Passage Data · Cited limits by place · Use it from your AI
8 cited rows from 3 instruments, Florida's own first. Not covered: a permit's own limits, or rules outside the 70 instruments we hold for Florida (US-FL) and United States. Everything held for Florida
Florida: surface water 4 · United States: drinking water 1, soil 3
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene) | < 0.0028 annual avg. µg/L | annual average | receiving water: freshwater Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.) | F.A.C. 62-302.530(57)(a) · p. 42 |
| Polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene) | < 0.031 annual avg. µg/L | annual average | receiving water: marine Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.) | as above |
| Polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene) | < 0.031annual avg. µg/L | annual average | receiving water: freshwater Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III) | as above |
| Polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene) | < 0.031 annual avg. µg/L | annual average | receiving water: marine Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III) | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| ~Perylene | 1.8 µg/L | Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024 | source |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| ~Perylene | 5.4 mg/kg | Resident Soil (mg/kg) | source |
| ~Perylene | 67 mg/kg | Industrial Soil (mg/kg) | as above |
| ~Perylene | 2.2 mg/kg | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
70 instruments we hold for Florida (US-FL) and United States, for 5 names matching “perylene” (each in the JSON). 3 have a row, in the tables above; 67 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the perylene limits in Florida? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=perylene&place=US-FL; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.