Passage Data · Cited limits by place · Use it from your AI
29 rows for oil in this instrument. Every instrument for oil in Massachusetts
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Oil | 1.40 q/kkg of product | daily maximum | discharge to surface water the discharge is of the Subpart E—Float Glass Manufacturing Subcategory existing sources (BPT) | 40 CFR 426.52 (BPT)Oil 1.40 1.40 |
| Oil | 1.40 q/kkg of product | monthly average | as above | as above |
| Oil | 1.40 g/kkg of product | daily maximum | discharge to surface water the discharge is of the Subpart E—Float Glass Manufacturing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 426.55 (NSPS)Oil 1.40 1 .40 |
| Oil | 0.64 q/sq m of product | daily maximum | discharge to surface water the discharge is of the Subpart F—Automotive Glass Tempering Subcategory existing sources (BPT) | 40 CFR 426.62 (BPT)Oil 0.64 .64 |
| Oil | .64 q/sq m of product | monthly average | as above | as above |
| Oil | 0.49 q/sq m of product | daily maximum | discharge to surface water the discharge is of the Subpart F—Automotive Glass Tempering Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 426.65 (NSPS)Oil 0.49 .49 |
| Oil | .49 q/sq m of product | monthly average | as above | as above |
| Oil | 1.76 q/sq m of product | daily maximum | discharge to surface water the discharge is of the Subpart G—Automotive Glass Laminating Subcategory existing sources (BPT) | 40 CFR 426.72 (BPT)Oil 1.76 1.76 |
| Oil | 1.76 q/sq m of product | monthly average | as above | as above |
| Oil | 1.76 q/sq m of product | daily maximum | discharge to surface water the discharge is of the Subpart G—Automotive Glass Laminating Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new point source subject to the provisions of this subpart: | 40 CFR 426.75 (NSPS)Oil 1.76 1.76 |
| Oil | 1.76 q/sq m of product | monthly average | as above | as above |
| Oil | 60.0 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart H—Glass Container Manufacturing Subcategory existing sources (BPT) | 40 CFR 426.82 (BPT)Oil 60.0 30.0 |
| Oil | 30.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil | 1.6 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart H—Glass Container Manufacturing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 426.85 (NSPS)Oil 1.6 0.8 |
| Oil | 0.8 g/kkg of furnace pull | monthly average | as above | as above |
| Oil (mineral) | 60.0 g/kkg of furnace pull | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart H—Glass Container Manufacturing Subcategory new sources (PSNS) Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject … | 40 CFR 426.86 (PSNS)Oil (mineral) 60.0 30.0 |
| Oil (mineral) | 30.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil | 260.0 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory existing sources (BPT) | 40 CFR 426.112 (BPT)Oil 260.0 130.0 |
| Oil | 130.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil | 260.0 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the… | 40 CFR 426.115 (NSPS)Oil 260.0 130.0 |
| Oil | 130.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil (mineral) | 260.0 g/kkg of furnace pull | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory new sources (PSNS) Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject … | 40 CFR 426.116 (PSNS)Oil (mineral) 260.0 130.0 |
| Oil (mineral) | 130.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil | 230.0 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart L—Incandescent Lamp Envelope Manufacturing Subcategory existing sources (BPT) (a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations. | 40 CFR 426.122 (BPT)Oil 230.0 115.0 |
| Oil | 115.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil | 90.0 g/kkg of furnace pull | daily maximum | discharge to surface water the discharge is of the Subpart L—Incandescent Lamp Envelope Manufacturing Subcategory new sources (NSPS) (a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations. | 40 CFR 426.125 (NSPS)Oil 90.0 45.0 |
| Oil | 45.0 g/kkg of furnace pull | monthly average | as above | as above |
| Oil (mineral) | 230.0 g/kkg of furnace pull | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart L—Incandescent Lamp Envelope Manufacturing Subcategory new sources (PSNS) Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject … | 40 CFR 426.126 (PSNS)Oil (mineral) 230.0 115.0 |
| Oil (mineral) | 115.0 g/kkg of furnace pull | monthly average | as above | as above |
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.