Passage Data · Cited limits by place · Use it from your AI
137 cited rows from 5 instruments, Indiana's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Indiana (US-IN) and United States. Everything held for Indiana
United States: drinking water 3, effluent 128, leachate 1, soil 4, product 1
The one instrument we hold for Indiana (US-IN) has no row for beryllium. The rows below are from the place above it, which we search too.
| Value | Kind | Applies when | Cite |
|---|---|---|---|
| .004 mg/l | guideline | 40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals. | 141.51, 141.62 |
| 0.004 mg/l | limit | 40 CFR 141.2: Maximum contaminant level means the maximum permissible level of a contaminant in water which is delivered to any user of a public water system. | as above |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Beryllium and compounds | 25 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 2,763.000 mg/kg (pounds per million pounds) of beryllium carbonate produced from bertrandite ore as beryllium | daily maximum | (a) Solvent Extraction Raffinate from Bertrandite Ore. | 40 CFR 421.152 (BPT)Beryllium 2,763.000 1,235.000 |
| 1,235.000 mg/kg (pounds per million pounds) of beryllium carbonate produced from bertrandite ore as beryllium | monthly average | as above | as above |
| 270.6 mg/kg (pounds per million pounds) of beryllium carbonate produced from beryl ore as beryllium | daily maximum | (b) Solvent Extraction Raffinate from Beryl Ore. | 40 CFR 421.152 (BPT)Beryllium 270.6 121.0 |
| 121.0 mg/kg (pounds per million pounds) of beryllium carbonate produced from beryl ore as beryllium | monthly average | as above | as above |
| 263.800 mg/kg (pounds per million pounds) of beryllium carbonate produced as beryllium | daily maximum | (c) Beryllium Carbonate Filtrate. | 40 CFR 421.152 (BPT)Beryllium 263.800 118.000 |
| 118.000 mg/kg (pounds per million pounds) of beryllium carbonate produced as beryllium | monthly average | as above | as above |
| 167.280 mg/kg (pounds per million pounds) of beryllium hydroxide produced as beryllium | daily maximum | (d) Beryllium Hydroxide Filtrate. | 40 CFR 421.152 (BPT)Beryllium 167.280 74.800 |
| 74.800 mg/kg (pounds per million pounds) of beryllium hydroxide produced as beryllium | monthly average | as above | as above |
| 324.000 mg/kg (pounds per million pounds) of beryllium oxide produced | daily maximum | (e) Beryllium Oxide Calcining Furnace Wet Air Pollution Control. | 40 CFR 421.152 (BPT)Beryllium 324.000 145.000 |
| 145.000 mg/kg (pounds per million pounds) of beryllium oxide produced | monthly average | as above | as above |
All 128 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.22 mg/L TCLP | instantaneous | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standardBeryllium 7440-41-7 0.82 1.22 mg/l TCLP |
| Parameter | Value | Kind | Applies when | Cite |
|---|---|---|---|---|
| Beryllium and compounds | 160 mg/kg | guideline | Resident Soil (mg/kg) | source |
| Beryllium and compounds | 2300 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
| Beryllium and compounds | 19 mg/kg | guideline | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Beryllium and compounds | 3.2 mg/kg | reference value (not a limit) | Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.82 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standardBeryllium 7440-41-7 0.82 1.22 mg/l TCLP |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
This page shows 19 of 137 rows: every instrument, each with its first 10 rows or all of them. All 137 as JSON, 200 a page.
69 instruments we hold for Indiana (US-IN) and United States, for 3 names matching “beryllium” (each in the JSON). 5 have a row, in the tables above; 64 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the beryllium limits in Indiana? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=beryllium&place=US-IN; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.