Passage Data · Cited limits by place · Use it from your AI
612 cited rows from 18 instruments, Nevada's own first. Not covered: a permit's own limits, or rules outside the 70 instruments we hold for Nevada (US-NV) and United States. Everything held for Nevada
Nevada: surface water 5 · United States: drinking water 3, surface water 5, effluent 592, leachate 2, soil 4, product 1
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 5 µg/L | — | waters with the beneficial use municipal or domestic supply (the uses each water carries are set in NAC 445A.123 to 445A.2234; site-specific standards for toxic materials take precedence, subsection 1) | NAC 445A.1236 subsection 2 · p. 81Cadmium 5b - 10d 50d |
| 10 µg/L | — | waters with the beneficial use irrigation (the uses each water carries are set in NAC 445A.123 to 445A.2234; site-specific standards for toxic materials take precedence, subsection 1) | as above |
| 50 µg/L | — | waters with the beneficial use watering of livestock (the uses each water carries are set in NAC 445A.123 to 445A.2234; site-specific standards for toxic materials take precedence, subsection 1) | as above |
| (1.136672-{ln(hardness)(0.041838)})*e^(0.9789{ln(hardness)} - 3.866) µg/L | 1-hour average | waters with the beneficial use aquatic life (the uses each water carries are set in NAC 445A.123 to 445A.2234; site-specific standards for toxic materials take precedence, subsection 1) hardness-dependent: the cell's equation of the receiving water's hardness (mg/L as CaCO3; 'e' the base of the natural logarithm, footnote (2)); printed, not evaluated | NAC 445A.1236 subsection 2 · p. 81Cadmium 5b - 10d 50d 1-hour average - (1.136672-{ln(hardness)(0.041838)})*e - - (0.9789{ln(hardness)} - 3.866) h,(4) |
| (1.101672-{ln(hardness)(0.041838)})*e^(0.7977{ln(hardness)} - 3.909) µg/L | 4-day average | as above | NAC 445A.1236 subsection 2 · p. 81Cadmium 5b - 10d 50d 1-hour average - (1.136672-{ln(hardness)(0.041838)})*e - - (0.9789{ln(hardness)} - 3.866) h,(4) 96-hour average - (1.101672-{ln(hardness)(0.041838)})*e - - (0.7977{ln(hardness)} - 3.909) h,(4) |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Kind | Applies when | Cite |
|---|---|---|---|
| 0.005 mg/l | guideline | 40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals. | 141.51, 141.62 |
| 0.005 mg/l | limit | 40 CFR 141.2: Maximum contaminant level means the maximum permissible level of a contaminant in water which is delivered to any user of a public water system. | as above |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Cadmium (Water) | 1.8 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Value | Applies when | Cite |
|---|---|---|
| 1.8 µg/L | receiving water: freshwater Freshwater CMC (acute): criterion maximum concentration, acute normalized to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness) | National Recommended Aquatic Life Criteria tableCadmium (P) 7440439 1.8 vacated 33 7.9 2016 |
| exp{0.9789 [ln(hardness)] + -3.866} × CF, CF = 1.136672-[( ln hardness)(0.041838)] µg/L | receiving water: freshwater Freshwater CMC (acute), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here | Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-DependentCadmium 3 0.9789 -3.866 — — 1.136672-[( ln hardness)(0.041838)] — |
| vacated | receiving water: freshwater Freshwater CCC (chronic): criterion continuous concentration, chronic | National Recommended Aquatic Life Criteria tableCadmium (P) 7440439 1.8 vacated 33 7.9 2016 |
| 33 µg/L | receiving water: marine Saltwater CMC (acute): criterion maximum concentration, acute | as above |
| 7.9 µg/L | receiving water: marine Saltwater CCC (chronic): criterion continuous concentration, chronic | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cd | 1.2 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)Cd 1.2 .7 |
| Cd | .7 mg/L | — | as above | as above |
| Cd | 1.2 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | as above |
| Cd | .7 mg/L | — | as above | as above |
| Cd | 47 mg/sq m-Operation | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.14 (PSES)Cd 47 29 |
| Cd | 29 mg/sq m-Operation | — | as above | as above |
| Cd | 1.2 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)Cd 1.2 .7 |
| Cd | .7 mg/L | — | as above | as above |
| Cd | 1.2 mg/L | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)Cd 1.2 .7 |
| Cd | .7 mg/L | — | as above | as above |
All 56 rows from 40 CFR Part 413 — Electroplating point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cadmium (T) | 0.078 Kg/kkg (or pounds per/1,000 lb) of product | daily maximum | discharge to surface water existing sources (BPT) table: Subpart BL—Cadmium Pigments | 40 CFR 415.642 (BPT)Cadmium (T) 0.078 0.026 |
| Cadmium (T) | 0.026 Kg/kkg (or pounds per/1,000 lb) of product | monthly average | as above | as above |
| Cadmium (T) | 0.84 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Subpart BL—Cadmium Pigments | 40 CFR 415.644 (PSES)Cadmium (T) 0.84 0.28 |
| Cadmium (T) | 0.28 mg/L | monthly average | as above | as above |
| Cadmium (T) | 0.84 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Subpart BL—Cadmium Salts | as above |
| Cadmium (T) | 0.28 mg/L | monthly average | as above | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cadmium | 0.00006 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product) | daily maximum | the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory existing sources (BPT) table: Effluent Limitations | 40 CFR 421.52 (BPT)Cadmium 0.00006 0.00003 |
| Cadmium | 0.00003 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product) | monthly average | as above | as above |
| Cd | 0.008 (1) English Units (pounds per 1,000 pounds of product) | daily maximum | the discharge is of the Subpart H—Primary Zinc Subcategory existing sources (BPT) table: Effluent Limitations | 40 CFR 421.82 (BPT)Cd 0.008 0.004 |
| Cd | 0.004 (1) English Units (pounds per 1,000 pounds of product) | monthly average | as above | as above |
| Cadmium | .334 mg/kg (pounds per million pounds) of zinc reduced | daily maximum | the discharge is of the Subpart H—Primary Zinc Subcategory existing sources (BAT) (a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control. table: BAT Effluent Limitations | 40 CFR 421.83 (BAT)Cadmium .334 .134 |
| Cadmium | .134 mg/kg (pounds per million pounds) of zinc reduced | monthly average | as above | as above |
| Cadmium | .180 mg/kg (pounds per million pounds) of concentrate leached | daily maximum | the discharge is of the Subpart H—Primary Zinc Subcategory existing sources (BAT) (b) Subpart H—Preleach of Zinc Concentrates. table: BAT Effluent Limitations | 40 CFR 421.83 (BAT)Cadmium .180 .072 |
| Cadmium | .072 mg/kg (pounds per million pounds) of concentrate leached | monthly average | as above | as above |
| Cadmium | .000 mg/kg (pounds per million pounds) of zinc processed through leaching | daily maximum | the discharge is of the Subpart H—Primary Zinc Subcategory existing sources (BAT) (c) Subpart H—Leaching Wet Air Pollution Control. table: BAT Effluent Limitations | 40 CFR 421.83 (BAT)Cadmium .000 .000 |
| Cadmium | .000 mg/kg (pounds per million pounds) of zinc processed through leaching | monthly average | as above | as above |
All 88 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cadmium (T) | 0.69 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: BPT Effluent Limitations | 40 CFR 433.13 (BPT)Cadmium (T) 0.69 0.26 |
| Cadmium (T) | 0.26 mg/L | monthly average | as above | as above |
| Cadmium (T) | 0.69 mg/L | daily maximum | discharge to surface water existing sources (BAT) table: BAT Effluent Limitations | 40 CFR 433.14 (BAT)Cadmium (T) 0.69 0.26 |
| Cadmium (T) | 0.26 mg/L | monthly average | as above | as above |
| Cadmium (T) | 0.69 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers | 40 CFR 433.15 (PSES)Cadmium (T) 0.69 0.26 |
| Cadmium (T) | 0.26 mg/L | monthly average | as above | as above |
| Cadmium (T) | 0.11 mg/L | daily maximum | discharge to surface water new sources (NSPS) (a) Any new source subject to this subpart must achieve the following performance standards: table: NSPS | 40 CFR 433.16 (NSPS)Cadmium (T) 0.11 0.07 |
| Cadmium (T) | 0.07 mg/L | monthly average | as above | as above |
| Cadmium (T) | 0.11 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) table: PSNS | 40 CFR 433.17 (PSNS)Cadmium (T) 0.11 0.07 |
| Cadmium (T) | 0.07 mg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.474 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)Cadmium 0.474 0.0962 |
| 0.0962 mg/L | monthly average | as above | as above |
| 0.782 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)Cadmium 0.782 0.163 |
| 0.163 mg/L | monthly average | as above | as above |
| 0.0172 mg/L | daily maximum | the discharge is of the Subpart B—Oils Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.21 (BPT)Cadmium 0.0172 0.0102 |
| 0.0102 mg/L | monthly average | as above | as above |
| 0.0172 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | 40 CFR 437.42 (BPT)Cadmium 0.0172 0.0102 |
| 0.0102 mg/L | monthly average | as above | as above |
| 0.0172 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | as above |
| 0.0102 mg/L | monthly average | as above | as above |
All 34 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cd | .10 mg/L | daily maximum | existing sources (BPT) (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed: | 40 CFR 440.62 (BPT)Cd .10 .05 |
| Cd | .05 mg/L | monthly average | as above | as above |
| Cd | .10 mg/L | daily maximum | existing sources (BPT) (c) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by purely physical methods including ore crushing, washing, jigging, heavy media separation, and magnetic and electrostatic separation shall not exceed: | as above |
| Cd | .05 mg/L | monthly average | as above | as above |
| Cd | .10 mg/L | daily maximum | existing sources (BPT) (d) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by froth flotation methods shall not exceed: | as above |
| Cd | .05 mg/L | monthly average | as above | as above |
| Cd | 0.10 mg/L | daily maximum | existing sources (BAT) (a) The concentration of pollutants discharged in mine drainage from tungsten mines shall not exceed: | 40 CFR 440.63 (BAT)Cd 0.10 0.05 |
| Cd | 0.05 mg/L | monthly average | as above | as above |
| Cd | 0.10 mg/L | daily maximum | existing sources (BAT) (b) The concentration of pollutants discharged from mills shall not exceed: | as above |
| Cd | 0.05 mg/L | monthly average | as above | as above |
All 44 rows from 40 CFR Part 440 — Ore mining and dressing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.020 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: Table—Effluent Limitations | 40 CFR 442.31 (BPT)Cadmium 0.020 |
| 0.020 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Table—Pretreatment Standards | 40 CFR 442.35 (PSES)Cadmium 0.020 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 71 µg/L | daily maximum | discharge to surface water existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)Cadmium 71 26 |
| 26 µg/L | monthly average | as above | as above |
| 71 µg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Pretreatment Standards 1 | 40 CFR 444.16 (PSES)Cadmium 71 26 |
| 26 µg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.92 mg/kg of cadmium | daily maximum | (1) Subpart A—Pasted and Pressed Powder Anodes. | 40 CFR 461.11 (BPT)Cadmium 0.92 0.41 |
| 0.41 mg/kg of cadmium | monthly average | as above | as above |
| 237.0 mg/kg of cadmium | daily maximum | (2) Subpart A—Electrodeposited Anodes. | 40 CFR 461.11 (BPT)Cadmium 237.0 104.6 |
| 104.6 mg/kg of cadmium | monthly average | as above | as above |
| 339.3 mg/kg of cadmium | daily maximum | (3) Subpart A—Impregnated Anodes. | 40 CFR 461.11 (BPT)Cadmium 339.3 149.7 |
| 149.7 mg/kg of cadmium | monthly average | as above | as above |
| 193.5 mg/kg of nickel applied | daily maximum | (4) Subpart A—Nickel Electrodeposited Cathodes. | 40 CFR 461.11 (BPT)Cadmium 193.5 85.4 |
| 85.4 mg/kg of nickel applied | monthly average | as above | as above |
| 557.6 mg/kg of nickel applied | daily maximum | (5) Subpart A—Nickel Impregnated Cathodes. | 40 CFR 461.11 (BPT)Cadmium 557.6 246.0 |
| 246.0 mg/kg of nickel applied | monthly average | as above | as above |
All 92 rows from 40 CFR Part 461 — Battery manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.06 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart C—Cathode Ray Tube Subcategory existing sources (PSES) | 40 CFR 469.34 (PSES)Cadmium 0.06 0.03 |
| 0.03 mg/L | monthly average | as above | as above |
| 0.06 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart C—Cathode Ray Tube Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 469.35 (NSPS)Cadmium 0.06 0.03 |
| 0.03 mg/L | monthly average | as above | as above |
| 0.06 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart C—Cathode Ray Tube Subcategory new sources (PSNS) | 40 CFR 469.36 (PSNS)Cadmium 0.06 0.03 |
| 0.03 mg/L | monthly average | as above | as above |
| 0.55 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart D—Luminescent Materials Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 469.42 (NSPS)Cadmium 0.55 0.26 |
| 0.26 mg/L | monthly average | as above | as above |
| 0.55 mg/L | — | discharge to a sewer (pretreatment) the discharge is of the Subpart D—Luminescent Materials Subcategory new sources (PSNS) column: For any 1 day | 40 CFR 469.43 (PSNS)Cadmium 0.55 0.26 |
| 0.26 mg/L | monthly average | discharge to a sewer (pretreatment) the discharge is of the Subpart D—Luminescent Materials Subcategory new sources (PSNS) | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.016 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | daily maximum | (d) Drawing spent emulsions. | 40 CFR 471.41 (BPT)Cadmium 0.016 0.007 |
| 0.007 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | monthly average | as above | as above |
| 0.001 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutions | daily maximum | (e) Drawing spent soap solutions. | 40 CFR 471.41 (BPT)Cadmium 0.001 0.0005 |
| 0.0005 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutions | monthly average | as above | as above |
| 2.27 mg/off-kg (pounds per million off-pounds) of precious metals powder wet atomized | daily maximum | (f) Metal powder production wet atomization wastewater. | 40 CFR 471.41 (BPT)Cadmium 2.27 1.00 |
| 1.00 mg/off-kg (pounds per million off-pounds) of precious metals powder wet atomized | monthly average | as above | as above |
| 1.42 mg/off-kg (pounds per million off-pounds) of extruded precious metals heat treated | daily maximum | (g) Heat treatment contact cooling water. | 40 CFR 471.41 (BPT)Cadmium 1.42 0.626 |
| 0.626 mg/off-kg (pounds per million off-pounds) of extruded precious metals heat treated | monthly average | as above | as above |
| 3.50 mg/off-kg (pounds per million off-pounds) of precious metals cast by the semi-continuous or continuous method | daily maximum | (h) Semi-continuous or continuous casting contact cooling water. | 40 CFR 471.41 (BPT)Cadmium 3.50 1.55 |
| 1.55 mg/off-kg (pounds per million off-pounds) of precious metals cast by the semi-continuous or continuous method | monthly average | as above | as above |
| Value | Applies when | Cite |
|---|---|---|
| 1.0 mg/L | (a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section. | 40 CFR 261.24, Table 1D006 Cadmium 7440-43-9 1.0 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.11 mg/L TCLP | instantaneous | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standardCadmium 7440-43-9 0.69 0.11 mg/l TCLP |
| Parameter | Value | Kind | Applies when | Cite |
|---|---|---|---|---|
| Cadmium (Diet) | 7.1 mg/kg | guideline | Resident Soil (mg/kg) | source |
| Cadmium (Diet) | 100 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
| Cadmium (Water) | 0.14 mg/kg | guideline | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Cadmium (Water) | 0.38 mg/kg | reference value (not a limit) | Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.69 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standardCadmium 7440-43-9 0.69 0.11 mg/l TCLP |
This page shows 112 of 612 rows: every instrument, each with its first 10 rows or all of them. All 612 as JSON, 200 a page.
70 instruments we hold for Nevada (US-NV) and United States, for 13 names matching “cadmium” (each in the JSON). 18 have a row, in the tables above; 52 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the cadmium limits in Nevada? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=cadmium&place=US-NV; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI