Passage Data · Cited limits by place · Use it from your AI

pH in Kentucky (US-KY): 40 CFR Part 461 — Battery manufacturing point source category

52 rows for ph in this instrument. Every instrument for ph in Kentucky

United States (US): 52 rows

Effluent: 52 rows

40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05 · 52 limits
Every row: discharge to surface water
ValueApplies whenCite
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(1) Subpart A—Pasted and Pressed Powder Anodes.
table: BPT Effluent Limitations
40 CFR 461.11 (BPT)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(2) Subpart A—Electrodeposited Anodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(3) Subpart A—Impregnated Anodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(4) Subpart A—Nickel Electrodeposited Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(5) Subpart A—Nickel Impregnated Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(6) Subpart A—Miscellaneous Wastewater Streams.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(7) Subpart A—Cadmium Powder Production.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(8) Subpart A—Silver Powder Production.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(9) Subpart A—Cadmium Hydroxide Production.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
existing sources (BPT)
(10) Subpart A—Nickel Hydroxide Production.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(1) Subpart A—Electrodeposited Anodes—NSPS.
40 CFR 461.13 (NSPS)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(2) Subpart A—Impregnated Anodes—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(3) Subpart A—Nickel Electrodeposited Cathodes—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(4) Subpart A—Nickel Impregnated Cathodes—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(5) Subpart A—Miscellaneous Wastewater Streams—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(6) Subpart A—Cadmium Powder Production—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(7) Subpart A—Silver Powder Production—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(8) Subpart A—Cadmium Hydroxide Production—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart A—Cadmium Subcategory
new sources (NSPS)
(9) Subpart A—Nickel Hydroxide Production—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(1) Subpart C—Closed Formation—Double Fill, or Fill and Dump.
table: BPT Effluent Limitations
40 CFR 461.31 (BPT)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(2) Subpart C—Open Formation—Dehydrated.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(3) Subpart C—Open Formation—Wet.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(4) Subpart C—Plate Soak.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(5) Subpart C—Battery Wash (with Detergent).
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(6) Subpart C—Battery Wash (Water Only).
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(7) Subpart C—Direct Chill Lead Casting.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(8) Subpart C—Mold Release Formulation.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(9) Subpart C—Truck Wash.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(10) Subpart C—Laundry.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart C—Lead Subcategory
existing sources (BPT)
(11) Subpart C—Miscellaneous Wastewater Streams.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart D—Leclanche Subcategory
new sources (NSPS)
(1) Subpart D—Foliar Battery Miscellaneous Wash—NSPS.
40 CFR 461.43 (NSPS)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart E—Lithium Subcategory
new sources (NSPS)
(1) Subpart E—Lead Iodide Cathodes—NSPS.
40 CFR 461.53 (NSPS)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart E—Lithium Subcategory
new sources (NSPS)
(2) Subpart E—Iron Disulfide Cathodes—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart E—Lithium Subcategory
new sources (NSPS)
(3) Subpart E—Miscellaneous Wastewater Streams—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart E—Lithium Subcategory
new sources (NSPS)
(4) Subpart E—Air Scrubbers—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart F—Magnesium Subcategory
new sources (NSPS)
(1) Subpart F—Silver Chloride Cathodes—Chemically Reduced—NSPS.
40 CFR 461.63 (NSPS)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart F—Magnesium Subcategory
new sources (NSPS)
(2) Subpart F—Silver Chloride Cathodes—Electrolytic—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart F—Magnesium Subcategory
new sources (NSPS)
(3) Subpart F—Cell Testing—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart F—Magnesium Subcategory
new sources (NSPS)
(4) Subpart F—Floor and Equipment Wash—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart F—Magnesium Subcategory
new sources (NSPS)
(5) Subpart F—Air Scrubber—NSPS.
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(1) Subpart G—Wet Amalgamated Powder Anodes.
table: BPT Effluent Limitations
40 CFR 461.71 (BPT)
pH ( 1 ) ( 1 )
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(2) Subpart G—Gelled Amalgam Anodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(3) Subpart G—Zinc Oxide, Formed Anodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(4) Subpart G—Electrodeposited Anodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(5) Subpart G—Silver Powder, Formed Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(6) Subpart G—Silver Oxide Powder, Formed Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(7) Subpart G—Silver Peroxide Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(8) Subpart G—Nickel Impregnated Cathodes.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(9) Subpart G—Miscellaneous Wastewater Streams.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(10) Subpart G—Silver Etch.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(11) Subpart G—Silver Peroxide Production.
table: BPT Effluent Limitations
as above
7.5 to 10.0 pH unitsthe discharge is of the Subpart G—Zinc Subcategory
existing sources (BPT)
(12) Subpart G—Silver Powder Production.
table: BPT Effluent Limitations
as above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.