameterValueStatisticApplies whenCite
Fluoride (as F)75 mg/Ldaily maximumexisting sources (BPT)
(c) The concentration of pollutants discharged in process waste water pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:
40 CFR 422.42 (BPT)
Fluoride (as F) 75 25
Fluoride (as F)25 mg/Lmonthly averageas aboveas above
Fluoride (as F)75 mg/Ldaily maximumexisting sources (BPT)
(d) The concentration of pollutants discharged in contaminated nonprocess wastewater shall not exceed the values listed in the following table:
as above
Fluoride (as F)25 mg/Lmonthly averageas aboveas above
Fluoride (as F)75 mg/Ldaily maximumexisting sources (BAT)
(c) The concentration of pollutants discharged in process waste water pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:
40 CFR 422.43 (BAT)
Fluoride (as F) 75 25
Fluoride (as F)25 mg/Lmonthly averageas aboveas above
Fluoride75 mg/Ldaily maximumexisting sources (BAT)
(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:
40 CFR 422.43 (BAT)
Fluoride 75 25
Fluoride25 mg/Lmonthly averageas aboveas above
Fluoride (as F)75 mg/Ldaily maximumnew sources (NSPS)
(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:
40 CFR 422.45 (NSPS)
Fluoride (as F) 75 25
Fluoride (as F)25 mg/Lmonthly averageas aboveas above

All 30 rows from 40 CFR Part 422 — Phosphate manufacturing point source category

40 CFR Part 426 — Glass manufacturing point source category · eCFR as of 2026-10-05 · 24 limits, 10 shown
ValueStatisticApplies whenCite
140.0 g/kkg of furnace pulldaily maximumdischarge to surface water
the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory
existing sources (BPT)
40 CFR 426.112 (BPT)
Fluoride 140.0 70.0
70.0 g/kkg of furnace pullmonthly averageas aboveas above
120.0 g/kkg of furnace pulldaily maximumdischarge to surface water
the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory
existing sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams.
40 CFR 426.113 (BAT)
Fluoride 120.0 60.0
60.0 g/kkg of furnace pullmonthly averageas aboveas above
120.0 g/kkg of furnace pulldaily maximumdischarge to surface water
the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the…
40 CFR 426.115 (NSPS)
Fluoride 120.0 60.0
60.0 g/kkg of furnace pullmonthly averageas aboveas above
120.0 g/kkg of furnace pulldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory
new sources (PSNS)
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject …
40 CFR 426.116 (PSNS)
Fluoride 120.0 60.0
60.0 g/kkg of furnace pullmonthly averageas aboveas above
230.0 g/kkg of product frosteddaily maximumdischarge to surface water
the discharge is of the Subpart L—Incandescent Lamp Envelope Manufacturing Subcategory
existing sources (BPT)
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
40 CFR 426.122 (BPT)
Fluoride 230.0 115.0
115.0 g/kkg of product frostedmonthly averageas aboveas above

All 24 rows from 40 CFR Part 426 — Glass manufacturing point source category

40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05 · 2 limits
Every row: discharge to surface water; the discharge is of the Subpart D—Industrial Sand Subcategory; existing sources (BPT); (3) Process generated waste water from facilities employing HF flotation shall not exceed the following limitations:; table: [Metric units, kg/kkg of total product; English units, lb/1,000 lb of total product]
ParameterValueStatisticCite
Total fluoride.006 kg/kkgdaily maximum40 CFR 436.42 (BPT)
Total fluoride .006 .003
Total fluoride.003 kg/kkgmonthly averageas above
40 CFR Part 469 — Electrical and electronic components point source category · eCFR as of 2026-10-05 · 20 limits, 10 shown
Every row: discharge to surface water
ParameterValueStatisticApplies whenCite
Fluoride (T)32.0 mg/Ldaily maximumthe discharge is of the Subpart A—Semiconductor Subcategory
existing sources (BAT)
table: Subpart A—Semiconductor BAT Effluent Limitations
40 CFR 469.15 (BAT)
Fluoride (T) 32.0 17.4
Fluoride (T)17.4 mg/Lmonthly averageas aboveas above
Fluoride (T)32.0 mg/Ldaily maximumthe discharge is of the Subpart A—Semiconductor Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards (NSPS).
table: Subpart A—Semiconductor NSPS Effluent Limitations
40 CFR 469.17 (NSPS)
Fluoride (T) 32.0 17.4
Fluoride (T)17.4 mg/Lmonthly averageas aboveas above
Fluoride (T)32.0 mg/Ldaily maximumthe discharge is of the Subpart B—Electronic Crystals Subcategory
existing sources (BPT)
table: Subpart B—Electronic Crystals BPT Effluent Limitations
40 CFR 469.24 (BPT)
Fluoride (T) 32.0 17.4
Fluoride (T)17.4 mg/Lmonthly averageas aboveas above
Fluoride32.0 mg/Ldaily maximumthe discharge is of the Subpart B—Electronic Crystals Subcategory
existing sources (BAT)
table: Subpart B—Electronic Crystals BAT Effluent Limitations
40 CFR 469.25 (BAT)
Fluoride 32.0 17.4
Fluoride17.4 mg/Lmonthly averageas aboveas above
Fluoride(T)32.0 mg/Ldaily maximumthe discharge is of the Subpart B—Electronic Crystals Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
table: Subpart B—Electronic Crystals NSPS Effluent Limitations
40 CFR 469.27 (NSPS)
Fluoride(T) 32.0 17.4
Fluoride(T)17.4 mg/Lmonthly averageas aboveas above

All 20 rows from 40 CFR Part 469 — Electrical and electronic components point source category

40 CFR Part 471 — Nonferrous metals forming and metal powders point source category · eCFR as of 2026-10-05 · 847 limits, 10 shown
Every row: discharge to surface water; the discharge is of the Subpart B—Magnesium Forming Subcategory; existing sources (BPT); table: Subpart B—BPT
ValueStatisticApplies whenCite
4.440 mg/off-kg (pounds per million off-pounds) of magnesium rolled with emulsionsdaily maximum(a) Rolling spent emulsions.40 CFR 471.21 (BPT)
Fluoride 4.440 1.97
1.97 mg/off-kg (pounds per million off-pounds) of magnesium rolled with emulsionsmonthly averageas aboveas above
172 mg/off-kg (pounds per million off-pounds) of forged magnesium cooled with waterdaily maximum(c) Forging contact cooling water.40 CFR 471.21 (BPT)
Fluoride 172 76.3
76.3 mg/off-kg (pounds per million off-pounds) of forged magnesium cooled with watermonthly averageas aboveas above
2.38 mg/off-kg (pounds per million off-pounds) of magnesium forgeddaily maximum(d) Forging equipment cleaning wastewater.40 CFR 471.21 (BPT)
Fluoride 2.38 1.06
1.06 mg/off-kg (pounds per million off-pounds) of magnesium forgedmonthly averageas aboveas above
235 mg/off-kg (pounds per million off-pounds) of magnesium cast with direct chill methodsdaily maximum(e) Direct chill casting contact cooling water.40 CFR 471.21 (BPT)
Fluoride 235 105
105 mg/off-kg (pounds per million off-pounds) of magnesium cast with direct chill methodsmonthly averageas aboveas above
27.8 mg/off-kg (pounds per million off-pounds) of magnesium surface treateddaily maximum(f) Surface treatment spent baths.40 CFR 471.21 (BPT)
Fluoride 27.8 12.3
12.3 mg/off-kg (pounds per million off-pounds) of magnesium surface treatedmonthly averageas aboveas above

All 847 rows from 40 CFR Part 471 — Nonferrous metals forming and metal powders point source category

