Passage Data · Cited limits by place · Use it from your AI

O&G in Georgia (US-GA): 40 CFR Part 465 — Coil coating point source category

12 rows for o&g in this instrument. Every instrument for o&g in Georgia

United States (US): 12 rows

Effluent: 12 rows

40 CFR Part 465 — Coil coating point source category · eCFR as of 2026-10-05 · 12 limits
Every row: discharge to surface water
ParameterValueStatisticApplies whenCite
Oil and grease55.1 mg/m² (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart A—Steel Basis Material Subcategory
existing sources (BPT)
table: Subpart A
40 CFR 465.11 (BPT)
Oil and grease 55.1 (11.3) 33.1 (6.77)
Oil and grease33.1 mg/m² (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
Oil and grease3.16 mg/m² (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart A—Steel Basis Material Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
table: Subpart A
40 CFR 465.13 (NSPS)
Oil and grease 3.16 (0.65) 3.16 (0.65)
Oil and grease3.16 mg/m² (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
Oil and grease52.2 mg/m (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart B—Galvanized Basis Material Subcategory
existing sources (BPT)
table: Subpart B
40 CFR 465.21 (BPT)
Oil and grease 52.2 (10.7) 31.3 (6.42)
Oil and grease31.3 mg/m (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
Oil and grease3.43 mg/m (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart B—Galvanized Basis Material Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a new source subject to the provisions of this subpart:
table: Subpart B
40 CFR 465.23 (NSPS)
Oil and grease 3.43 (0.71) 3.43 (0.702)
Oil and grease3.43 mg/m (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
Oil and grease67.3 mg/m (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart C—Aluminum Basis Material Subcategory
existing sources (BPT)
table: Subpart C
40 CFR 465.31 (BPT)
Oil and grease 67.3 (13.8) 40.4 (8.27)
Oil and grease40.4 mg/m (pounds per 1 million ft ) of area processedmonthly averageas aboveas above
Oil and Grease4.75 mg/m² (pounds per 1 million ft ) of area processeddaily maximumthe discharge is of the Subpart C—Aluminum Basis Material Subcategory
new sources (NSPS)
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart.
table: Subpart C
40 CFR 465.33 (NSPS)
Oil and Grease 4.75 (0.98) 4.75 (0.98)
Oil and Grease4.75 mg/m² (pounds per 1 million ft ) of area processedmonthly averageas aboveas above