Passage Data · Cited limits by place · Use it from your AI
1,786 cited rows from 48 instruments, Oregon's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Oregon (US-OR) and United States. Everything held for Oregon
United States: drinking water 1, surface water 3, effluent 1,782
The one instrument we hold for Oregon (US-OR) has no row for ph. The rows below are from the place above it, which we search too.
| Value | Applies when | Cite |
|---|---|---|
| 6.5-8.5 | 40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States. | 143.3 |
| Value | Applies when | Cite |
|---|---|---|
| 6.5 – 9 pH units | receiving water: freshwater Freshwater CCC (chronic): criterion continuous concentration, chronic | National Recommended Aquatic Life Criteria tablepH — — 6.5 – 9 — 6.5 – 8.5 1986 |
| 6.5 – 8.5 pH units | receiving water: marine Saltwater CCC (chronic): criterion continuous concentration, chronic | as above |
| Value | Applies when | Cite |
|---|---|---|
| 5 – 9 pH units | EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use receiving water: freshwater consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns) | National Recommended Water Quality Criteria — Human Health Criteria TablepH — 5 – 9 — 1986 |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | stream: sanitary discharge to surface water a publicly owned treatment works (POTW): the part sets the effluent quality attainable by secondary treatment, which NPDES permits for POTWs carry (40 CFR 133.100, 133.102) unless the POTW demonstrates that inorganic chemicals are not added as part of treatment and industrial contributions do not move the pH outside 6.0-9.0 (§ 133.102(c)) | 40 CFR 133.102 (secondary treatment)(c) pH. The effluent values for pH shall be maintained within the limits of 6.0 to 9.0 unless the publicly owned treatment works demonstrates that: (1) Inorganic chemicals are not added to the waste stream as part of the treatment process; and (2) contributions from industrial sources do not cause the pH of the effluent to be less than 6.0 or greater than 9.0. |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Receiving Stations Subcategory existing sources (BPT) (a) For receiving stations receiving more than 150,000 lb/day of milk equivalent (15,600 lb/day or more of BOD 5 input). | 40 CFR 405.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Receiving Stations Subcategory existing sources (BPT) (b) For receiving stations receiving 150,000 lb/day or less of milk equivalent (under 15,600 lb/day of BOD 5 input). | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Receiving Stations Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 405.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Fluid Products Subcategory existing sources (BPT) (a) For fluid products plants receiving more than 250,000 lb/day of milk equivalent (more than 25,900 lb/day of BOD 5 input). | 40 CFR 405.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Fluid Products Subcategory existing sources (BPT) (b) For fluid products plants receiving 250,000 lb/day or less of milk equivalent (less than 25,900 lb/day of BOD 5 input). | as above |
All 36 rows from 40 CFR Part 405 — Dairy products processing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Corn Wet Milling Subcategory existing sources (BPT) | 40 CFR 406.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Corn Wet Milling Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 406.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Corn Wet Milling Subcategory existing sources (BCT) (a) Subject to the provisions in paragraph (b) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 406.17 (BCT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Corn Dry Milling Subcategory existing sources (BPT) | 40 CFR 406.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Corn Dry Milling Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this part: | 40 CFR 406.25 (NSPS)pH ( 1 ) ( 1 ) |
All 13 rows from 40 CFR Part 406 — Grain mills point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Apple Juice Subcategory existing sources (BPT) | 40 CFR 407.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Apple Juice Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 407.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Apple Products Subcategory existing sources (BPT) | 40 CFR 407.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Apple Products Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 407.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Citrus Products Subcategory existing sources (BPT) | 40 CFR 407.32 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Farm-Raised Catfish Processing Subcategory existing sources (BPT) | 40 CFR 408.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Farm-Raised Catfish Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 408.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Conventional Blue Crab Processing Subcategory existing sources (BPT) | 40 CFR 408.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Conventional Blue Crab Processing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 408.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Mechanized Blue Crab Processing Subcategory existing sources (BPT) | 40 CFR 408.32 (BPT)pH ( 1 ) ( 1 ) |
