Passage Data · Cited limits by place · Use it from your AI
20 cited rows from 3 instruments, Indiana's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Indiana (US-IN) and United States. Everything held for Indiana
Indiana: surface water 5 · United States: drinking water 1, effluent 14
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Total dissolved solids | seven hundred fifty (750) milligrams per liter mg/L | — | waters of the state outside the Great Lakes system (327 IAC 2-1: 'Water Quality Standards Applicable to All State Waters Except Waters of the State Within the Great Lakes System') at the point where water is withdrawn for treatment for public water supply (327 IAC 2-1-6(e)) | 327 IAC 2-1-6(e)(4) · p. 21(4) The concentration of dissolved solids must not exceed seven hundred fifty (750) milligrams per liter unless due to naturally occurring sources. |
| Total dissolved solids | seven hundred fifty (750) milligrams per liter mg/L | — | waters of the state within the Great Lakes system (327 IAC 2-1.5-1) at the point where water is withdrawn for treatment for public water supply (327 IAC 2-1.5-8(f)) | 327 IAC 2-1.5-8(f)(4) · p. 84(4) The concentration of dissolved solids must not exceed seven hundred fifty (750) milligrams per liter unless due to naturally occurring sources. |
| Total dissolved solids | seven hundred fifty (750) milligrams per liter mg/L | instantaneous | waters of the state outside the Great Lakes system (327 IAC 2-1: 'Water Quality Standards Applicable to All State Waters Except Waters of the State Within the Great Lakes System') at the point where surface water is withdrawn for industrial cooling and processing | 327 IAC 2-1-6(f) · p. 21(f) In addition to subsection (a), dissolved solids must not exceed seven hundred fifty (750) milligrams per liter at any time other than from naturally occurring sources to ensure protection of water quality at the point at which surface water is withdrawn for use, either with or without treatment, for industrial cooling and processing. |
| Total dissolved solids | seven hundred fifty (750) milligrams per liter mg/L | instantaneous | waters of the state within the Great Lakes system (327 IAC 2-1.5-1) at the point where surface water is withdrawn for industrial cooling and processing | 327 IAC 2-1.5-8(g) · p. 84(g) In addition to subsection (b), dissolved solids must not exceed seven hundred fifty (750) milligrams per liter at any time, other than from naturally occurring sources, to ensure protection of water quality at the point at which surface water is withdrawn for use, either with or without treatment, for industrial cooling and processing. |
| Total dissolved solids | 750 mg/L | 4-day average | waters of the state within the Great Lakes system (327 IAC 2-1.5-1) the open waters of Lake Michigan (327 IAC 2-1.5-8(j)) | 327 IAC 2-1.5-8(j)(1) Table 8-9 · p. 85Total dissolved solids 750 mg/l[1] |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Total dissolved solids (TDS) | 500 mg/l | 40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States. | 143.3 |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| TDS | 306 mg/L | daily maximum | discharge to surface water existing sources (BAT) (3) Voluntary incentives plan. (i) For dischargers who voluntarily choose to meet the effluent limitations for FGD wastewater in this paragraph (g)(3)(i), the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 7 to this paragraph (g)(3)(i). Dischargers who choose to meet the effluent… table: Table 7 to Paragraph ( g )(3)( i ) | 40 CFR 423.13 (BAT)TDS (mg/L) 306 149 |
| TDS | 149 mg/L | monthly average | as above | as above |
| TDS | 50 mg/L | daily maximum | discharge to surface water new sources (NSPS) (13) FGD wastewater. The quantity of pollutants discharged in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in the following table: | 40 CFR 423.15 (NSPS)TDS (mg/L) 50 24 |
| TDS | 24 mg/L | monthly average | as above | as above |
| TDS | 50 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) (6) FGD wastewater. The quantity of pollutants discharged in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in the following table: | 40 CFR 423.17 (PSNS)TDS (mg/L) 50 24 |
| TDS | 24 mg/L | monthly average | as above | as above |
| Total dissolved solids | 38 mg/L | daily maximum | discharge to surface water existing sources (BAT) (j)(1)(i) Gasification wastewater. Except for those discharges to which paragraph (j)(2) of this section applies, the quantity of pollutants in gasification wastewater shall not exceed the quantity determined by multiplying the flow of gasification wastewater times the concentration listed in the table following this paragraph (j)(1)(i). Dischargers must meet the effluent limitations in this pa… | 40 CFR 423.13 (BAT)Total dissolved solids (mg/L) 38 22 |
| Total dissolved solids | 22 mg/L | monthly average | as above | as above |
| Total dissolved solids | 38 mg/L | daily maximum | discharge to surface water new sources (NSPS) (15) Gasification wastewater. The quantity of pollutants discharged in gasification wastewater shall not exceed the quantity determined by multiplying the flow of gasification wastewater times the concentration listed in the following table: | 40 CFR 423.15 (NSPS)Total dissolved solids (mg/L) 38 22 |
| Total dissolved solids | 22 mg/L | monthly average | as above | as above |
| Total dissolved solids | 38 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) (i) Gasification wastewater. For any electric generating unit with a total nameplate generating capacity of more than 50 megawatts and that is not an oil-fired unit, the quantity of pollutants in gasification wastewater shall not exceed the quantity determined by multiplying the flow of gasification wastewater times the concentration listed in the table following this paragraph (i). Dischargers… | 40 CFR 423.16 (PSES)Total dissolved solids (mg/L) 38 22 |
| Total dissolved solids | 22 mg/L | monthly average | as above | as above |
| Total dissolved solids | 38 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) (9) Gasification wastewater. The quantity of pollutants discharged in gasification wastewater shall not exceed the quantity determined by multiplying the flow of gasification wastewater times the concentration listed in the following table: | 40 CFR 423.17 (PSNS)Total dissolved solids (mg/L) 38 22 |
| Total dissolved solids | 22 mg/L | monthly average | as above | as above |
69 instruments we hold for Indiana (US-IN) and United States, for 1 name matching “tds” (each in the JSON). 3 have a row, in the tables above; 66 have none.
The address: https://passage-data.com/mcp