Passage Data · Cited limits by place · Use it from your AI
36 rows for oil & grease (alternate monitoring parameter) in this instrument. Every instrument for oil & grease (alternate monitoring parameter) in Louisiana
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart K—Poultry First Processing existing sources (BPT) table: Effluent Limitations [BPT] | 40 CFR 432.112 (BPT)O&G (as HEM) 14 8.0 |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart K—Poultry First Processing new sources (NSPS) (a) Facilities that slaughter no more than 100 million pounds per year (in units of LWK) must achieve the following performance standards: table: Performance Standards [NSPS] | 40 CFR 432.115 (NSPS)O&G (as HEM) 14 8.0 |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart K—Poultry First Processing new sources (NSPS) (b) Facilities that slaughter more than 100 million pounds per year (in units of LWK) must achieve the following performance standards: table: Performance Standards [NSPS] | as above |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart L—Poultry Further Processing existing sources (BPT) table: Effluent Limitations [BPT] | 40 CFR 432.122 (BPT)O&G (as HEM) 14 8.0 |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart L—Poultry Further Processing new sources (NSPS) (a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards: table: Performance Standards [NSPS] | 40 CFR 432.125 (NSPS)O&G (as HEM) 14 8.0 |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G (as HEM) | 14 mg/L | daily maximum | the discharge is of the Subpart L—Poultry Further Processing new sources (NSPS) (b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards: table: Effluent Limitations [NSPS] | as above |
| O&G (as HEM) | 8.0 mg/L | monthly average | as above | as above |
| O&G | 0.12 Pounds per 1000 lbs (or g/kg) LWK | daily maximum | the discharge is of the Subpart A—Simple Slaughterhouses existing sources (BPT) (1) In the case of process wastewater associated with the slaughtering of animals on-site or the processing of the carcasses of animals slaughtered on-site: table: Effluent Limitations [BPT] | 40 CFR 432.12 (BPT)O&G 4 0.12 0.06 |
| O&G | 0.06 Pounds per 1000 lbs (or g/kg) LWK | monthly average | as above | as above |
| O&G | 0.16 Pounds per 1000 lbs (or g/kg) LWK | daily maximum | the discharge is of the Subpart B—Complex Slaughterhouses existing sources (BPT) (1) In the case of process wastewater associated with the slaughtering of animals on-site or the processing of the carcasses of animals slaughtered on-site: table: Effluent Limitations [BPT] | 40 CFR 432.22 (BPT)O&G 4 0.16 0.08 |
| O&G | 0.08 Pounds per 1000 lbs (or g/kg) LWK | monthly average | as above | as above |
| O&G | 0.16 Pounds per 1000 lbs (or g/kg) LWK | daily maximum | the discharge is of the Subpart C—Low-processing Packinghouses existing sources (BPT) (1) In the case of process wastewater associated with slaughtering of animals on-site or the processing of the carcasses of animals slaughtered on-site: table: Effluent Limitations [BPT] | 40 CFR 432.32 (BPT)O&G 4 0.16 0.08 |
| O&G | 0.08 Pounds per 1000 lbs (or g/kg) LWK | monthly average | as above | as above |
| O&G | 0.26 Pounds per 1000 lbs (or g/kg) LWK | daily maximum | the discharge is of the Subpart D—High-Processing Packinghouse existing sources (BPT) (1) In the case of process wastewater associated with the slaughtering of animals on-site or the processing of the carcasses of animals slaughtered on-site: table: Effluent Limitations [BPT] | 40 CFR 432.42 (BPT)O&G 5 0.26 0.13 |
| O&G | 0.13 Pounds per 1000 lbs (or g/kg) LWK | monthly average | as above | as above |
| O&G | 1.0 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart E—Small Processors existing sources (BPT) table: Effluent Limitations [BPT] | 40 CFR 432.52 (BPT)O&G 3 1.0 0.5 |
| O&G | 0.5 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.5 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart E—Small Processors new sources (NSPS) Any source that is a new source subject to this subpart must achieve the following performance standards: table: Performance Standards (NSPS) | 40 CFR 432.55 (NSPS)O&G 3 0.5 0.25 |
| O&G | 0.25 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.012 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart F—Meat Cutters existing sources (BPT) (a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations: table: Effluent Limitations [BPT] | 40 CFR 432.62 (BPT)O&G 4 0.012 0.006 |
| O&G | 0.006 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.20 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart G—Sausage and Luncheon Meats Processors existing sources (BPT) (a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations: table: Effluent Limitations [BPT] | 40 CFR 432.72 (BPT)O&G 4 0.20 0.10 |
| O&G | 0.10 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.22 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart H—Ham Processors existing sources (BPT) (a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations: table: Effluent Limitations [BPT] | 40 CFR 432.82 (BPT)O&G 4 0.22 0.11 |
| O&G | 0.11 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.26 Pounds per 1000 lbs (or g/kg) of finished product | daily maximum | the discharge is of the Subpart I—Canned Meats Processors existing sources (BPT) (a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations: table: Effluent Limitations [BPT] | 40 CFR 432.92 (BPT)O&G 4 0.26 0.13 |
| O&G | 0.13 Pounds per 1000 lbs (or g/kg) of finished product | monthly average | as above | as above |
| O&G | 0.20 Pounds per 1000 lbs (or g/kg) of raw material (RM) | daily maximum | the discharge is of the Subpart J—Renderers existing sources (BPT) table: Effluent Limitations [BPT] | 40 CFR 432.102 (BPT)O&G 4 0.20 0.10 |
| O&G | 0.10 Pounds per 1000 lbs (or g/kg) of raw material (RM) | monthly average | as above | as above |
| O&G | 0.10 | daily maximum | the discharge is of the Subpart J—Renderers new sources (NSPS) table: Performance Standards [NSPS] | 40 CFR 432.105 (NSPS)O&G 1 4 0.10 0.05 |
| O&G | 0.05 | monthly average | as above | as above |
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.