All 66 rows from 40 CFR Part 408 — Canned and preserved seafood processing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Beet Sugar Processing Subcategory existing sources (BPT) (a) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results from barometric condensing operations only. | 40 CFR 409.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Beet Sugar Processing Subcategory existing sources (BPT) (b) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results, in whole or in part, from barometric condensing operations and any other beet sugar processing operation. | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Crystalline Cane Sugar Refining Subcategory existing sources (BPT) (a) Any crystalline cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributed to the barometric condenser cooling water to that amount of BOD 5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to t… | 40 CFR 409.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Crystalline Cane Sugar Refining Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 409.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Liquid Cane Sugar Refining Subcategory existing sources (BPT) (a) Any liquid cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD 5 limitation is determined by the addition of the net BOD 5 attributed to the barometric condenser cooling water to that amount of BOD 5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to the tr… | 40 CFR 409.32 (BPT)pH ( 1 ) ( 1 ) |
All 10 rows from 40 CFR Part 409 — Sugar processing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Wool Scouring Subcategory existing sources (BPT) | 40 CFR 410.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Wool Scouring Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 410.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Wool Finishing Subcategory existing sources (BPT) | 40 CFR 410.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Wool Finishing Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 410.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Low Water Use Processing Subcategory existing sources (BPT) table: General Processing | 40 CFR 410.32 (BPT)ph ( 1 ) ( 1 ) |
All 24 rows from 40 CFR Part 410 — Textile mills point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Nonleaching Subcategory existing sources (BPT) | 40 CFR 411.12 (BPT)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Nonleaching Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 411.15 (NSPS)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Nonleaching Subcategory existing sources (BCT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology. | 40 CFR 411.17 (BCT)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Leaching Subcategory existing sources (BPT) | 40 CFR 411.22 (BPT)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Leaching Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 411.25 (NSPS)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory existing sources (BPT) | 40 CFR 411.32 (BPT)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory new sources (NSPS) (a) Subject to the provisions of paragraph (b) of this section the following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 411.35 (NSPS)pH Within the range 6.0 to 9.0. |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Materials Storage Piles Runoff Subcategory existing sources (BCT) (a) Subject to the provisions of paragraph (b) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology. | 40 CFR 411.37 (BCT)pH Within the range 6.0 to 9.0. |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)pH 1 1 |
| 1 mg/L | — | as above | as above |
| 1 mg/L | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)pH 1 1 |
| 1 mg/L | — | as above | as above |
| 7.5 to 10.000 pH units | — | the discharge is of the Subpart D—Anodizing Subcategory table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.44 (PSES)pH ( 1 ) ( 1 ) |
All 9 rows from 40 CFR Part 413 — Electroplating point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Rayon Fibers existing sources (BPT) | 40 CFR 414.21 (BPT)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Rayon Fibers new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR 414.24 (NSPS)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Other Fibers existing sources (BPT) | 40 CFR 414.31 (BPT)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Other Fibers new sources (NSPS) (b) Any new source that does not use end-of-pipe biological treatment and is subject to this subpart must achieve discharges in accordance with § 414.101 of this part, and also must not exceed the quantity (mass) determined by multiplying the process wastewater flow subject to this subpart times the concentrations in the following table. | 40 CFR 414.34 (NSPS)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Thermoplastic Resins existing sources (BPT) | 40 CFR 414.41 (BPT)pH ( 2 ) ( 2 ) |
All 14 rows from 40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers
| Value | Applies when | Cite |
|---|---|---|
| 5.0 to 10.0 pH units | discharge to a sewer (pretreatment) the discharge is of the Subpart A—Aluminum Chloride Production Subcategory existing sources (PSES) table: Subpart A—Aluminum Chloride | 40 CFR 415.14 (PSES)pH Within the range 5.0 to 10.0. |
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart B—Aluminum Sulfate Production Subcategory existing sources (BPT) (d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements: table: Subpart B—Aluminum Sulfate | 40 CFR 415.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart D—Calcium Chloride Production Subcategory existing sources (BPT) table: Subpart D—Calcium Chloride | 40 CFR 415.42 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart E—Calcium Oxide Production Subcategory existing sources (BPT) (d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements: table: Subpart E—Calcium Oxide | 40 CFR 415.52 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production) existing sources (BPT) table: Subpart F—Chlor-Alkali Mercury Cells | 40 CFR 415.62 (BPT)pH ( 1 ) ( 1 ) |
All 49 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory existing sources (BPT) | 40 CFR 417.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 417.13 (BAT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Soap Manufacturing by Batch Kettle Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 417.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Fatty Acid Manufacturing by Fat Splitting Subcategory existing sources (BPT) (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available: | 40 CFR 417.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Fatty Acid Manufacturing by Fat Splitting Subcategory existing sources (BPT) (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section and attributable to the hydrogenation of fatty acids, which may be discharged by a point source subject to the provisions of this subpart in addition to the discharge allowed by paragraph (a) of this section. | as above |
All 69 rows from 40 CFR Part 417 — Soap and detergent manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | existing sources (BPT) | 40 CFR 418.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 418.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | existing sources (BCT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology. | 40 CFR 418.27 (BCT)pH Within the range 6.0 to 9.0. |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | existing sources (BPT) | 40 CFR 419.12 (BPT)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | existing sources (BPT) (c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation … | as above |
| 6.0 to 9.0 pH units | existing sources (BPT) (2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th… | as above |
| 6.0 to 9.0 pH units | existing sources (BCT) (a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). | 40 CFR 419.14 (BCT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | existing sources (BCT) (c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best conventional pollutant control technology by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation allowed fo… | as above |
All 28 rows from 40 CFR Part 419 — Petroleum refining point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | existing sources (BPT) (a) By-product cokemaking—iron and steel. table: Subpart A | 40 CFR 420.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | existing sources (BPT) (b) By-product cokemaking—merchant. table: Subpart A | as above |
| 6.0 to 9.0 pH units | new sources (NSPS) (2) The following standards apply with respect to each new source that commences construction after November 18, 2002: table: Subpart A—New Source Performance Standards (NSPS) | 40 CFR 420.14 (NSPS)pH 2 ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | existing sources (BCT) (a) By-product cokemaking—iron and steel. table: Subpart A | 40 CFR 420.17 (BCT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | existing sources (BCT) (b) By-product cokemaking—merchant. table: Subpart A | as above |
All 143 rows from 40 CFR Part 420 — Iron and steel manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6 to 9 pH units | existing sources (BPT) | 40 CFR 421.22 (BPT)pH ( 1 ) ( 1 ) |
| 7.0 to 10.0 pH units | new sources (NSPS) (a) Subpart B—Anode and Cathode Paste Plant Wet Air. table: Pollution Control—NSPS | 40 CFR 421.24 (NSPS)pH ( 1 ) ( 1 ) |
| 7.0 to 10.0 pH units | new sources (NSPS) (b) Subpart B—Anode Contact Cooling and Briquette Quenching. table: NSPS | as above |
| 7.0 to 10.0 pH units | new sources (NSPS) (c) Subpart B—Anode Bake Plant Wet Air Pollution Control. table: NSPS | as above |
| 7.0 to 10.0 pH units | new sources (NSPS) (d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters). table: NSPS | as above |
All 433 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.5 pH units | existing sources (BPT) (c) The concentration of pollutants discharged in process waste water pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table: | 40 CFR 422.42 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.5 pH units | existing sources (BPT) (d) The concentration of pollutants discharged in contaminated nonprocess wastewater shall not exceed the values listed in the following table: | as above |
| 6.0 to 9.5 pH units | new sources (NSPS) (c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table: | 40 CFR 422.45 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.5 pH units | new sources (NSPS) (d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table: | as above |
| 6.0 to 9.5 pH units | existing sources (BCT) (c) The concentration of pollutants discharged in process waste water pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table: | 40 CFR 422.47 (BCT)pH ( 1 ) ( 1 ) |
All 15 rows from 40 CFR Part 422 — Phosphate manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory existing sources (BPT) | 40 CFR 424.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 424.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory existing sources (BPT) | 40 CFR 424.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 424.25 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Slag Processing Subcategory existing sources (BPT) | 40 CFR 424.32 (BPT)pH ( 1 ) ( 1 ) |
All 10 rows from 40 CFR Part 424 — Ferroalloy manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory existing sources (BPT) | 40 CFR 425.11 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 425.14 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Hair Save, Chrome Tan, Retan-Wet Finish Subcategory existing sources (BPT) | 40 CFR 425.21 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Hair Save, Chrome Tan, Retan-Wet Finish Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 425.24 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Hair Save or Pulp, Non-Chrome Tan, Retan-Wet Finish Subcategory existing sources (BPT) | 40 CFR 425.31 (BPT)pH ( 1 ) ( 1 ) |
All 22 rows from 40 CFR Part 425 — Leather tanning and finishing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Insulation Fiberglass Subcategory existing sources (BPT) (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged in process waste water from advanced air emission control devices, when such water cannot be consumed in the process. | 40 CFR 426.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Plate Glass Manufacturing Subcategory existing sources (BPT) | 40 CFR 426.42 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart E—Float Glass Manufacturing Subcategory existing sources (BPT) | 40 CFR 426.52 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart E—Float Glass Manufacturing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 426.55 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart F—Automotive Glass Tempering Subcategory existing sources (BPT) | 40 CFR 426.62 (BPT)pH ( 1 ) ( 1 ) |
All 21 rows from 40 CFR Part 426 — Glass manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Asbestos-Cement Pipe Subcategory existing sources (BPT) | 40 CFR 427.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Asbestos-Cement Pipe Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 427.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Asbestos-Cement Sheet Subcategory existing sources (BPT) | 40 CFR 427.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Asbestos Paper (Starch Binder) Subcategory existing sources (BPT) | 40 CFR 427.32 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Asbestos Paper (Elastomeric Binder) Subcategory existing sources (BPT) | 40 CFR 427.42 (BPT)pH ( 1 ) ( 1 ) |
All 12 rows from 40 CFR Part 427 — Asbestos manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Tire and Inner Tube Plants Subcategory existing sources (BPT) | 40 CFR 428.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Tire and Inner Tube Plants Subcategory existing sources (BAT) (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 428.13 (BAT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Tire and Inner Tube Plants Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 428.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Emulsion Crumb Rubber Subcategory existing sources (BPT) | 40 CFR 428.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Emulsion Crumb Rubber Subcategory existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 428.23 (BAT)pH ( 1 ) ( 1 ) |
All 30 rows from 40 CFR Part 428 — Rubber manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Barking Subcategory existing sources (BPT) (b) The following limitations constitute the maximum permissible discharge for hydraulic barking installations: table: Subpart A | 40 CFR 429.21 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Barking Subcategory new sources (NSPS) (b) The following limitations constitute the maximum permissible discharge for hydraulic barking installations: table: Subpart A | 40 CFR 429.24 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Veneer Subcategory existing sources (BPT) (b) The following limitations constitute the maximum permissible discharge for softwood veneer manufacturing processes which use direct steaming for the conditioning of logs: table: Subpart B | 40 CFR 429.31 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Veneer Subcategory existing sources (BPT) (c) The following limitations constitute the maximum permissible discharge for hardwood veneer manufacturing processes which use direct steaming for the conditioning of logs: table: Subpart B | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart E—Wet Process Hardboard Subcategory existing sources (BPT) (a) The following limitations apply to plants which produce smooth-one-side (S1S) hardboard: table: Subpart E (S1S) | 40 CFR 429.61 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart E—Wet Process Hardboard Subcategory existing sources (BPT) (b) The following limitations apply to plants which produce smooth-two-sides (S2S) hardboard: table: Subpart E (S2S) | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart G—Wood Preserving Steam Subcategory existing sources (BPT) table: Subpart G | 40 CFR 429.81 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart N—Insulation Board Subcategory existing sources (BPT) table: Subpart N | 40 CFR 429.151 (BPT)pH ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 5.0 to 9.0 pH units | the discharge is of the Subpart A—Dissolving Kraft Subcategory table: Subpart A [BPT effluent limitations] | 40 CFR 430.12 (BPT)pH ( 1 ) ( 1 ) ( 1 ) |
| 5.0 to 9.0 pH units | the discharge is of the Subpart A—Dissolving Kraft Subcategory (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of wet barking operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the p… table: Subpart A [BPT effluent limitations] | as above |
| 5.0 to 9.0 pH units | the discharge is of the Subpart A—Dissolving Kraft Subcategory (c) The following limitations establish the quantity or quality of pollutants or pollutant parameters, controlled by this section, resulting from the use of log washing or chip washing operations, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calcul… table: Subpart A [BPT effluent limitations] | as above |
| 5.0 to 9.0 pH units | the discharge is of the Subpart A—Dissolving Kraft Subcategory (d) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, resulting from the use of log flumes or log ponds, which may be discharged by a point source subject to the provisions of this subpart. These limitations are in addition to the limitations set forth in paragraph (a) of this section and shall be calculated using the … table: Subpart A [BPT effluent limitations] | as above |
| 5.0 to 9.0 pH units | the discharge is of the Subpart B—Bleached Papergrade Kraft and Soda Subcategory table: Subpart B [BPT effluent limitations for bleached kraft facilities where market pulp is produced] | 40 CFR 430.22 (BPT)pH ( 1 ) ( 1 ) ( 1 ) |
All 83 rows from 40 CFR Part 430 — The pulp, paper, and paperboard point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1 mg/L | daily maximum | the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas | 40 CFR 434.22 (BPT)pH 1 1 |
| 1 mg/L | monthly average | as above | as above |
| 1 mg/L | daily maximum | as above | as above |
| 1 mg/L | monthly average | as above | as above |
| 6.0 to 9.0 pH units | — | the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage | 40 CFR 434.32 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Crushed Stone Subcategory (1) Discharges of process generated waste water pollutants from facilities that recycle waste water for use in processing shall not exceed the following limitations: | 40 CFR 436.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Crushed Stone Subcategory (2) Mine dewatering discharges shall not exceed the following limitations: | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Construction Sand and Gravel Subcategory (1) Discharges of process generated waste water pollutants from facilities that recycle waste water for use in processing shall not exceed the following limitations: | 40 CFR 436.32 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Construction Sand and Gravel Subcategory (2) Mine dewatering discharges shall not exceed the following limitations: | as above |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Industrial Sand Subcategory (1) With the exception of operation using HF flotation, discharges of process waste water pollutants from facilities that recycle waste water, for use in the processing shall not exceed the following limitations: | 40 CFR 436.42 (BPT)pH ( 1 ) ( 1 ) |
All 10 rows from 40 CFR Part 436 — Mineral mining and processing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6 to 9. pH units | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)pH ( 2 ) ( 2 ) |
| 6 to 9. pH units | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)pH ( 2 ) ( 2 ) |
| 6 to 9. pH units | the discharge is of the Subpart B—Oils Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.21 (BPT)pH ( 2 ) ( 2 ) |
| 6 to 9. pH units | the discharge is of the Subpart C—Organics Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.31 (BPT)pH ( 2 ) ( 2 ) |
| 6 to 9. pH units | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | 40 CFR 437.42 (BPT)pH ( 2 ) ( 2 ) |
All 11 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Iron Ore Subcategory existing sources (BPT) (a) The concentration of pollutants discharged in mine drainage from mines operated to obtain iron ore shall not exceed: | 40 CFR 440.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Iron Ore Subcategory new sources (NSPS) | 40 CFR 440.14 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Aluminum Ore Subcategory existing sources (BPT) | 40 CFR 440.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Aluminum Ore Subcategory new sources (NSPS) | 40 CFR 440.24 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Uranium, Radium and Vanadium Ores Subcategory existing sources (BPT) (a) The concentration of pollutants discharged in mine drainage from mines, either open-pit or underground, from which uranium, radium and vanadium ores are produced excluding mines using in-situ leach methods shall not exceed: | 40 CFR 440.32 (BPT)pH ( 2 ) ( 2 ) |
All 36 rows from 40 CFR Part 440 — Ore mining and dressing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Asphalt Emulsion Subcategory existing sources (BPT) | 40 CFR 443.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Asphalt Emulsion Subcategory existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 443.13 (BAT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Asphalt Emulsion Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 443.15 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Asphalt Roofing Subcategory existing sources (BPT) | 40 CFR 443.32 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Asphalt Roofing Subcategory existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: | 40 CFR 443.33 (BAT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6 to 9. pH units | discharge to surface water the discharge is of the Subpart A—Commercial Hazardous Waste Combustor Subcategory existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)pH ( 2 ) ( 2 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6 to 9. pH units | the discharge is of the Subpart A—RCRA Subtitle C Hazardous Waste Landfill | 40 CFR 445.11 (BPT)pH ( 2 ) ( 2 ) |
| 6 to 9. pH units | the discharge is of the Subpart B—RCRA Subtitle D Non-Hazardous Waste Landfill | 40 CFR 445.21 (BPT)pH ( 2 ) ( 2 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Gum Rosin and Turpentine Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of gum rosin and turpentine by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 454.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Wood Rosin, Turpentine and Pine Oil Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of wood rosin, turpentine and pine oil by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 454.32 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Tall Oil Rosin, Pitch and Fatty Acids Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of tall oil rosin, pitch and fatty acids by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 454.42 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart E—Essential Oils Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of essential oils by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 454.52 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart F—Rosin-Based Derivatives Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of rosin-based derivatives by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 454.62 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart A—Organic Pesticide Chemicals Manufacturing Subcategory existing sources (BPT) | 40 CFR 455.22 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Manufacture of Explosives Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of explosives by a point source subject to the provisions of this paragraph after application of the best practical control technology currently available: | 40 CFR 457.12 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Explosives Load, Assemble, and Pack Plants Subcategory (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the explosives load, assemble and pack plants by a point source subject to the provisions of this paragraph after application of the best practical control technology currently available: | 40 CFR 457.32 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart A—Photographic Processing Subcategory existing sources (BPT) (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from a photographic processing point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 459.12 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | discharge to surface water the discharge is of the Subpart A—Hospital Category existing sources (BPT) (a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the hospital point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: | 40 CFR 460.12 (BPT)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 7.5 to 10.0 pH units | (1) Subpart A—Pasted and Pressed Powder Anodes. | 40 CFR 461.11 (BPT)pH ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | (2) Subpart A—Electrodeposited Anodes. | as above |
| 7.5 to 10.0 pH units | (3) Subpart A—Impregnated Anodes. | as above |
| 7.5 to 10.0 pH units | (4) Subpart A—Nickel Electrodeposited Cathodes. | as above |
| 7.5 to 10.0 pH units | (5) Subpart A—Nickel Impregnated Cathodes. | as above |
All 52 rows from 40 CFR Part 461 — Battery manufacturing point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Contact Cooling and Heating Water Subcategory existing sources (BPT) table: Subpart A [Contact cooling and heating water] | 40 CFR 463.12 (BPT)pH ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Contact Cooling and Heating Water Subcategory new sources (NSPS) (b) Any new source subject to this subpart must achieve performance standards ( i.e. , mass of pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a new source times the following pollutant concentrations: table: Subpart A [Contact cooling and heating water] | 40 CFR 463.14 (NSPS)pH ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Contact Cooling and Heating Water Subcategory existing sources (BCT) table: Subpart A [Contact cooling and heating water] | 40 CFR 463.17 (BCT)pH ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Cleaning Water Subcategory existing sources (BPT) table: Subpart B [Cleaning water] | 40 CFR 463.22 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Cleaning Water Subcategory new sources (NSPS) Any new source subject to this subpart must achieve performance standards ( i.e. , mass of pollutant discharged) calculated by multiplying the average process water usage flow rate for cleaning processes at a new source times the following pollutant concentrations: table: Subpart B [Cleaning water] | 40 CFR 463.24 (NSPS)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Finishing Water Subcategory existing sources (BPT) table: Subpart C [Finishing water] | 40 CFR 463.32 (BPT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Finishing Water Subcategory new sources (NSPS) (b) Any new source subject to this subpart must achieve performance standards ( i.e. , mass of pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the finishing water processes at a new source times the following pollutant concentrations: table: Subpart C [Finishing water] | 40 CFR 463.34 (NSPS)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 7.0 to 10.00 pH units | (a) Casting Cleaning Operations. table: BPT Effluent Limitations | 40 CFR 464.12 (BPT)pH ( 1 ) ( 1 ) |
| 7.0 to 10.0 pH units | (a) Casting Cleaning Operations. | 40 CFR 464.12 (BPT)pH ( 3 ) ( 3 ) ( 3 ) |
| 7.0 to 10.0 pH units | (b) Casting Quench Operations. table: BPT Effluent Limitations | 40 CFR 464.12 (BPT)pH ( 1 ) ( 1 ) |
| 7.0 to 10.0 pH units | (b) Casting Quench Operations. | 40 CFR 464.12 (BPT)pH ( 3 ) ( 3 ) ( 3 ) |
| 7.0 to 10.0 pH units | (c) Die Casting Operations. | as above |
All 111 rows from 40 CFR Part 464 — Metal molding and casting point source category
| Value | Applies when | Cite |
|---|---|---|
| 7.5 to 10.0 pH units | the discharge is of the Subpart A—Steel Basis Material Subcategory existing sources (BPT) table: Subpart A | 40 CFR 465.11 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart A—Steel Basis Material Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: table: Subpart A | 40 CFR 465.13 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart B—Galvanized Basis Material Subcategory existing sources (BPT) table: Subpart B | 40 CFR 465.21 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart B—Galvanized Basis Material Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a new source subject to the provisions of this subpart: table: Subpart B | 40 CFR 465.23 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart C—Aluminum Basis Material Subcategory existing sources (BPT) table: Subpart C | 40 CFR 465.31 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart C—Aluminum Basis Material Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart. table: Subpart C | 40 CFR 465.33 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.0 to 10 pH units | the discharge is of the Subpart D—Canmaking Subcategory existing sources (BPT) table: Subpart D—BPT Effluent Limitations | 40 CFR 465.41 (BPT)pH ( 1 ) ( 1 ) |
| 7.0 to 10 pH units | the discharge is of the Subpart D—Canmaking Subcategory new sources (NSPS) The following standards of performance establish the quantity of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: table: Subpart D—NSPS | 40 CFR 465.43 (NSPS)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 7.5 to 10.0 pH units | the discharge is of the Subpart A—Steel Basis Material Subcategory existing sources (BPT) table: Subpart A—BPT Effluent Limitations column: Metal preparation | 40 CFR 466.11 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart A—Steel Basis Material Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards: table: Subpart A—NSPS column: Metal preparation | 40 CFR 466.13 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart B—Cast Iron Basis Material Subcategory existing sources (BPT) (b) The discharge of process wasterwater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below: table: Subpart B—BPT Effluent Limitations | 40 CFR 466.21 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart B—Cast Iron Basis Material Subcategory new sources (NSPS) (b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below: table: Subpart B—NSPS | 40 CFR 466.23 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart C—Aluminum Basis Material Subcategory existing sources (BPT) table: Subpart C—BPT Effluent Limitations column: Metal preparation | 40 CFR 466.31 (BPT)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart C—Aluminum Basis Material Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards: table: Subpart C—NSPS column: Metal preparation | 40 CFR 466.33 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | the discharge is of the Subpart D—Copper Basis Material Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards: table: Subpart D—NSPS column: Metal preparation | 40 CFR 466.43 (NSPS)pH ( 1 ) ( 1 ) ( 1 ) ( 1 ) |
| Value | Cite |
|---|---|
| 7.0 to 10 pH units | 40 CFR 467.12 (BPT)pH ( 1 ) ( 1 ) |
| 7.0 to 10 pH units | as above |
| 7.0 to 10 pH units | as above |
| 7.0 to 10 pH units | as above |
| 7.0 to 10 pH units | as above |
All 76 rows from 40 CFR Part 467 — Aluminum forming point source category
| Value | Applies when | Cite |
|---|---|---|
| 7.5 to 10.0 pH units | (a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)pH ( 1 ) ( 1 ) |
| 7.5 to 10.0 pH units | (b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations. | as above |
| 7.5 to 10.0 pH units | (c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations. | as above |
| 7.5 to 10.0 pH units | (d) Subpart A—Solution Heat Treatment BPT Effluent Limitations. | as above |
| 7.5 to 10.0 pH units | (e) Subpart A—Extrusion Heat Treatment BPT Effluent Limitations. | as above |
All 33 rows from 40 CFR Part 468 — Copper forming point source category
| Value | Applies when | Cite |
|---|---|---|
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Semiconductor Subcategory existing sources (BPT) table: Subpart A—Semiconductor BPT Effluent Limitations | 40 CFR 469.14 (BPT)pH ( 3 ) ( 3 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Semiconductor Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS). table: Subpart A—Semiconductor NSPS Effluent Limitations | 40 CFR 469.17 (NSPS)pH ( 2 ) ( 3 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart A—Semiconductor Subcategory existing sources (BCT) table: Subpart A—Semiconductor BCT Effluent Limitations | 40 CFR 469.19 (BCT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Electronic Crystals Subcategory existing sources (BPT) table: Subpart B—Electronic Crystals BPT Effluent Limitations | 40 CFR 469.24 (BPT)pH ( 4 ) ( 4 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Electronic Crystals Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart B—Electronic Crystals NSPS Effluent Limitations | 40 CFR 469.27 (NSPS)pH ( 4 ) ( 4 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart B—Electronic Crystals Subcategory existing sources (BCT) table: Subpart B—Electronic Crystals BCT Effluent Limitations | 40 CFR 469.29 (BCT)pH ( 1 ) ( 1 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart C—Cathode Ray Tube Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 469.35 (NSPS)pH ( 2 ) ( 2 ) |
| 6.0 to 9.0 pH units | the discharge is of the Subpart D—Luminescent Materials Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 469.42 (NSPS)pH ( 1 ) ( 1 ) |
| Value | Applies when | Cite |
|---|---|---|
| 7.5 to 10.0 pH units | (a) Rolling spent emulsions. | 40 CFR 471.11 (BPT)pH ( 1 ) |
| 7.5 to 10.0 pH units | (b) Rolling spent soap solutions. | as above |
| 7.5 to 10.0 pH units | (d) Drawing spent emulsions. | as above |
| 7.5 to 10.0 pH units | (e) Drawing spent soap solutions. | as above |
| 7.5 to 10.0 pH units | (f) Extrusion press and solution heat treatment contact cooling water. | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
This page shows 217 of 1,786 rows: every instrument, each with its first 5 rows or all of them. All 1,786 as JSON, 200 a page.
17 NPDES permits in Oregon went over a ph limit in their last 12 months of reports: the list as JSON.
69 instruments we hold for Oregon (US-OR) and United States, for 17 names matching “ph” (each in the JSON). 48 have a row, in the tables above; 21 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the ph limits in Oregon? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=ph&place=US-OR; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.