Passage Data · Cited limits by place · Use it from your AI
42 cited rows from 1 instrument, North Carolina's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for North Carolina (US-NC) and United States. Everything held for North Carolina
The one instrument we hold for North Carolina (US-NC) has no row for cn, t. The rows below are from the place above it, which we search too.
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.9 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)CN, T 1.9 1.0 |
| 1.0 mg/L | — | as above | as above |
| 74 mg/sq m-Operation | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.14 (PSES)CN, T 74 39 |
| 39 mg/sq m-Operation | — | as above | as above |
| 1.9 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under… table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)CN, T 1.9 1.0 |
| 1.0 mg/L | — | as above | as above |
| 1.9 mg/L | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)CN, T 1.9 1.0 |
| 1.0 mg/L | — | as above | as above |
| 74 mg/sq m-Operation | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory (d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.24 (PSES)CN, T 74 39 |
| 39 mg/sq m-Operation | — | as above | as above |
All 42 rows from 40 CFR Part 413 — Electroplating point source category
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
This page shows 10 of 42 rows: every instrument, each with its first 10 rows or all of them. All 42 as JSON, 200 a page.
69 instruments we hold for North Carolina (US-NC) and United States, for 1 name matching “cn t” (each in the JSON). 1 has a row, in the tables above; 68 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the cn, t limits in North Carolina? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=cn%20t&place=US-NC; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI