Passage Data · Cited limits by place · Use it from your AI
19 cited rows from 6 instruments, Maryland's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Maryland (US-MD) and United States. Everything held for Maryland
Maryland: surface water 2 · United States: drinking water 1, surface water 3, effluent 8, soil 3, product 2
| Value | Applies when | Cite |
|---|---|---|
| 0.61 a µg/L | human health for consumption of drinking water + organism (the table's column) | COMAR 26.08.02.03-2 G, Table 4 (human health, drinking water + organism)Acrylonitrile 107131 0.61 a 70 a |
| 70 a µg/L | human health for consumption of organism only (the table's column) | COMAR 26.08.02.03-2 G, Table 4 (human health, organism only)Acrylonitrile 107131 0.61 a 70 a |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Applies when | Cite |
|---|---|---|
| 0.052 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Value | Applies when | Cite |
|---|---|---|
| 0.061 µg/L | receiving water: freshwater consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns) | National Recommended Water Quality Criteria — Human Health Criteria TableAcrylonitrile (P) 107131 0.061 7.0 2015 |
| 7.0 µg/L | receiving water: freshwater consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt) | as above |
| 7.0 µg/L | receiving water: marine consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt) | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 242 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Acrylonitrile 242 96 |
| 242 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Acrylonitrile 242 96 |
| 96 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Acrylonitrile 242 96 |
| 96 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Acrylonitrile 242 96 |
| 232 µg/L | daily maximum | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Acrylonitrile 232 94 |
| 232 µg/L | daily maximum | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Acrylonitrile 232 94 |
| 94 µg/L | monthly average | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Acrylonitrile 232 94 |
| 94 µg/L | monthly average | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Acrylonitrile 232 94 |
| Value | Applies when | Cite |
|---|---|---|
| 0.25 mg/kg | Resident Soil (mg/kg) | source |
| 1.1 mg/kg | Industrial Soil (mg/kg) | as above |
| 1.1e-05 mg/kg | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Value | Statistic | Cite |
|---|---|---|
| 0.24 mg/L | composite sample | 40 CFR 268.48, Table UTS, Organic Constituents, wastewater standardAcrylonitrile 107-13-1 0.24 84 |
| 84 mg/kg | instantaneous | 40 CFR 268.48, Table UTS, Organic Constituents, nonwastewater standardAcrylonitrile 107-13-1 0.24 84 |
69 instruments we hold for Maryland (US-MD) and United States, for 11 names matching “acrylonitrile” (each in the JSON). 6 have a row, in the tables above; 63 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the acrylonitrile limits in Maryland? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=acrylonitrile&place=US-MD; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.