Passage Data · Cited limits by place · Use it from your AI

Lead limits and guidelines in Idaho (US-ID)

3,207 cited rows from 27 instruments, Idaho's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Idaho (US-ID) and United States. Everything held for Idaho

Idaho: surface water 4 · United States: drinking water 7, surface water 6, effluent 3,169, leachate 2, soil 15, ambient air 2, air emission 1, product 1

Idaho (US-ID): 4 rows

Surface water: 4 rows

Idaho IDAPA 58.01.02 Water Quality Standards Section 210 · IDAPA 58.01.02 effective June 10, 2026, as US EPA posts it in effect for CWA purposes · 4 guidelines
Every row: receiving water: freshwater; surface waters designated for aquatic life use (cold water, salmonid spawning, seasonal cold water, warm water or modified; designations by water body unit in IDAPA 58.01.02.110-160)
ValueStatisticApplies whenCite
65 µg/L1-hour averagetotal hardness 100 mg/L as calcium carbonate (note f: the example values correspond to it)
water effect ratio of one (1.0): note f's example values assume it
IDAPA 58.01.02.210 Table 1 · p. 148
2.5 µg/L4-day averageas aboveas above
CMC=WER exp{mA[ln(hardness)]+bA} X Acute Conversion Factor; mA 1.273, bA -1.460, CF 0.791 µg/L1-hour averagehardness-dependent: Subsection 210.02's equation of total hardness (mg/L CaCO3), times the water effect ratio and the conversion factor (cadmium and lead CF hardness-dependent, note a); printed, not evaluatedIDAPA 58.01.02.210.02 · p. 158
CCC=WER exp{mc[ln(hardness)]+bc} X Chronic Conversion Factor; mc 1.273, bc -4.705, CF 0.791 µg/L4-day averageas aboveas above

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

United States (US): 3,203 rows

Drinking water: 7 rows

40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01 · 2 rows
ValueKindApplies whenCite
zeroguideline40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals.141.51
0.010 mg/Lthreshold40 CFR 141.2: Action level, for the purpose of subpart I of this part only, means the concentrations of lead or copper in water as specified in § 141.80(c) which determines requirements under subpart I of this part.
90th percentile concentration of lead as specified in paragraph (c)(3) of this section
(3) Community water systems and non-transient non-community water systems must comply with the requirements of this subpart no later than November 1, 2027
141.80(c)(1)
(1) The lead action level is exceeded if the 90th percentile concentration of lead as specified in paragraph (c)(3) of this section is greater than 0.010 mg/L.
US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water · November 2024 · 5 guidelines
Every row: Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024
ParameterValueCite
~Lead and Compounds10 µg/Lsource
~Lead acetate0.37 µg/Las above
~Lead subacetate2.1 µg/Las above
~Lead Phosphate9.1 µg/Las above
~Tetraethyl Lead0.0013 µg/Las above

Surface water: 6 rows

EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC) · EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year · 6 guidelines
Every row: EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use
ValueApplies whenCite
65 µg/Lreceiving water: freshwater
Freshwater CMC (acute): criterion maximum concentration, acute
corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness)
National Recommended Aquatic Life Criteria table
Lead (P) 7439921 65 2.5 210 8.1 1984
exp{1.273 [ln(hardness)] + -1.460} × CF, CF = 1.46203-[( ln hardness)(0.145712)] µg/Lreceiving water: freshwater
Freshwater CMC (acute), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here
Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-Dependent
Lead 1.273 -1.460 1.273 -4.705 1.46203-[( ln hardness)(0.145712)] 1.46203-[( ln hardness)(0.145712)]
2.5 µg/Lreceiving water: freshwater
Freshwater CCC (chronic): criterion continuous concentration, chronic
corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness)
National Recommended Aquatic Life Criteria table
Lead (P) 7439921 65 2.5 210 8.1 1984
exp{1.273 [ln(hardness)] + -4.705} × CF, CF = 1.46203-[( ln hardness)(0.145712)] µg/Lreceiving water: freshwater
Freshwater CCC (chronic), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here
Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-Dependent
Lead 1.273 -1.460 1.273 -4.705 1.46203-[( ln hardness)(0.145712)] 1.46203-[( ln hardness)(0.145712)]
210 µg/Lreceiving water: marine
Saltwater CMC (acute): criterion maximum concentration, acute
National Recommended Aquatic Life Criteria table
Lead (P) 7439921 65 2.5 210 8.1 1984
8.1 µg/Lreceiving water: marine
Saltwater CCC (chronic): criterion continuous concentration, chronic
as above

Effluent: 3,169 rows

40 CFR Part 413 — Electroplating point source category · eCFR as of 2026-10-05 · 56 limits, 5 shown
Every row: discharge to a sewer (pretreatment); the discharge is of the Subpart A—Electroplating of Common Metals Subcategory; existing sources (PSES)
ParameterValueStatisticApplies whenCite
Pb.6 mg/Ldaily maximum(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)
40 CFR 413.14 (PSES)
Pb .6 .4
Pb.4 mg/L—as aboveas above
Pb.6 mg/Ldaily maximum(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)
as above
Pb.4 mg/L—as aboveas above
Pb23 mg/sq m-Operationdaily maximum(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:
table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)
40 CFR 413.14 (PSES)
Pb 23 16

All 56 rows from 40 CFR Part 413 — Electroplating point source category

40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers · eCFR as of 2026-08-01 · 10 limits, 5 shown
Every row: (a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i; discharge to surface water
ParameterValueStatisticApplies whenCite
Total Lead690 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Lead 690 320
Total Lead690 µg/Ldaily maximumthe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Lead 690 320
Total Lead320 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (BAT)
Total Lead 690 320
Total Lead320 µg/Lmonthly averagethe discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment
new sources (NSPS)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…
40 CFR 414.91 (NSPS)
Total Lead 690 320
Total Lead690 µg/Ldaily maximumthe discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment
existing sources (BAT)
(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…
40 CFR 414.101 (BAT)
Total Lead 690 320

All 10 rows from 40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers

40 CFR Part 415 — Inorganic chemicals manufacturing point source category · eCFR as of 2026-08-01 · 24 limits, 5 shown
Every row: the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)
ParameterValueStatisticApplies whenCite
Lead (T)0.026 Kg/kkg (or pounds per/1,000 lb) of productdaily maximumdischarge to surface water
existing sources (BPT)
table: Subpart F—Chlor-Alkali Diaphragm Cells
40 CFR 415.62 (BPT)
Lead (T) 0.026 0.010
Lead (T)0.010 Kg/kkg (or pounds per/1,000 lb) of productmonthly averageas aboveas above
Lead (T)0.0059 Kg/kkg (or pounds per 1,000 lb) of productdaily maximumdischarge to surface water
existing sources (BAT)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.63 (BAT)
Lead (T) 0.0059 0.0024
Lead (T)0.0024 Kg/kkg (or pounds per 1,000 lb) of productmonthly averageas aboveas above
Lead (T)2.9 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Subpart F—Chlor-Alkali-Diaphragm Cells
40 CFR 415.64 (PSES)
Lead (T) 2.9 1.1

All 24 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category

40 CFR Part 420 — Iron and steel manufacturing point source category · eCFR as of 2026-10-05 · 246 limits, 5 shown
Every row: the discharge is of the Subpart B—Sintering Subcategory
ValueStatisticApplies whenCite
0.000451 Pounds per thousand lb of productdaily maximumdischarge to surface water
existing sources (BAT)
(a) Sintering operations with wet air pollution control system. The following table presents BAT limitations for sintering operations with wet air pollution control systems:
table: Subpart B—Effluent Limitations (BAT)
40 CFR 420.23 (BAT)
Lead 0.000451 0.000150
0.000150 Pounds per thousand lb of productmonthly averageas aboveas above
0.000451 Pounds per thousand lb of productdaily maximumdischarge to surface water
new sources (NSPS)
(1) Sintering operations with wet air pollution control system. The following table presents NSPS for sintering operations with wet air pollution control systems:
table: Subpart B—New Source Performance Standards (NSPS)
40 CFR 420.24 (NSPS)
Lead 0.000451 0.000150
0.000150 Pounds per thousand lb of productmonthly averageas aboveas above
0.000451 Pounds per thousand lb of productdaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
(a) Sintering operations with wet air pollution control system. The following table presents PSES for sintering operations with wet air pollution control systems:
table: Subpart B—Pretreatment Standards for Existing Sources (PSES)
40 CFR 420.25 (PSES)
Lead 0.000451 0.000150

All 246 rows from 40 CFR Part 420 — Iron and steel manufacturing point source category

40 CFR Part 421 — Nonferrous metals manufacturing point source category · eCFR as of 2026-10-05 · 1,292 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory; existing sources (BAT); table: BAT Effluent Limitations
ValueStatisticApplies whenCite
.000 mg/kg (pound's per million pounds) of aluminum scrap drieddaily maximum(a) Subpart C—Scrap Drying Wet Air Pollution Control.40 CFR 421.33 (BAT)
Lead .000 .000
.000 mg/kg (pound's per million pounds) of aluminum scrap driedmonthly averageas aboveas above
.000 mg/kg (pound's per million pounds) of aluminum scrap screened and milleddaily maximum(b) Subpart C—Scrap Screening and Milling.as above
.000 mg/kg (pound's per million pounds) of aluminum scrap screened and milledmonthly averageas aboveas above
3.043 mg/kg (pound's per million pounds) of dross washeddaily maximum(c) Subpart C—Dross Washing.40 CFR 421.33 (BAT)
Lead 3.043 1.413

All 1,292 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category

40 CFR Part 426 — Glass manufacturing point source category · eCFR as of 2026-10-05 · 10 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart K—Television Picture Tube Envelope Manufacturing Subcategory
ValueStatisticApplies whenCite
39.0 g/kkg of furnace pulldaily maximumexisting sources (BPT)40 CFR 426.112 (BPT)
Lead 39.0 4.5
4.5 g/kkg of furnace pullmonthly averageas aboveas above
0.9 g/kkg of furnace pulldaily maximumexisting sources (BAT)
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams.
40 CFR 426.113 (BAT)
Lead 0.9 0.45
0.45 g/kkg of furnace pullmonthly averageas aboveas above
30.9 g/kkg of furnace pulldaily maximumnew sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the…
40 CFR 426.115 (NSPS)
Lead 30.9 0.45

All 10 rows from 40 CFR Part 426 — Glass manufacturing point source category

40 CFR Part 428 — Rubber manufacturing point source category · eCFR as of 2026-10-05 · 28 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart E—Small-Sized General Molded, Extruded, and Fabricated Rubber Plants Subcategory
ValueStatisticApplies whenCite
0.0017 kg/kkg of raw materialdaily maximumexisting sources (BPT)
(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available, in addition to the limitations set forth by § 428…
40 CFR 428.52 (BPT)
Lead 0.0017 0.0007
0.0007 kg/kkg of raw materialmonthly averageas aboveas above
0.0017 kg/kkg of raw materialdaily maximumexisting sources (BAT)
(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable, in addition to the limitations set forth by § 428.53(a):
40 CFR 428.53 (BAT)
Lead 0.0017 0.0007
0.0007 kg/kkg of raw materialmonthly averageas aboveas above
0.0017 kg/kkg of raw materialdaily maximumnew sources (NSPS)
(b) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a new source subject to the provisions of this subpart, in addition to the limitations set forth by § 428.55(a):
40 CFR 428.55 (NSPS)
Lead 0.0017 0.0007

All 28 rows from 40 CFR Part 428 — Rubber manufacturing point source category

40 CFR Part 433 — Metal finishing point source category · eCFR as of 2026-10-05 · 10 limits, 5 shown
Every row: the discharge is of the Subpart A—Metal Finishing Subcategory
ParameterValueStatisticApplies whenCite
Lead (T)0.69 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: BPT Effluent Limitations
40 CFR 433.13 (BPT)
Lead (T) 0.69 0.43
Lead (T)0.43 mg/Lmonthly averageas aboveas above
Lead (T)0.69 mg/Ldaily maximumdischarge to surface water
existing sources (BAT)
table: BAT Effluent Limitations
40 CFR 433.14 (BAT)
Lead (T) 0.69 0.43
Lead (T)0.43 mg/Lmonthly averageas aboveas above
Lead (T)0.69 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers
40 CFR 433.15 (PSES)
Lead (T) 0.69 0.43

All 10 rows from 40 CFR Part 433 — Metal finishing point source category

40 CFR Part 437 — The centralized waste treatment point source category · eCFR as of 2026-10-05 · 40 limits, 5 shown
Every row: discharge to surface water
ValueStatisticApplies whenCite
1.32 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.11 (BPT)
Lead 1.32 0.283
0.283 mg/Lmonthly averageas aboveas above
1.32 mg/Ldaily maximumthe discharge is of the Subpart A—Metals Treatment and Recovery
new sources (NSPS)
table: Performance Standards
40 CFR 437.14 (NSPS)
Lead 1.32 0.283
0.283 mg/Lmonthly averageas aboveas above
0.350 mg/Ldaily maximumthe discharge is of the Subpart B—Oils Treatment and Recovery
existing sources (BPT)
table: BPT Limitations
40 CFR 437.21 (BPT)
Lead 0.350 0.160

All 40 rows from 40 CFR Part 437 — The centralized waste treatment point source category

40 CFR Part 440 — Ore mining and dressing point source category · eCFR as of 2026-10-05 · 22 limits, 5 shown
Every row: discharge to surface water; existing sources (BPT)
ParameterValueStatisticApplies whenCite
Pb.6 mg/Ldaily maximumthe discharge is of the Subpart F—Tungsten Ore Subcategory
(a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed:
40 CFR 440.62 (BPT)
Pb .6 .3
Pb.3 mg/Lmonthly averageas aboveas above
Pb.6 mg/Ldaily maximumthe discharge is of the Subpart G—Nickel Ore Subcategory
(a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of nickel bearing ores per year shall not exceed:
40 CFR 440.72 (BPT)
Pb .6 .3
Pb.3 mg/Lmonthly averageas aboveas above
Pb.6 mg/Ldaily maximumthe discharge is of the Subpart H—Vanadium Ore Subcategory (Mined Alone and Not as a Byproduct)
(a) The concentration of pollutants discharged in mine drainage from mines producing 5,000 metric tons (5,512 short tons) or more of vanadium bearing ores per year shall not exceed:
40 CFR 440.82 (BPT)
Pb .6 .3

All 22 rows from 40 CFR Part 440 — Ore mining and dressing point source category

40 CFR Part 442 — Transportation equipment cleaning point source category · eCFR as of 2026-10-05 · 2 limits
Every row: the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos
ValueStatisticApplies whenCite
0.14 mg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: Table—Effluent Limitations
40 CFR 442.31 (BPT)
Lead 0.14
0.14 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Table—Pretreatment Standards
40 CFR 442.35 (PSES)
Lead 0.14
40 CFR Part 444 — Waste combustors point source category · eCFR as of 2026-10-05 · 4 limits
Every row: the discharge is of the Subpart A—Commercial Hazardous Waste Combustor Subcategory
ValueStatisticApplies whenCite
57 µg/Ldaily maximumdischarge to surface water
existing sources (BPT)
table: Effluent Limitations 1
40 CFR 444.13 (BPT)
Lead 57 32
32 µg/Lmonthly averageas aboveas above
57 µg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
table: Pretreatment Standards 1
40 CFR 444.16 (PSES)
Lead 57 32
32 µg/Lmonthly averageas aboveas above
40 CFR Part 461 — Battery manufacturing point source category · eCFR as of 2026-10-05 · 130 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart C—Lead Subcategory; existing sources (BPT); table: BPT Effluent Limitations
ValueStatisticApplies whenCite
0.19 mg/kg of lead useddaily maximum(1) Subpart C—Closed Formation—Double Fill, or Fill and Dump.40 CFR 461.31 (BPT)
Lead 0.19 0.090
0.090 mg/kg of lead usedmonthly averageas aboveas above
4.64 mg/kg of lead useddaily maximum(2) Subpart C—Open Formation—Dehydrated.40 CFR 461.31 (BPT)
Lead 4.64 2.21
2.21 mg/kg of lead usedmonthly averageas aboveas above
0.02 mg/kg of lead useddaily maximum(3) Subpart C—Open Formation—Wet.40 CFR 461.31 (BPT)
Lead 0.02 0.01

