Passage Data · Cited limits by place · Use it from your AI

pH in Nevada (US-NV): 40 CFR Part 436 — Mineral mining and processing point source category

10 rows for ph in this instrument. Every instrument for ph in Nevada

United States (US): 10 rows

Effluent: 10 rows

40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05 · 10 limits
Every row: discharge to surface water
ValueApplies whenCite
6.0 to 9.0 pH unitsthe discharge is of the Subpart B—Crushed Stone Subcategory
existing sources (BPT)
(1) Discharges of process generated waste water pollutants from facilities that recycle waste water for use in processing shall not exceed the following limitations:
40 CFR 436.22 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart B—Crushed Stone Subcategory
existing sources (BPT)
(2) Mine dewatering discharges shall not exceed the following limitations:
as above
6.0 to 9.0 pH unitsthe discharge is of the Subpart C—Construction Sand and Gravel Subcategory
existing sources (BPT)
(1) Discharges of process generated waste water pollutants from facilities that recycle waste water for use in processing shall not exceed the following limitations:
40 CFR 436.32 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart C—Construction Sand and Gravel Subcategory
existing sources (BPT)
(2) Mine dewatering discharges shall not exceed the following limitations:
as above
6.0 to 9.0 pH unitsthe discharge is of the Subpart D—Industrial Sand Subcategory
existing sources (BPT)
(1) With the exception of operation using HF flotation, discharges of process waste water pollutants from facilities that recycle waste water, for use in the processing shall not exceed the following limitations:
40 CFR 436.42 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart D—Industrial Sand Subcategory
existing sources (BPT)
(3) Process generated waste water from facilities employing HF flotation shall not exceed the following limitations:
table: [Metric units, kg/kkg of total product; English units, lb/1,000 lb of total product]
as above
6.0 to 9.0 pH unitsthe discharge is of the Subpart D—Industrial Sand Subcategory
existing sources (BPT)
(4) Mine dewatering discharges shall not exceed the following limitations:
as above
6.0 to 9.0 pH unitsthe discharge is of the Subpart R—Phosphate Rock Subcategory
existing sources (BPT)
(1) Discharges of process generated waste water and mine dewatering discharges, shall not exceed the following limitations:
40 CFR 436.182 (BPT)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart R—Phosphate Rock Subcategory
new sources (NSPS)
(1) Discharges of process generated waste water and mine dewatering discharges, shall not exceed the following limitations:
40 CFR 436.185 (NSPS)
pH ( 1 ) ( 1 )
6.0 to 9.0 pH unitsthe discharge is of the Subpart AL—Graphite Subcategory
existing sources (BPT)
40 CFR 436.382 (BPT)
pH ( 1 ) ( 1 )

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.