Passage Data · Cited limits by place · Use it from your AI
7 cited rows from 4 instruments, Louisiana's own first. Not covered: a permit's own limits, or rules outside the 73 instruments we hold for Louisiana (US-LA) and United States. Everything held for Louisiana
Louisiana: ambient air 1, air emission 1 · United States: drinking water 1, soil 3, product 1
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.00 µg/m³ | annual average | a major source at or above the minimum emission rate demonstrates it (5109.B) | Table 51.2 Class IEthylene oxide 75-21-8 I 1.00 |
| Value | Applies when | Cite |
|---|---|---|
| 35.0 lb/yr | the source is a major source of toxic air pollutants (5103) | Table 51.1 Class IEthylene oxide 75-21-8 35.0 |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Applies when | Cite |
|---|---|---|
| 0.00067 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Value | Applies when | Cite |
|---|---|---|
| 0.002 mg/kg | Resident Soil (mg/kg) | source |
| 0.025 mg/kg | Industrial Soil (mg/kg) | as above |
| 1.4e-07 mg/kg | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.12 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Organic Constituents, wastewater standardEthylene oxide 75-21-8 0.12 NA |
73 instruments we hold for Louisiana (US-LA) and United States, for 8 names matching “ethylene oxide” (each in the JSON). 4 have a row, in the tables above; 69 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the ethylene oxide limits in Louisiana? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=ethylene%20oxide&place=US-LA; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.