Passage Data · Cited limits by place · Use it from your AI
467 cited rows from 17 instruments, Idaho's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Idaho (US-ID) and United States. Everything held for Idaho
Idaho: surface water 4 · United States: drinking water 3, surface water 7, effluent 446, leachate 2, soil 4, product 1
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 340 µg/L | 1-hour average | surface waters designated for aquatic life use (cold water, salmonid spawning, seasonal cold water, warm water or modified; designations by water body unit in IDAPA 58.01.02.110-160) times the water effect ratio (WER, Subsection 210.03.c.iii; 1.0 unless a WER is derived): note c | IDAPA 58.01.02.210 Table 1 · p. 148 |
| 150 µg/L | 4-day average | as above | as above |
| 10 µg/L | — | surface waters designated for domestic water supply use (Table 2 'Water & Fish'; IDAPA 58.01.02.210.01.b) | IDAPA 58.01.02.210 Table 2 · p. 151 |
| 4.3; 8.0 µg/kg fish tissue µg/L | — | surface waters designated for primary or secondary contact recreation use (Table 2 'Fish Only'; IDAPA 58.01.02.210.01.b) inorganic arsenic, fish only: the water column element 4.3 µg/L; the fish tissue element 8.0 µg/kg wet weight supersedes it 90 days after any new activity or discharge (note k) | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Kind | Applies when | Cite |
|---|---|---|---|
| zero | guideline | 40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals. | 141.51, 141.62 |
| 0.010 mg/l | limit | 40 CFR 141.2: Maximum contaminant level means the maximum permissible level of a contaminant in water which is delivered to any user of a public water system. | as above |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Arsenic, Inorganic | 0.052 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Value | Applies when | Cite |
|---|---|---|
| 340 µg/L | receiving water: freshwater Freshwater CMC (acute): criterion maximum concentration, acute | National Recommended Aquatic Life Criteria tableArsenic (P) 7440382 340 150 69 36 1995 |
| 150 µg/L | receiving water: freshwater Freshwater CCC (chronic): criterion continuous concentration, chronic | as above |
| 69 µg/L | receiving water: marine Saltwater CMC (acute): criterion maximum concentration, acute | as above |
| 36 µg/L | receiving water: marine Saltwater CCC (chronic): criterion continuous concentration, chronic | as above |
| Value | Applies when | Cite |
|---|---|---|
| 0.018 µg/L | receiving water: freshwater consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns) | National Recommended Water Quality Criteria — Human Health Criteria TableArsenic (P) 7440382 0.018 0.14 1992 |
| 0.14 µg/L | receiving water: freshwater consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt) | as above |
| 0.14 µg/L | receiving water: marine consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt) | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Arsenic | 0.0028 Kg/kkg (or pounds per 1,000 lb) of product | daily maximum | discharge to surface water the discharge is of the Subpart AB—Boric Acid Production Subcategory existing sources (BPT) table: Subpart AB—Boric Acid Mined Borax Process | 40 CFR 415.282 (BPT)Arsenic 0.0028 0.0014 |
| Arsenic | 0.0014 Kg/kkg (or pounds per 1,000 lb) of product | monthly average | as above | as above |
| Arsenic (T) | 3.0 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart BO—Zinc Chloride Production Subcategory existing sources (BPT) table: Subpart BO—Zinc Chloride | 40 CFR 415.672 (BPT)Arsenic (T) 3.0 1.0 |
| Arsenic (T) | 1.0 mg/L | monthly average | as above | as above |
| Arsenic (T) | 3.0 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart BO—Zinc Chloride Production Subcategory existing sources (BAT) table: Subpart BO—Zinc Chloride | 40 CFR 415.673 (BAT)Arsenic (T) 3.0 1.0 |
| Arsenic (T) | 1.0 mg/L | monthly average | as above | as above |
| Arsenic (T) | 3.0 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart BO—Zinc Chloride Production Subcategory existing sources (PSES) table: Subpart BO—Zinc Chloride | 40 CFR 415.674 (PSES)Arsenic (T) 3.0 1.0 |
| Arsenic (T) | 1.0 mg/L | monthly average | as above | as above |
| Arsenic (T) | 3.0 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart BO—Zinc Chloride Production Subcategory new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart BO—Zinc Chloride | 40 CFR 415.675 (NSPS)Arsenic (T) 3.0 1.0. |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| .692 mg/kg (pounds per million pounds) of copper cast | daily maximum | (a) Subpart E—Casting Contact Cooling. | 40 CFR 421.53 (BAT)Arsenic .692 .309 |
| .309 mg/kg (pounds per million pounds) of copper cast | monthly average | as above | as above |
| .000 mg/kg (pounds per million pounds) of cathode copper production | daily maximum | (b) Subpart E—Anode and Cathode Rinse. | 40 CFR 421.53 (BAT)Arsenic .000 .000 |
| .000 mg/kg (pounds per million pounds) of cathode copper production | monthly average | as above | as above |
| .068 mg/kg (pounds per million pounds) of copper cathode production | daily maximum | (c) Subpart E—Spent Electrolyte. | 40 CFR 421.53 (BAT)Arsenic .068 .031 |
| .031 mg/kg (pounds per million pounds) of copper cathode production | monthly average | as above | as above |
| .000 mg/kg (pounds per million pounds) of casting production | daily maximum | (d) Subpart E—Casting Wet Air Pollution Control. | 40 CFR 421.53 (BAT)Arsenic .000 .000 |
| .000 mg/kg (pounds per million pounds) of casting production | monthly average | as above | as above |
| .000 mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing | daily maximum | (e) Subpart E—By-Product Recovery. | as above |
| .000 mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing | monthly average | as above | as above |
All 322 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Arsenic, total | 18 µg/L | daily maximum | (g) FGD wastewater —(1) 2020 BAT. (i) Except for those discharges to which paragraph (g)(2) or (3) of this section applies, the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 5 to this paragraph (g)(1)(i). Dischargers must meet the effluent limitations for FGD wastewater in this … table: Table 5 to Paragraph ( g )(1)( i ) | 40 CFR 423.13 (BAT)Arsenic, total (µg/L) 18 8 |
| Arsenic, total | 8 µg/L | monthly average | as above | as above |
| Arsenic, total | 11 µg/L | daily maximum | (ii) For FGD wastewater discharges from a high FGD flow facility, the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 6 to this paragraph (g)(2)(ii). Dischargers must meet the effluent limitations for FGD wastewater in this paragraph (g)(2)(ii) by a date determined by the permitti… table: Table 6 to Paragraph ( g )(2)( ii ) | 40 CFR 423.13 (BAT)Arsenic, total (µg/L) 11 8 |
| Arsenic, total | 8 µg/L | monthly average | as above | as above |
| Arsenic, total | 5 µg/L | daily maximum | (3) Voluntary incentives plan. (i) For dischargers who voluntarily choose to meet the effluent limitations for FGD wastewater in this paragraph (g)(3)(i), the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 7 to this paragraph (g)(3)(i). Dischargers who choose to meet the effluent… table: Table 7 to Paragraph ( g )(3)( i ) | 40 CFR 423.13 (BAT)Arsenic, total (ug/L) 5 NA |
| Arsenic, total | 11 µg/L | daily maximum | (iv) For FGD wastewater discharged from any coal combustion residual surface impoundment which commences closure pursuant to 40 CFR 257.102(e) after July 8, 2024, the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 8 to this paragraph (g)(4)(iv). table: Table 8 to Paragraph ( g )(4)( iv ) | 40 CFR 423.13 (BAT)Arsenic, total (µg/L) 11 8 |
| Arsenic, total | 8 µg/L | monthly average | as above | as above |
| Arsenic, total | 4 µg/L | daily maximum | (j)(1)(i) Gasification wastewater. Except for those discharges to which paragraph (j)(2) of this section applies, the quantity of pollutants in gasification wastewater shall not exceed the quantity determined by multiplying the flow of gasification wastewater times the concentration listed in the table following this paragraph (j)(1)(i). Dischargers must meet the effluent limitations in this pa… | 40 CFR 423.13 (BAT)Arsenic, total (ug/L) 4 |
| Arsenic, total | 11 µg/L | daily maximum | (iv) For bottom ash transport water discharged from any coal combustion residual surface impoundment which commences closure pursuant to 40 CFR 257.102(e) after July 8, 2024, the quantity of pollutants in bottom ash transport water shall not exceed the quantity determined by multiplying the flow of bottom ash transport water times the concentration listed in table 10 to this paragraph (k)(4)(iv). table: Table 10 to Paragraph (k)(4)(iv) | 40 CFR 423.13 (BAT)Arsenic, total (µg/L) 11 8 |
| Arsenic, total | 8 µg/L | monthly average | as above | as above |
All 35 rows from 40 CFR Part 423 — Steam electric power generating point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 4 mg/L | daily maximum | the discharge is of the Subpart G—Wood Preserving Steam Subcategory table: Subpart G [PSES Effluent Limitations] | 40 CFR 429.85 (PSES)Arsenic 4 |
| .41 | daily maximum | the discharge is of the Subpart G—Wood Preserving Steam Subcategory table: [Grams per cubic meter of production] | 40 CFR 429.85 (PSES)Arsenic .41 |
| 4 mg/L | daily maximum | the discharge is of the Subpart H—Wood Preserving—Boulton Subcategory table: Subpart H [PSES Effluent Limitations] | 40 CFR 429.95 (PSES)Arsenic 4 |
| .41 | daily maximum | the discharge is of the Subpart H—Wood Preserving—Boulton Subcategory table: Subpart H [PSES Effluent Limitations; grams per cu m of production] | 40 CFR 429.95 (PSES)Arsenic .41 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.162 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)Arsenic 0.162 0.104 |
| 0.104 mg/L | monthly average | as above | as above |
| 0.0993 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)Arsenic 0.0993 0.0199 |
| 0.0199 mg/L | monthly average | as above | as above |
| 2.95 mg/L | daily maximum | the discharge is of the Subpart B—Oils Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.21 (BPT)Arsenic 2.95 1.33 |
| 1.33 mg/L | monthly average | as above | as above |
| 0.162 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | 40 CFR 437.42 (BPT)Arsenic 0.162 0.104 |
| 0.104 mg/L | monthly average | as above | as above |
| 0.162 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | as above |
| 0.104 mg/L | monthly average | as above | as above |
All 34 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| As | 1.0 mg/L | daily maximum | the discharge is of the Subpart C—Uranium, Radium and Vanadium Ores Subcategory (b) The concentrations of pollutants discharged from mills using the acid leach, alkaline leach or combined acid and alkaline leach process for the extraction of uranium, radium and vanadium including mill-mine facilities and mines using in-situ leach methods shall not exceed: | 40 CFR 440.32 (BPT)As 1.0 .5 |
| As | .5 mg/L | monthly average | as above | as above |
| As | 1.0 mg/L | daily maximum | the discharge is of the Subpart F—Tungsten Ore Subcategory (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed: | 40 CFR 440.62 (BPT)As 1.0 .5 |
| As | .5 mg/L | monthly average | as above | as above |
| As | 1.0 mg/L | daily maximum | the discharge is of the Subpart F—Tungsten Ore Subcategory (c) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by purely physical methods including ore crushing, washing, jigging, heavy media separation, and magnetic and electrostatic separation shall not exceed: | as above |
| As | .5 mg/L | monthly average | as above | as above |
| As | 1.0 mg/L | daily maximum | the discharge is of the Subpart F—Tungsten Ore Subcategory (d) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by froth flotation methods shall not exceed: | as above |
| As | .5 mg/L | monthly average | as above | as above |
| As | 1.0 mg/L | daily maximum | the discharge is of the Subpart G—Nickel Ore Subcategory (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of nickel bearing ores per year shall not exceed: | 40 CFR 440.72 (BPT)As 1.0 .5 |
| As | .5 mg/L | monthly average | as above | as above |
All 26 rows from 40 CFR Part 440 — Ore mining and dressing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 84 µg/L | daily maximum | discharge to surface water existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)Arsenic 84 72 |
| 72 µg/L | monthly average | as above | as above |
| 84 µg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Pretreatment Standards 1 | 40 CFR 444.16 (PSES)Arsenic 84 72 |
| 72 µg/L | monthly average | as above | as above |
| Value | Statistic | Cite |
|---|---|---|
| 1.1 mg/L | daily maximum | 40 CFR 445.11 (BPT)Arsenic 1.1 0.54 |
| 0.54 mg/L | monthly average | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Arsenic (T) | 2.09 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: Subpart B—Electronic Crystals BPT Effluent Limitations | 40 CFR 469.24 (BPT)Arsenic (T) 2 2.09 0.83 |
| Arsenic (T) | 0.83 mg/L | monthly average | as above | as above |
| Arsenic | 2.09 mg/L | daily maximum | discharge to surface water existing sources (BAT) table: Subpart B—Electronic Crystals BAT Effluent Limitations | 40 CFR 469.25 (BAT)Arsenic 2 2.09 0.83 |
| Arsenic | 0.83 mg/L | monthly average | as above | as above |
| Arsenic (T) | 2.09 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Subpart B—Electronic Crystals PSES Effluent Limitations | 40 CFR 469.26 (PSES)Arsenic (T) 3 2.09 0.83 |
| Arsenic (T) | 0.83 mg/L | monthly average | as above | as above |
| Arsenic(T) | 2.09 mg/L | daily maximum | discharge to surface water new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): table: Subpart B—Electronic Crystals NSPS Effluent Limitations | 40 CFR 469.27 (NSPS)Arsenic(T) 3 2.09 0.83 |
| Arsenic(T) | 0.83 mg/L | monthly average | as above | as above |
| Arsenic (T) | 2.09 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) (a) table: Subpart B—Electronic Crystals PSNS Effluent Limitations | 40 CFR 469.28 (PSNS)Arsenic (T) 3 2.09 0.83 |
| Arsenic (T) | 0.83 mg/L | monthly average | as above | as above |
| Value | Applies when | Cite |
|---|---|---|
| 5.0 mg/L | (a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section. | 40 CFR 261.24, Table 1D004 Arsenic 7440-38-2 5.0 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 5.0 mg/L TCLP | instantaneous | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standardArsenic 7440-38-2 1.4 5.0 mg/l TCLP |
| Parameter | Value | Kind | Applies when | Cite |
|---|---|---|---|---|
| Arsenic, Inorganic | 0.68 mg/kg | guideline | Resident Soil (mg/kg) | source |
| Arsenic, Inorganic | 3 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
| Arsenic, Inorganic | 0.0015 mg/kg | guideline | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Arsenic, Inorganic | 0.29 mg/kg | reference value (not a limit) | Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.4 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standardArsenic 7440-38-2 1.4 5.0 mg/l TCLP |
This page shows 90 of 467 rows: every instrument, each with its first 10 rows or all of them. All 467 as JSON, 200 a page.
69 instruments we hold for Idaho (US-ID) and United States, for 23 names matching “arsenic” (each in the JSON). 17 have a row, in the tables above; 52 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the arsenic limits in Idaho? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=arsenic&place=US-ID; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.