Soil: 14 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil · November 2024 · 14 rows
ParameterValueKindApplies whenCite
Fluoride3100 mg/kgguidelineResident Soil (mg/kg)source
Fluoride47000 mg/kgguidelineIndustrial Soil (mg/kg)as above
Fluoride120 mg/kgguidelineProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Fluoride600 mg/kgreference value (not a limit)Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1as above
Sodium Fluoride3900 mg/kgguidelineResident Soil (mg/kg)as above
Sodium Fluoride58000 mg/kgguidelineIndustrial Soil (mg/kg)as above
Sodium Fluoride150 mg/kgguidelineProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Sodium Fluoride600 mg/kgreference value (not a limit)Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1as above
Fluorine (Soluble Fluoride)4700 mg/kgguidelineResident Soil (mg/kg)as above
Fluorine (Soluble Fluoride)70000 mg/kgguidelineIndustrial Soil (mg/kg)as above
Fluorine (Soluble Fluoride)180 mg/kgguidelineProtection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1as above
Fluorine (Soluble Fluoride)600 mg/kgreference value (not a limit)Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1as above
Hydrogen Fluoride3100 mg/kgguidelineResident Soil (mg/kg)as above
Hydrogen Fluoride47000 mg/kgguidelineIndustrial Soil (mg/kg)as above

Air emission: 1 row

40 CFR 52.21 — Prevention of significant deterioration of air quality · eCFR 2026-08-01 · 1 threshold
ParameterValueCite
Fluorides3 tpy52.21(b)(23)(i)
Fluorides: 3 tpy

Product: 1 row

40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 1 limit
ValueStatisticApplies whenCite
35 mg/Lcomposite sample(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard
Fluoride 5 16984-48-8 35 NA

This page shows 121 of 1,583 rows: every instrument, each with its first 10 rows or all of them. All 1,583 as JSON, 200 a page.

1 NPDES permit in Pennsylvania went over a fluoride limit in their last 12 months of reports: the list as JSON.

What was searched

72 instruments we hold for Pennsylvania (US-PA) and United States, for 13 names matching “fluoride” (each in the JSON). 17 have a row, in the tables above; 55 have none.

55 instruments with no row for fluoride
  1. 25 Pa. Code §95.10 — Treatment requirements for new and expanding mass loadings of Total Dissolved Solids (TDS) · Pennsylvania Code as served 2026-10-09: §95.10 adopted August 20, 2010, effective August 21, 2010, 40 Pa.B. 4835 · Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §95.10 adopted August 20, 2010, effective August 21, 2010, 40 Pa.B. 4835.
  2. 40 CFR 63.2 — Definitions (major source of hazardous air pollutants) · eCFR 2026-08-01
  3. 40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity… · eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)
  4. 40 CFR Part 50, National Primary and Secondary Ambient Air Quality Standards, §§ 50.4–50.21 (eCFR as of 2026-08-01) · 90 FR 4651, Jan. 16, 2025
  5. 40 CFR Part 133 — Secondary Treatment Regulation · eCFR as of 2026-10-05
  6. 40 CFR Part 405 — Dairy products processing point source category · eCFR as of 2026-10-05
  7. 40 CFR Part 406 — Grain mills point source category · eCFR as of 2026-10-05
  8. 40 CFR Part 407 — Canned and preserved fruits and vegetables processing point source category · eCFR as of 2026-10-05
  9. 40 CFR Part 408 — Canned and preserved seafood processing point source category · eCFR as of 2026-10-05
  10. 40 CFR Part 409 — Sugar processing point source category · eCFR as of 2026-10-05
  11. 40 CFR Part 410 — Textile mills point source category · eCFR as of 2026-10-05
  12. 40 CFR Part 411 — Cement manufacturing point source category · eCFR as of 2026-10-05
  13. 40 CFR Part 412 — Concentrated animal feeding operations (CAFO) point source category · eCFR as of 2026-10-05
  14. 40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05
  15. 40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers · eCFR as of 2026-08-01
  16. 40 CFR Part 417 — Soap and detergent manufacturing point source category · eCFR as of 2026-10-05
  17. 40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05
  18. 40 CFR Part 420 — Iron and steel manufacturing point source category · eCFR as of 2026-10-05
  19. 40 CFR Part 423 — Steam electric power generating point source category · eCFR as of 2026-10-05
  20. 40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05
  21. 40 CFR Part 425 — Leather tanning and finishing point source category · eCFR as of 2026-10-05
  22. 40 CFR Part 427 — Asbestos manufacturing point source category · eCFR as of 2026-10-05
  23. 40 CFR Part 428 — Rubber manufacturing point source category · eCFR as of 2026-10-05
  24. 40 CFR Part 429 — Timber products processing point source category · eCFR as of 2026-10-05
  25. 40 CFR Part 430 — The pulp, paper, and paperboard point source category · eCFR as of 2026-10-05
  26. 40 CFR Part 432 — Meat and poultry products point source category · eCFR as of 2026-10-05
  27. 40 CFR Part 433 — Metal finishing point source category · eCFR as of 2026-10-05
  28. 40 CFR Part 434 — Coal mining point source category BPT, BAT, BCT limitations and new source performance standards · eCFR as of 2026-10-05
  29. 40 CFR Part 435 — Oil and gas extraction point source category · eCFR as of 2026-10-05
  30. 40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05
  31. 40 CFR Part 438 — Metal products and machinery point source category · eCFR as of 2026-10-05
  32. 40 CFR Part 439 — Pharmaceutical manufacturing point source category · eCFR as of 2026-10-05
  33. 40 CFR Part 440 — Ore mining and dressing point source category · eCFR as of 2026-10-05
  34. 40 CFR Part 442 — Transportation equipment cleaning point source category · eCFR as of 2026-10-05
  35. 40 CFR Part 443 — Effluent limitations guidelines for existing sources and standards of performance and pretreatment… · eCFR as of 2026-10-05
  36. 40 CFR Part 444 — Waste combustors point source category · eCFR as of 2026-10-05
  37. 40 CFR Part 445 — Landfills point source category · eCFR as of 2026-10-05
  38. 40 CFR Part 446 — Paint formulating point source category · eCFR as of 2026-10-05
  39. 40 CFR Part 447 — Ink formulating point source category · eCFR as of 2026-10-05
  40. 40 CFR Part 449 — Airport deicing point source category · eCFR as of 2026-10-05
  41. 40 CFR Part 454 — Gum and wood chemicals manufacturing point source category · eCFR as of 2026-10-05
  42. 40 CFR Part 455 — Pesticide chemicals · eCFR as of 2026-10-05
  43. 40 CFR Part 457 — Explosives manufacturing point source category · eCFR as of 2026-10-05
  44. 40 CFR Part 458 — Carbon black manufacturing point source category · eCFR as of 2026-08-01
  45. 40 CFR Part 459 — Photographic point source category · eCFR as of 2026-10-05
  46. 40 CFR Part 460 — Hospital point source category · eCFR as of 2026-10-05
  47. 40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05
  48. 40 CFR Part 463 — Plastics molding and forming point source category · eCFR as of 2026-10-05
  49. 40 CFR Part 464 — Metal molding and casting point source category · eCFR as of 2026-10-05
  50. 40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05
  51. 40 CFR Part 466 — Porcelain enameling point source category · eCFR as of 2026-10-05
  52. 40 CFR Part 467 — Aluminum forming point source category · eCFR as of 2026-10-05
  53. 40 CFR Part 468 — Copper forming point source category · eCFR as of 2026-10-05
  54. EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC) · EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year
  55. EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only) · EPA web table (fetched 2026-10-09); each criterion carries its publication year
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the fluoride limits in Pennsylvania? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=fluoride&place=US-PA; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.