All 130 rows from 40 CFR Part 461 — Battery manufacturing point source category

40 CFR Part 464 — Metal molding and casting point source category · eCFR as of 2026-10-05 · 587 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Aluminum Casting Subcategory; existing sources (BPT); (a) Casting Cleaning Operations.
ParameterValueStatisticApplies whenCite
Lead (T)0.0791 kg/1,000 kkg (pounds per million pounds) of metal poureddaily maximumtable: BPT Effluent Limitations40 CFR 464.12 (BPT)
Lead (T) 0.0791 0.039
Lead (T)0.039 kg/1,000 kkg (pounds per million pounds) of metal pouredmonthly averageas aboveas above
Lead (T)0.79 mg/Ldaily maximum40 CFR 464.12 (BPT)
Lead (T) 0.79 0.39 0.022
Lead (T)0.39 mg/Lmonthly averageas above
Lead (T)0.022 kg/1,000 kkg (pounds per million pounds) of metal pouredannual averageas above

All 587 rows from 40 CFR Part 464 — Metal molding and casting point source category

40 CFR Part 466 — Porcelain enameling point source category · eCFR as of 2026-10-05 · 64 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Steel Basis Material Subcategory
ValueStatisticApplies whenCite
6.01 mg/m² of area processed or coateddaily maximumexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
40 CFR 466.11 (BPT)
Lead 6.01 1.21 5.21 1.06
1.21 mg/m² of area processed or coateddaily maximumexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
5.21 mg/m² of area processed or coatedmonthly averageexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Metal preparation
as above
1.06 mg/m² of area processed or coatedmonthly averageexisting sources (BPT)
table: Subpart A—BPT Effluent Limitations
column: Coating operation
as above
6.01 mg/m² of area processed or coateddaily maximumexisting sources (BAT)
table: Subpart A—BAT Effluent Limitations
column: Metal preparation
40 CFR 466.12 (BAT)
Lead 6.01 0.19 5.21 0.16

All 64 rows from 40 CFR Part 466 — Porcelain enameling point source category

40 CFR Part 468 — Copper forming point source category · eCFR as of 2026-10-05 · 170 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Copper Forming Subcategory; existing sources (BPT)
ValueStatisticApplies whenCite
0.015 mg/off-kg of copper or copper alloy hot rolleddaily maximum(a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Lead 0.015 0.013
0.013 mg/off-kg of copper or copper alloy hot rolledmonthly averageas aboveas above
0.056 mg/off-kg of copper or copper alloy cold rolleddaily maximum(b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Lead 0.056 0.049
0.049 mg/off-kg of copper or copper alloy cold rolledmonthly averageas aboveas above
0.012 mg/off-kg of copper or copper alloy drawndaily maximum(c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations.40 CFR 468.11 (BPT)
Lead 0.012 0.011

