Passage Data · Cited limits by place · Use it from your AI
14 cited rows from 1 instrument, Illinois's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Illinois (US-IL) and United States. Everything held for Illinois
The one instrument we hold for Illinois (US-IL) has no row for cn, a. The rows below are from the place above it, which we search too.
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart D—Anodizing Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.44 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart E—Coatings Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart E—Coatings Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.54 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart F—Chemical Etching and Milling Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart F—Chemical Etching and Milling Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.64 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN, A | 5.0 mg/L | daily maximum | the discharge is of the Subpart H—Printed Circuit Board Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart H—Printed Circuit Board Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.84 (PSES)CN, A 5.0 2.7 |
| CN, A | 2.7 mg/L | — | as above | as above |
| CN,A | 5.0 mg/L | daily maximum | the discharge is of the Subpart G—Electroless Plating Subcategory (b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart G—Electroless Plating Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.74 (PSES)CN,A 5.0 2.7 |
| CN,A | 2.7 mg/L | — | as above | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
69 instruments we hold for Illinois (US-IL) and United States, for 1 name matching “cn a” (each in the JSON). 1 has a row, in the tables above; 68 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the cn, a limits in Illinois? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=cn%20a&place=US-IL; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI