Passage Data · Cited limits by place · Use it from your AI
108 cited rows from 2 instruments, Indiana's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Indiana (US-IN) and United States. Everything held for Indiana
| Value | Applies when | Cite |
|---|---|---|
| C = [-57.478 + 5.79 (hardness) + 54.163 (chloride)] × 0.65 mg/L | hardness 100 to 500 mg/l CaCO3 chloride 5 to under 25 mg/l in the receiving water; the formula as printed | 327 IAC 2-1-6(a)(8)(A) · p. 16C = [-57.478 + 5.79 (hardness) + 54.163 (chloride)] × 0.65 |
| C = [1276.7 + 5.508 (hardness) - 1.457 (chloride)] × 0.65 mg/L | hardness 100 to 500 mg/l CaCO3 chloride 25 to 500 mg/l in the receiving water; the formula as printed | 327 IAC 2-1-6(a)(8)(A) · p. 16C = [1276.7 + 5.508 (hardness) - 1.457 (chloride)] × 0.65 |
| five hundred (500) mg/L | hardness less than 100 mg/l CaCO3 chloride at most 500 mg/l in the receiving water | 327 IAC 2-1-6(a)(8)(A)(iii) · p. 16(iii) If the hardness concentration of surface waters is less than one hundred (100) mg/l and the chloride concentration of surface waters is less than or equal to five hundred (500) mg/l, the sulfate criterion is five hundred (500) mg/l. |
| five hundred (500) mg/L | chloride less than 5 mg/l in the receiving water | 327 IAC 2-1-6(a)(8)(A)(v) · p. 16(v) If the chloride concentration of surface waters is less than five (5) mg/l, the sulfate criterion is five hundred (500) mg/l. |
| 515 mg/L | hardness 100 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | 327 IAC 2-1-6(a)(8)(C) Table 6-5 · p. 175 500 515 703 891 1080 1268 1456 1644 1832 2020 2020 |
| 703 mg/L | hardness 150 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | as above |
| 891 mg/L | hardness 200 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | as above |
| 1080 mg/L | hardness 250 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | as above |
| 1268 mg/L | hardness 300 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | as above |
| 1456 mg/L | hardness 350 mg/l CaCO3 (the table's column) chloride 5 mg/l in the receiving water (the table's row) | as above |
All 107 rows from Indiana 327 IAC 2 Water Quality Standards
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Applies when | Cite |
|---|---|---|
| 250 mg/l | 40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States. | 143.3 |
This page shows 11 of 108 rows: every instrument, each with its first 10 rows or all of them. All 108 as JSON, 200 a page.
1 NPDES permit in Indiana went over a sulfate limit in their last 12 months of reports: the list as JSON.
69 instruments we hold for Indiana (US-IN) and United States, for 50 names matching “sulfate” (each in the JSON). 2 have a row, in the tables above; 67 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the sulfate limits in Indiana? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=sulfate&place=US-IN; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.