All 170 rows from 40 CFR Part 468 — Copper forming point source category

40 CFR Part 469 — Electrical and electronic components point source category · eCFR as of 2026-10-05 · 6 limits
Every row: the discharge is of the Subpart C—Cathode Ray Tube Subcategory
ValueStatisticApplies whenCite
1.12 mg/Ldaily maximumdischarge to a sewer (pretreatment)
existing sources (PSES)
40 CFR 469.34 (PSES)
Lead 1.12 0.41
0.41 mg/Lmonthly averageas aboveas above
0.72 mg/Ldaily maximumdischarge to surface water
new sources (NSPS)
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
40 CFR 469.35 (NSPS)
Lead 0.72 0.27
0.27 mg/Lmonthly averageas aboveas above
0.72 mg/Ldaily maximumdischarge to a sewer (pretreatment)
new sources (PSNS)
40 CFR 469.36 (PSNS)
Lead 0.72 0.27
0.27 mg/Lmonthly averageas aboveas above
40 CFR Part 471 — Nonferrous metals forming and metal powders point source category · eCFR as of 2026-10-05 · 468 limits, 5 shown
Every row: discharge to surface water; the discharge is of the Subpart A—Lead-Tin-Bismuth Forming Subcategory; existing sources (BPT); table: Subpart A—BPT
ValueStatisticApplies whenCite
0.010 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth rolled with emulsionsdaily maximum(a) Rolling spent emulsions.40 CFR 471.11 (BPT)
Lead 0.010 0.005
0.005 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth rolled with emulsionsmonthly averageas aboveas above
0.019 mg/off-kg (pounds per million off-pound) of lead-tin-bismuth rolled with soap solutionsdaily maximum(b) Rolling spent soap solutions.40 CFR 471.11 (BPT)
Lead 0.019 0.009
0.009 mg/off-kg (pounds per million off-pound) of lead-tin-bismuth rolled with soap solutionsmonthly averageas aboveas above
0.011 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth drawn with emulsionsdaily maximum(d) Drawing spent emulsions.40 CFR 471.11 (BPT)
Lead 0.011 0.005

All 468 rows from 40 CFR Part 471 — Nonferrous metals forming and metal powders point source category

Leachate: 2 rows

40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity… · eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day) · 1 threshold
ValueApplies whenCite
5.0 mg/L(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section.40 CFR 261.24, Table 1
D008 Lead 7439-92-1 5.0
40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 1 limit
ValueStatisticApplies whenCite
0.75 mg/L TCLPinstantaneous(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard
Lead 7439-92-1 0.69 0.75 mg/l TCLP

Soil: 15 rows

US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil · November 2024 · 15 rows, 5 shown
ParameterValueKindApplies whenCite
~Lead and Compounds200 mg/kgguidelineResident Soil (mg/kg)source
~Lead and Compounds800 mg/kgguidelineIndustrial Soil (mg/kg)as above
~Lead and Compounds (with other sources of lead present, see Guidance)100 mg/kgguidelineResident Soil (mg/kg)as above
~Lead and Compounds9 mg/kgreference value (not a limit)Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1as above
~Lead acetate2.6 mg/kgguidelineResident Soil (mg/kg)as above

All 15 rows from US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil

Ambient air: 2 rows

40 CFR Part 50, National Primary and Secondary Ambient Air Quality Standards, §§ 50.4–50.21 (eCFR as of 2026-08-01) · 90 FR 4651, Jan. 16, 2025 · 2 limits
Every row: maximum arithmetic 3-month mean concentration for a 3-year period
ValueCite
0.15 µg/m³§ 50.16 National primary and secondary ambient air quality standards for lead.
(a) The national primary and secondary ambient air quality standards for lead (Pb) and its compounds are 0.15 micrograms per cubic meter, arithmetic mean concentration over a 3-month period, measured in the ambient air as Pb either by:
0.15 µg/m³as above

Air emission: 1 row

40 CFR 52.21 — Prevention of significant deterioration of air quality · eCFR 2026-08-01 · 1 threshold
ValueCite
0.6 tpy52.21(b)(23)(i)
Lead: 0.6 tpy

Product: 1 row

40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the… · eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13,… · 1 limit
ValueStatisticApplies whenCite
0.69 mg/Lcomposite sample(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS.40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard
Lead 7439-92-1 0.69 0.75 mg/l TCLP

This page shows 115 of 3,207 rows: every instrument, each with its first 5 rows or all of them. All 3,207 as JSON, 200 a page.

2 NPDES permits in Idaho went over a lead limit in their last 12 months of reports: the list as JSON.

What was searched

69 instruments we hold for Idaho (US-ID) and United States, for 26 names matching “lead” (each in the JSON). 27 have a row, in the tables above; 42 have none.

42 instruments with no row for lead
  1. 40 CFR 63.2 — Definitions (major source of hazardous air pollutants) · eCFR 2026-08-01
  2. 40 CFR Part 133 — Secondary Treatment Regulation · eCFR as of 2026-10-05
  3. 40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01) · eCFR as of 2026-08-01
  4. 40 CFR Part 405 — Dairy products processing point source category · eCFR as of 2026-10-05
  5. 40 CFR Part 406 — Grain mills point source category · eCFR as of 2026-10-05
  6. 40 CFR Part 407 — Canned and preserved fruits and vegetables processing point source category · eCFR as of 2026-10-05
  7. 40 CFR Part 408 — Canned and preserved seafood processing point source category · eCFR as of 2026-10-05
  8. 40 CFR Part 409 — Sugar processing point source category · eCFR as of 2026-10-05
  9. 40 CFR Part 410 — Textile mills point source category · eCFR as of 2026-10-05
  10. 40 CFR Part 411 — Cement manufacturing point source category · eCFR as of 2026-10-05
  11. 40 CFR Part 412 — Concentrated animal feeding operations (CAFO) point source category · eCFR as of 2026-10-05
  12. 40 CFR Part 417 — Soap and detergent manufacturing point source category · eCFR as of 2026-10-05
  13. 40 CFR Part 418 — Fertilizer manufacturing point source category · eCFR as of 2026-08-01
  14. 40 CFR Part 419 — Petroleum refining point source category · eCFR as of 2026-10-05
  15. 40 CFR Part 422 — Phosphate manufacturing point source category · eCFR as of 2026-08-01
  16. 40 CFR Part 423 — Steam electric power generating point source category · eCFR as of 2026-10-05
  17. 40 CFR Part 424 — Ferroalloy manufacturing point source category · eCFR as of 2026-10-05
  18. 40 CFR Part 425 — Leather tanning and finishing point source category · eCFR as of 2026-10-05
  19. 40 CFR Part 427 — Asbestos manufacturing point source category · eCFR as of 2026-10-05
  20. 40 CFR Part 429 — Timber products processing point source category · eCFR as of 2026-10-05
  21. 40 CFR Part 430 — The pulp, paper, and paperboard point source category · eCFR as of 2026-10-05
  22. 40 CFR Part 432 — Meat and poultry products point source category · eCFR as of 2026-10-05
  23. 40 CFR Part 434 — Coal mining point source category BPT, BAT, BCT limitations and new source performance standards · eCFR as of 2026-10-05
  24. 40 CFR Part 435 — Oil and gas extraction point source category · eCFR as of 2026-10-05
  25. 40 CFR Part 436 — Mineral mining and processing point source category · eCFR as of 2026-10-05
  26. 40 CFR Part 438 — Metal products and machinery point source category · eCFR as of 2026-10-05
  27. 40 CFR Part 439 — Pharmaceutical manufacturing point source category · eCFR as of 2026-10-05
  28. 40 CFR Part 443 — Effluent limitations guidelines for existing sources and standards of performance and pretreatment… · eCFR as of 2026-10-05
  29. 40 CFR Part 445 — Landfills point source category · eCFR as of 2026-10-05
  30. 40 CFR Part 446 — Paint formulating point source category · eCFR as of 2026-10-05
  31. 40 CFR Part 447 — Ink formulating point source category · eCFR as of 2026-10-05
  32. 40 CFR Part 449 — Airport deicing point source category · eCFR as of 2026-10-05
  33. 40 CFR Part 454 — Gum and wood chemicals manufacturing point source category · eCFR as of 2026-10-05
  34. 40 CFR Part 455 — Pesticide chemicals · eCFR as of 2026-10-05
  35. 40 CFR Part 457 — Explosives manufacturing point source category · eCFR as of 2026-10-05
  36. 40 CFR Part 458 — Carbon black manufacturing point source category · eCFR as of 2026-08-01
  37. 40 CFR Part 459 — Photographic point source category · eCFR as of 2026-10-05
  38. 40 CFR Part 460 — Hospital point source category · eCFR as of 2026-10-05
  39. 40 CFR Part 463 — Plastics molding and forming point source category · eCFR as of 2026-10-05
  40. 40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05
  41. 40 CFR Part 467 — Aluminum forming point source category · eCFR as of 2026-10-05
  42. EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only) · EPA web table (fetched 2026-10-09); each criterion carries its publication year
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the lead limits in Idaho? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=lead&place=US-ID; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI