TSS in Nevada (US-NV): 40 CFR Part 419 — Petroleum refining point source category

56 rows for tss in this instrument. Every instrument for tss in Nevada

United States (US): 56 rows

Effluent: 56 rows

40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05 · 56 limits
Every row: discharge to surface water
ValueStatisticApplies whenCite
15.8 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
40 CFR 419.12 (BPT)
TSS 15.8 10.1
10.1 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.033 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.12 (BPT)
TSS 0.033 0.021
0.021 kilograms per cubic meter of flowmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.12 (BPT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
15.8 Kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
40 CFR 419.14 (BCT)
TSS 15.8 10.1
10.1 Kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.033 kilograms per m³ of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best conventional pollutant control technology by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation allowed fo…
40 CFR 419.14 (BCT)
TSS 0.033 0.021
0.021 kilograms per m³ of flowmonthly averageas aboveas above
33. kilograms per 1,000 (m³ of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.14 (BCT)
TSS 33. 21.
21. kilograms per 1,000 (m³ of flowmonthly averageas aboveas above
8.3 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.16 (NSPS)
TSS 8.3 4.9
4.9 kilograms per cubic meter of flowmonthly averageas aboveas above
0.033 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.16 (NSPS)
TSS 0.033 0.021
0.021 kilograms per cubic meter of flowmonthly averageas aboveas above
19.5 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
40 CFR 419.22 (BPT)
TSS 19.5 12.6
12.6 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.22 (BPT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
19.5 kilograms per 1,000 (m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.24 (BCT)
TSS 19.5 12.6
12.6 kilograms per 1,000 (m³ of feedstockmonthly averageas aboveas above
33 kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.24 (BCT)
TSS 33 21
21 kilograms per 1,000 m³ of flowmonthly averageas aboveas above
11.3 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.26 (NSPS)
TSS 11.3 7.2
7.2 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
23.4 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
40 CFR 419.32 (BPT)
TSS 23.4 14.8
14.8 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.32 (BPT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
23.4 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.34 (BCT)
TSS 23.4 14.8
14.8 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.34 (BCT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
14.9 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.36 (NSPS)
TSS 14.9 9.5
9.5 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
35.6 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
40 CFR 419.42 (BPT)
TSS 35.6 22.7
22.7 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.42 (BPT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
35.6 Metric units (kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BCT)
(a) Any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.44 (BCT)
TSS 35.6 22.7
22.7 Metric units (kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. Metric unit (kilograms per 1,000 m³ of flow)daily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.44 (BCT)
TSS 33. 21.
21. Metric unit (kilograms per 1,000 m³ of flow)monthly averageas aboveas above
23.4 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart D—Lube Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.46 (NSPS)
TSS 23.4 14.9
14.9 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
37.3 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
40 CFR 419.52 (BPT)
TSS 37.3 23.7
23.7 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.52 (BPT)
TSS 33. 21.
21. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
37.3 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BCT)
(a) Any existing point subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):
40 CFR 419.54 (BCT)
TSS 37.3 23.7
23.7 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
33. kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BCT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer …
40 CFR 419.54 (BCT)
TSS 33. 21.
21. kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
28.1 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.56 (NSPS)
TSS 28.1 17.9
17.9 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.