ValueStatisticApplies whenCite
56.46 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
40 CFR 466.11 (BPT)
Nickel 56.46 11.43 40.05 8.11
11.43 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
40.05 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
as above
8.11 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
56.50 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Metal preparation
40 CFR 466.12 (BAT)
Nickel 56.50 1.78 40.05 1.26
1.78 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Coating operation
as above
40.05 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Metal preparation
as above
1.26 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Coating operation
as above
12.0 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Metal preparation
40 CFR 466.13 (NSPS)
Nickel 12.0 1.51 6.3 0.79
1.51 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Coating operation
as above
6.3 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Metal preparation
as above
0.79 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart A—NSPS
column: Coating operation
as above
1.41 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (PSES)
table: Subpart A—PSES
40 CFR 466.14 (PSES)
Nickel 1.41 1.00
1.00 mg/Lmonthly averageas aboveas above
56.5 mg/m of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass effluent pretreatment standards the following equivalent mass standards are provided:
table: Subpart A—PSES
column: Metal preparation
40 CFR 466.14 (PSES)
Nickel 56.5 1.78 40.1 1.26
1.78 mg/m of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass effluent pretreatment standards the following equivalent mass standards are provided:
table: Subpart A—PSES
column: Coating operation
as above
40.1 mg/m of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass effluent pretreatment standards the following equivalent mass standards are provided:
table: Subpart A—PSES
column: Metal preparation
as above
1.26 mg/m of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass effluent pretreatment standards the following equivalent mass standards are provided:
table: Subpart A—PSES
column: Coating operation
as above
12.0 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (PSNS)
table: Subpart A—PSNS
column: Metal preparation
40 CFR 466.15 (PSNS)
Nickel 12.0 1.51 6.3 0.79
1.51 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (PSNS)
table: Subpart A—PSNS
column: Coating operation
as above
6.3 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (PSNS)
table: Subpart A—PSNS
column: Metal prepartion
as above
0.79 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (PSNS)
table: Subpart A—PSNS
column: Coating operation
as above
1.78 Mg/m² (pounds per/million ft²) of area coateddaily maximumdischarge to surface water
the discharge is of the Subpart B—Cast Iron Basis Material Subcategory
existing sources (BAT)
(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:
table: Subpart B—BAT Effluent Limitations
40 CFR 466.22 (BAT)
Nickel 1.78 (0.37) 1.26 (0.26)
1.26 Mg/m² (pounds per/million ft²) of area coatedmonthly averageas aboveas above
0.69 Mg/m² (pounds per million ft²) of area coateddaily maximumdischarge to surface water
the discharge is of the Subpart B—Cast Iron Basis Material Subcategory
new sources (NSPS)
(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:
table: Subpart B—NSPS
40 CFR 466.23 (NSPS)
Nickel 0.69 (0.14) 0.47 (0.10)
0.47 Mg/m² (pounds per million ft²) of area coatedmonthly averageas aboveas above
1.41 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Cast Iron Basis Material Subcategory
existing sources (PSES)
(2) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:
table: Subpart B—PSES
40 CFR 466.24 (PSES)
Nickel 1.41 1.00
1.00 mg/Lmonthly averageas aboveas above
1.78 mg/m (English Units—pounds per million ft²) of area coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Cast Iron Basis Material Subcategory
existing sources (PSES)
(2) The discharge of process watewater pollutants from all porcelain enameling costing operations shall not exceed the values set forth below:
table: Subpart B—PSES
40 CFR 466.24 (PSES)
Nickel 1.78 (0.37) 1.26 (0.26)
1.26 mg/m (English Units—pounds per million ft²) of area coatedmonthly averageas aboveas above
0.69 Mg/m² (pounds per million ft²) of area coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart B—Cast Iron Basis Material Subcategory
new sources (PSNS)
(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:
table: Subpart B—PSNS
40 CFR 466.25 (PSNS)
Nickel 0.69 (0.14) 0.47 (0.10)
0.47 Mg/m² (pounds per million ft²) of area coatedmonthly averageas aboveas above
54.85 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BPT)
table: Subpart C—BPT Effluent Limitations
column: Metal preparation
40 CFR 466.31 (BPT)
Nickel 54.85 21.21 38.90 15.04
21.21 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BPT)
table: Subpart C—BPT Effluent Limitations
column: Coating operation
as above
38.90 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BPT)
table: Subpart C—BPT Effluent Limitations
column: Metal preparation
as above
15.04 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BPT)
table: Subpart C—BPT Effluent Limitations
column: Coating operation
as above
54.85 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BAT)
table: Subpart C—BAT Effluent Limitations
column: Metal preparation
40 CFR 466.32 (BAT)
Nickel 54.85 1.78 38.90 1.26
1.78 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BAT)
table: Subpart C—BAT Effluent Limitations
column: Coating operation
as above
38.90 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BAT)
table: Subpart C—BAT Effluent Limitations
column: Metal preparation
as above
1.26 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BAT)
table: Subpart C—BAT Effluent Limitations
column: Coating operation
as above
5.35 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart C—NSPS
column: Metal preparation
40 CFR 466.33 (NSPS)
Nickel 5.35 0.69 3.60 0.47
0.69 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart C—NSPS
column: Coating operation
as above
3.60 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart C—NSPS
column: Metal preparation
as above
0.47 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart C—NSPS
column: Coating operation
as above
1.41 mg/Ldaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (PSES)
table: Subpart C—PSES
40 CFR 466.34 (PSES)
Nickel 1.41 1.00
1.00 mg/Lmonthly averageas aboveas above
54.85 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass pretreatment standards the following equivalent mass standards are provided:
table: Subpart C—PSES
column: Metal preparation
40 CFR 466.34 (PSES)
Nickel 54.85 1.78 38.9 1.26
1.78 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass pretreatment standards the following equivalent mass standards are provided:
table: Subpart C—PSES
column: Coating operation
as above
38.9 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass pretreatment standards the following equivalent mass standards are provided:
table: Subpart C—PSES
column: Metal preparation
as above
1.26 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (PSES)
(b) In cases where POTW find it necessary to impose mass pretreatment standards the following equivalent mass standards are provided:
table: Subpart C—PSES
column: Coating operation
as above
5.35 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (PSNS)
table: Subpart C—PSNS
column: Metal preparation
40 CFR 466.35 (PSNS)
Nickel 5.35 0.69 3.60 0.47
0.69 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (PSNS)
table: Subpart C—PSNS
column: Coating operation
as above
3.60 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (PSNS)
table: Subpart C—PSNS
column: Metal preparation
as above
0.47 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (PSNS)
table: Subpart C—PSNS
column: Coating operation
as above
9.25 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart D—NSPS
column: Metal preparation
40 CFR 466.43 (NSPS)
Nickel 9.25 0.69 6.23 0.47
0.69 mg/m² of area processed or coateddaily maximumdischarge to surface water
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart D—NSPS
column: Coating operation
as above
6.23 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart D—NSPS
column: Metal preparation
as above
0.47 mg/m² of area processed or coatedmonthly averagedischarge to surface water
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards:
table: Subpart D—NSPS
column: Coating operation
as above
9.25 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (PSNS)
Any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
table: Subpart D—PSNS
column: Metal preparation
40 CFR 466.45 (PSNS)
Nickel 9.25 0.69 6.23 0.47
0.69 mg/m² of area processed or coateddaily maximumdischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (PSNS)
Any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
table: Subpart D—PSNS
column: Coating operation
as above
6.23 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (PSNS)
Any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
table: Subpart D—PSNS
column: Metal preparation
as above
0.47 mg/m² of area processed or coatedmonthly averagedischarge to a sewer (pretreatment)
the discharge is of the Subpart D—Copper Basis Material Subcategory
new sources (PSNS)
Any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
table: Subpart D—PSNS
column: Coating operation
as above

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.