Passage Data · Cited limits by place · Use it from your AI

Chromium (total) in Maryland (US-MD): 40 CFR Part 437 — The centralized waste treatment point source category

40 rows for chromium (total) in this instrument. Every instrument for chromium (total) in Maryland

United States (US): 40 rows

Effluent: 40 rows

40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05 · 40 limits
ParameterValueStatisticApplies whenCite
Chromium15.5 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart A—Metals Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.11 (BPT)
Chromium 15.5 3.07
Chromium3.07 mg/Lmonthly averageas aboveas above
Chromium0.167 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart A—Metals Treatment and Recovery
new sources (NSPS)
table: Performance Standards
40 CFR 437.14 (NSPS)
Chromium 0.167 0.0522
Chromium0.0522 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.21 (BPT)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium0.947 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (PSES)
table: Pretreatment Standards (PSES)
40 CFR 437.25 (PSES)
Chromium 0.947 0.487
Chromium0.487 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
40 CFR 437.42 (BPT)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
as above
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium15.5 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
40 CFR 437.42 (BPT)
Chromium 15.5 3.07
Chromium3.07 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (BPT)
(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:
table: BPT Limitations
40 CFR 437.42 (BPT)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium0.167 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
new sources (NSPS)
(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:
table: Performance Standards
40 CFR 437.45 (NSPS)
Chromium 0.167 0.0522
Chromium0.0522 mg/Lmonthly averageas aboveas above
Chromium0.167 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
new sources (NSPS)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following standards:
table: Performance Standards
as above
Chromium0.0522 mg/Lmonthly averageas aboveas above
Chromium0.167 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
new sources (NSPS)
(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:
table: Performance Standards
as above
Chromium0.0522 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to surface water
the discharge is of the Subpart D—Multiple Wastestreams
new sources (NSPS)
(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:
table: Performance Standards
40 CFR 437.45 (NSPS)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium0.947 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (PSES)
(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.46(a), and no later than [Insert date—three years after publication], any existing source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSES)
40 CFR 437.46 (PSES)
Chromium 0.947 0.487
Chromium0.487 mg/Lmonthly averageas aboveas above
Chromium0.947 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (PSES)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSES)
as above
Chromium0.487 mg/Lmonthly averageas aboveas above
Chromium15.5 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (PSES)
(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSES)
40 CFR 437.46 (PSES)
Chromium 15.5 3.07
Chromium3.07 mg/Lmonthly averageas aboveas above
Chromium0.947 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
existing sources (PSES)
(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSES)
40 CFR 437.46 (PSES)
Chromium 0.947 0.487
Chromium0.487 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
new sources (PSNS)
(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSNS)
40 CFR 437.47 (PSNS)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
new sources (PSNS)
(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSNS)
as above
Chromium0.323 mg/Lmonthly averageas aboveas above
Chromium15.5 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
new sources (PSNS)
(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSNS)
40 CFR 437.47 (PSNS)
Chromium 15.5 3.07
Chromium3.07 mg/Lmonthly averageas aboveas above
Chromium0.746 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Multiple Wastestreams
new sources (PSNS)
(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:
table: Pretreatment Standards (PSNS)
40 CFR 437.47 (PSNS)
Chromium 0.746 0.323
Chromium0.323 mg/Lmonthly averageas aboveas above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.