Passage Data · Cited limits by place · Use it from your AI

COD in North Carolina (US-NC): 40 CFR Part 419 — Petroleum refining point source category

56 rows for cod in this instrument. Every instrument for cod in North Carolina

United States (US): 56 rows

Effluent: 56 rows

40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05 · 56 limits
Every row: discharge to surface water
ValueStatisticApplies whenCite
117.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
40 CFR 419.12 (BPT)
COD 1 117.0 60.3
60.3 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.47 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.12 (BPT)
COD 1 0.47 0.24
0.24 kilograms per cubic meter of flowmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.12 (BPT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
117 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BAT)
40 CFR 419.13 (BAT)
COD 1 117 60.3
60.3 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
0.47 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BAT)
(d) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph, attributable to ballast, which may be discharged after the application of best available technology economically achievable by a point source subject to the provisions of this subpart. These allocations are in addition to the discharge allowed by paragraph (b) of…
40 CFR 419.13 (BAT)
COD 1 0.47 0.24
0.24 kilograms per cubic meter of flowmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
existing sources (BAT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …
40 CFR 419.13 (BAT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
61.0 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.16 (NSPS)
COD 1 61.0 32
32 kilograms per cubic meter of flowmonthly averageas aboveas above
0.47 kilograms per cubic meter of flowdaily maximumthe discharge is of the Subpart A—Topping Subcategory
new sources (NSPS)
(c) The following allocations constitute the quantity and quality of pollutants or pollutant properties controlled by this paragraph and attributable to ballast, which may be discharged after the application of best practicable control technology currently available, by a point source subject to this subpart, in addition to the discharge allowed by paragraph (b) of this section. The allocation …
40 CFR 419.16 (NSPS)
COD 1 0.47 0.24
0.24 kilograms per cubic meter of flowmonthly averageas aboveas above
210.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
40 CFR 419.22 (BPT)
COD 1 210.0 109
109 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.22 (BPT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
210 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BAT)
40 CFR 419.23 (BAT)
COD 1 210 109
109 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
existing sources (BAT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …
40 CFR 419.23 (BAT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
118.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart B—Cracking Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.26 (NSPS)
COD 1 118.0 61
61 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
210.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
40 CFR 419.32 (BPT)
COD 1 210.0 109.0
109.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.32 (BPT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
210.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BAT)
40 CFR 419.33 (BAT)
COD 1 210.0 109.0
109.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
existing sources (BAT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …
40 CFR 419.33 (BAT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
133.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart C—Petrochemical Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.36 (NSPS)
COD 1 133.0 69.0
69.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
40 CFR 419.42 (BPT)
COD 1 360.0 187.0
187.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.42 (BPT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
360.0 Metric units (kilograms perdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BAT)
40 CFR 419.43 (BAT)
COD 1 360.0 187.0
187.0 Metric units (kilograms permonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart D—Lube Subcategory
existing sources (BAT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …
40 CFR 419.43 (BAT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
245.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart D—Lube Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.46 (NSPS)
COD 1 245.0 126.0
126.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
388.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
40 CFR 419.52 (BPT)
COD 1 388.0 198.0
198.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BPT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…
40 CFR 419.52 (BPT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
388.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BAT)
40 CFR 419.53 (BAT)
COD 1 388.0 198.0
198.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above
360. kilograms per 1,000 m³ of flowdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
existing sources (BAT)
(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …
40 CFR 419.53 (BAT)
COD 1 360. 180.
180. kilograms per 1,000 m³ of flowmonthly averageas aboveas above
295.0 kilograms per 1,000 m³ of feedstockdaily maximumthe discharge is of the Subpart E—Integrated Subcategory
new sources (NSPS)
(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 419.56 (NSPS)
COD 1 295.0 152.0
152.0 kilograms per 1,000 m³ of feedstockmonthly averageas aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.